ARTESYN NLP65

NLP65-3300J
Single output
LOW POWER AC/DC POWER SUPPLIES
•
•
•
•
•
•
•
33 W AC/DC Universal Input Switch Mode Power Supplies
1
5.0 x 3.0 inch card and 1.26 inch package (1U applications)
EN61000-3-2 compliance option (HCC)
Overvoltage and short circuit protection
EN55022, EN55011 conducted emissions level B
EN61000-4-2, -3, -4, -5, -6 immunity compliant
Enclosure and cover kit options
Available RoHS compliant
The NLP65-3300J is a 33 W universal input ac-dc power supply on a 5 x 3 inch card with a
maximum component height of 1.26 inches for use in 1U applications. This model has the
option of input harmonic current correction in the same package size making the series ideal
for product designs that will need to comply with EN61000-3-2 legislation. The NLP65-3300J
provides 33 W of output power with free air convection cooling. The NLP65, with full
international safety approval and the CE mark, meets conducted emissions EN55022 level B
and has immunity compliance to EN61000-4-2, -3, -4, -5, -6. The series is available in a
factory installed enclosure with an IEC connector and output connector on flying leads plus a
cover kit for self-installation is also available as an accessory. The NLP65 series is designed
for use in low power data networking, computer and telecom applications such as hubs,
routers, POS terminals, internet servers, cable modems and PABX’s. This list is not exclusive
as the generic feature set of the NLP65 series with industry standard output configurations
provides a solution for most low power applications including many industrial applications.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Total regulation
Line and load
Rise time
At turn-on
Transient response
Main output
25% step
at 0.1 A/µs
±3.0% max.
1.0 s, max. @ 230 Vac
5.0% or 165 mV
max. dev., 1 ms max.
recovery to 1%
Conducted emissions
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
(4, 10)
EN55022, FCC part 15, (Note 3) Level B
EN55022, FCC part 15
Level A
EN61000-4-2, level 3
Perf. criteria 1
EN61000-4-2, level 4
Perf. criteria 1
EN61000-4-5, level 3
Perf. criteria 1
EN61000-4-4, level 3
Perf. criteria 1
EN61000-4-3, level 3
Perf. criteria 2
EN61000-4-6, level 3
Perf. criteria 2
Temperature coefficient
±0.02%/°C
Overvoltage protection
125%, ±10%
GENERAL SPECIFICATIONS
Yes, indefinite
Hold-up time
Short circuit protection
Minimum output current
Cyclic operation
Single
(See Note 6)
INPUT SPECIFICATIONS
Input voltage range
(See Note 1)
Nominal
85-264 Vac
120-370 Vdc
Input frequency range
47-63 Hz
Input surge current
(cold start)
120 Vac
230 Vac
Safety ground
leakage current
120 Vac, 60 Hz
230 Vac, 50 Hz
Inrush current
230 Vac
Input current
120
230
120
230
Input fuse
UL/IEC127
Vac,
Vac,
Vac,
Vac,
17 A max.
32 A max.
0.7 mA
1.4 mA
32 A max.
with PFC
with PFC
without PFC
without PFC
0.5
0.25
0.7
0.4
A
A
A
A
rms
rms
rms
rms
250 Vac S 3.15 A
230 Vac, 50 Hz
Efficiency
64% typical
Isolation voltage
Input/output
Input/chassis
Switching frequency
Fixed
Approvals and
standards
(See Notes 9 and 11)
3000 Vac
1500 Vac
100 kHz, ±5 kHz
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
EN41003 (BABT)
Weight
MTBF
78 ms @ 33 W
283 g (10 oz)
MIL-HDBK-217F
150,000 hours min.
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Notes 1 and 2)
Operating temperature 0 °C to +50 °C
Non-operating
-40 °C to +85 °C
50 °C to 70 °C ambient,
0.65 W/°C
convection cooled
Peak (0 °C to +50 °C, 60 s)
See table
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 5)
5-500 Hz
Shock
per MIL-STD-810E
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4 G rms peak
516.4 Part IV
File Name: nlp65-3300j.pdf Rev (02): 08 Nov 2005
NLP65-3300J
Single output
LOW POWER AC/DC POWER SUPPLIES
33 W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT
OUTPUT
RIPPLE
VOLTAGE
MAX
PEAK
+3.3 V
10 A
13 A
(3)
(2)
50 mV
±99 mV
Notes
N
1
8
2
3
4
5
6
7
TOTAL
OVP
REGULATION
When the input voltage is less than 90 Vac the operating temperature
range is 0 °C to +40 °C. The ripple and regulation specifications may not
be met.
Peak output current lasting less than 60 seconds with duty cycle less than
5%. During peak loading, output voltage may exceed total regulation limits.
Figure is peak-to-peak for convection power rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch
twisted pair, terminated with a 10 µF electrolytic capacitor and a 0.1 µF
ceramic capacitor.
For EMI compliance, the unit must be used in a system application where
the earth pads are connected to a metal chassis.
Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
rms 5 Hz to 500 Hz.
To maintain stated regulation then:
I ≥ 1.0 A
For optimum reliability, no part of the heatsink should exceed 120 ºC, and
no semiconductor case temperature should exceed 130 ºC.
9
10
11
12
13
MODEL
NUMBER
125%, ±10%
(12,13)
NLP65-3300J
CAUTION: Allow a minimum of 1 second after disconnecting line power
when making thermal measurements.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
For system EMI compliance, a ground choke may be required before
connecting the ground wire to the chassis. It is recommended that, when
used, this ground choke be placed as close as possible to the systems ac
inlet to eliminate noise pick-up in the system.
Require a minimum mounting stand-off of 0.25 inches (6.35 mm) in the end
use product.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
12A
11A
10A
20CFM FORCED AIR COOLING
50ºC
9A
8A
7A
6A
70ºC
NATURAL
CONVECTION
COOLING
5A
4A
3A
2A
1A
0°C 10°C
20°C
30°C
40°C
50°C
60°C
70°C
File Name: nlp65-3300j.pdf Rev (02): 08 Nov 2005
NLP65-3300J
Single output
LOW POWER AC/DC POWER SUPPLIES
33 W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
5.00
(127.00)
4.550
(115.57)
J1
3 N
0.225
(5.715)
J3
1
1 L
3.00
(76.20)
6
2.550
(64.770)
T1
J2
C19
Mounting
Hole Diameter
0.156 (4.00)
PIN
Pin 1
Pin 2
Pin 3
Pin 1
INPUT
CONNECTIONS
J1
AC Line
No Pin
AC Neutral
J2
Safety Ground
ALL DIMENSIONS IN INCHES (mm)
OUTPUT PIN CONNECTIONS
J3
SINGLE
Pin 1
Vout
Pin 2
Vout
Pin 3
Vout
Pin 4
Return
Pin 5
Return
Pin 6
Return
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
TOLERANCE: .xxx ± 0.005"
.xx ± 0.02"
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 type.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J3) connector type
Molex 26-60-4060 type.
DC (J3) mating connector type
Molex 09-50-3061 with Triurcon 6838
or equivalent crimp terminals.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 10401-3336-1096
Licence No. 93678
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Designed to meet, approval pending
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: nlp65-3300j.pdf Rev (02): 08 Nov 2005