ANADIGICS AWS5518

AWS5518
GaAs IC
SPDT Reflective Switch DC-2.0 GHz
PRELIMINARY DATA SHEET - Rev 1.0
FEATURES
•
•
•
•
•
•
High Linearity (IP3 48 dBm @ 0.9 GHz)
Low Insertion Loss (0.4 dB @ 0.9 GHz)
2.7 V to 6 V Operation
Low DC Power Consumption
Ultra Miniature SOT-26 Package
High Isolation
APPLICATIONS
•
•
•
Transmit/Receive Switch
Diversity Switching
Antenna Selection
S14
SOT-26
6 Pin Plastic Package
PRODUCT DESCRIPTION
The AWS5518 is a Single Pole Double Throw (SPDT)
GaAs MMIC switch assembled in a SOT-26 plastic
package. The AWS5518 is designed for applications
that require low insertion loss, high isolation, high
linearity, and small size. The switch can be controlled
with positive, negative, or a combination of both voltages.
Table 1: Pin Description
Vs
C3
RFOUT1
(J2)
1
6
2
5
3
4
V1
PIN
Optional Rs
see Note 3
2
GND
C1
RF OUT2
(J3)
1
3
RFIN
(J1)
4
V2
C2
5
Figure 1: Pinout Diagram
6
NAME
DESCRIPTION
RFOUT 2 (J3) RF port (can be used as an input or as an output)
GND
Ground connection (keep as short as possible)
RFOUT 1 (J2) RF port (can be used as an input or an ouput)
V1
Control voltage 1 ( Low 0 V, High 2.7 V to 5 V)
RFcommon port and bias voltage for positive
RFIN (J1)/Vs
control (3 V to 5 V)
V2
Control voltage 2 (Low 0 V, High 2.7 V to 5 V)
Notes:
1. DC blocking capacitors C1,2,3 and optional resistor Rs
must be supplied externally.
2. C1,2,3 = 100 pF for operation >500 MHz.
3. The use of resistor Rs to the positive voltage supply is
optional. It is only required if it is necessary to independently
control the RF ports, such as selecting both ports to be OFF
at the same time.
03-2002
AWS5518
ELECTRICAL CHARACTERISTICS
Table 2: Absolute Minimum and Maximum Ratings
PARAMETER
MIN
MAX
UNIT
-
6
W
Control Voltage
-0.2
+8
V
Operating Temperature
-40°
+85
°C
Storage Temperature
-65
+150
°C
-
25°
C/W
RF Input Power
> 900 MHz, V Control
θJC
Stresses in excess of the absolute ratings may cause permanent damage.
Functional operation is not implied under these conditions. Exposure to
absolute ratings for extended periods of time may adversely affect reliability.
Table 3: Operating Ranges at 25° C
PARAMETER
CONDITION
Switching Characteritics (2)
Rise, Fall (10/90% or 90/10% RF)
On, Off (50% CTL to 90/10% RF)
Video Feedthru
Intermodulation Intercept Point (IP3)
2-tone power levels 13dBm to 27dBm
MIN
TYP
MAX
UNIT
100
100
100
nS
nS
mV
+48
+46
+61
+56
dB m
dB m
dB m
dB m
+28
+27
+37
+37
dB m
dB m
dB m
dB m
-75
dB c
(selected to optimize dynamic range of test)
VCTL = 2.7 V
VCTL = 5.0 V
Input power for 1dB Compression
FREQUENCY
VCTL = 2.7 V
VCTL = 5.0 V
Harmonic Level
Input power = +30 dBm, VCTL = 5.0 V
Control Voltage (VCTL)(3)
Nominal operation voltage
Leakage Current
VCTL = 2.7 V
VCTL = 5.0 V
1.0
1.8
1.0
1.8
GHz
GHz
GHz
GHz
1.0
1.8
1.0
1.8
GHz
GHz
GHz
GHz
+45
+42
+55
+52
1 & 1.8 GHz
2.7
6
V
50
75
µA
µA
The device may be operated safely over these conditions; however, parametric performance is guaranteed only over
the conditions defined in the electrical specifications.
Notes:
1. All measurements made in a 50 Ohm system, unless other specified.
(2) Video feedthru measured with 1 ns rise time pulse and 500 MHz bandwidth.
(3) VCTL is the absolute value of the differential voltage from V1 to V2. Changing polarity selects the switch path as defined
in the truth table below. Use of the optional resistor Rs on the common port limits VHIGH to Vs ±0.2 V.
2
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
AWS5518
Table 4: Electrical Specifications at 25 °C
(VCTL = 2.7 V)
PARAMETER
Insertion Loss
FREQUENCY (2)
(1)
MIN
DC - 1.0 GHz
DC - 2.0 GHz
(3)
Isolation
DC - 1.0 GHz
DC - 2.0 GHz
VSWR(3)
0.5 - 2.0 GHz
25
22
TYP
MAX
UNIT
0.35
0.45
0.45
0.55
dB
32
24
dB
1.4:1
dB
Notes:
(1) All measurements made in a 50 Ω system, unless other specified.
(2) DC = 300 kHz
(3) In low insertion loss path.
Table 5: Truth Table
Positive Operation
V1
V2
J1 - J2
J1 - J3
VHigh
V Low
Isolation
L o w L o ss
V Low
VHigh
L o w L o ss
Isolation
VHigh = 2.7 to 5 V (Vs = VHigh ± 0.2 V)
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
3
AWS5518
PERFORMANCE DATA
Figure 2: Insertion Loss vs. Frequency
1.0
Figure 3: Isolation vs. Frequency
0
0.9
-5
0.8
-10
-15
0.6
Isolation (dB)
Insertion Loss (dB)
0.7
0.5
0.4
0.3
-20
Input to Output Isolation
-25
-30
0.2
0.1
-35
0.0
0.5
1.0
1.5
2.0
Output to Output
Isolation
-40
2.5
Frequency (GHz)
-45
0.5
1.0
1.5
2.0
2.5
Frequency (GHz)
Isolation vs Frequency
Figure 4: VSWR vs. Frequency
1.4
60
TOI (dBm)
1.3
VSWR
Figure 5: TOI vs. Control Voltage
65
1.2
55
50
1.0GHz
1.8GHz
1.1
45
1.0
0.5
1.0
1.5
Frequency (GHz)
4
2.0
2.5
40
2.5
3
3.5
4
Control Voltage (V)
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
4.5
5
AWS5518
PACKAGE OUTLINE
SYMBOLS
DIMENSIONS IN MILLIMETERS
DIMENSIONS IN INCHES
MIN
MAX
1.30
1.00
0.00
0.10
0.70
0.90
0.50
0.35
0.25
0.10
3.10
2.70
1.80
1.40
1.90(TYP)
3.00
2.60
0.37
9°
1°
MIN
MAX
0.051
0.039
0.00
0.004
0.027
0.035
0.014
0.020
0.004
0.010
0.122
0.106
0.055
0.071
0.075(TYP)
0.102
0.118
0.015
9°
1°
A
A1
A2
b
C
D
E
e
H
L
1
NOTE
1. PACKAGE BODY SIZES EXCLUDE MOLD FLASH
AND GATE BURRS
2. DIMENSION L IS MEASURED IN GAGE PLANE
3. COPLANARITY : 0.1000 mm
4. TOLERANCE ±0.1000 mm(4 mil) UNLESS
OTHERWISE SPECIFIED
Figure 6: S14 Package Outline Diagram
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
5
AWS5518
NOTES
6
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
AWS5518
NOTES
PRELIMINARY DATA SHEET - Rev 1.0
03/2002
7
AWS5518
ORDERING INFORMATION
ORDER NUMBER
PACKAGE DESCRIPTION
COMPONENT PACKAGING
AWS5518S14
S 14
6 Pin Plastic Package
ANADIGICS, Inc.
35 Technology Drive
Warren, New Jersey 07059
Tel: +1 (908) 668-5000
Fax: +1 (908) 668-5132
URL: http://www.anadigics.com
E-mail: [email protected]
IMPORTANT NOTICE
ANADIGICS, Inc. reserves the right to make changes to its products or to discontinue any product at any time without notice.
The product specifications contained in Advanced Product Information sheets and Preliminary Data Sheets are subject to
change prior to a product’s formal introduction. Information in Data Sheets have been carefully checked and are assumed to be
reliable; however, ANADIGICS assumes no responsibilities for inaccuracies. ANADIGICS strongly urges customers to verify
that the information they are using is current before placing orders.
WARNING
ANADIGICS products are not intended for use in life support appliances, devices, or systems. Use of an ANADIGICS product
in any such application without written consent is prohibited.
8
PRELIMINARY DATA SHEET - Rev 1.0
03/2002