ARTESYN NLS110-9602

NLS110-9602
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
1
•
•
•
•
•
7.0 x 4.25 x 1U package
Overvoltage and short circuit protection
110W with 20CFM
90VAC to 264VAC universal input range
EN55022 conducted emissions level B, radiated
emissions level A
• UL, VDE and CSA safety approvals
• CE mark
The NLS110-9602 is a 110W universal input AC/DC power supply on a 7 x 4.25 inch
card. The NLS110-9602 has proven itself to be highly reliable and versatile product for
a wide range of communication and industrial applications, with a very high peak
current capability on each output for drive and motor applications. The NLS110-9602
provides 80W of output power with free air convection cooling which can be boosted to
110W with 20CFM of air. Standard features include overvoltage and short circuit
protection. The NLS110-9602 with full international safety approval and the CE mark,
meets conducted emissions EN55022 level B. The NLS110-9602 is designed for use in
low power data networking, computer, telecom and industrial applications such as
servers, thermal printers, storage devices, vending machines and POS equipment.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
Line and load
Rise Time
At turn-on
(See table)
(See table)
Temperature coefficient
±0.02%/°C
Overvoltage protection
+5.1V
125%, ±10%
Short circuit protection
Cyclic operation
Yes with auto
recovery
35ms @ 80W
25ms @ 110W
Efficiency
120VAC @ 110W
70% min.
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Approvals and
standards
Universal input
90 to 264VDC
Input frequency range
47Hz to 440Hz
Input surge current
(cold start)
120VAC
230VAC
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
Input current
120VAC
120VAC
230VAC
230VAC
Input fuse
UL/IEC127
EMC CHARACTERISTICS
0.95A
1.35A
0.53A
0.75A
(11)
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level B
Level A
Compliant
Level
Level
Level
Level
Level
Level
3
3
3
3
3
3
(6,8)
Operating ambient,
0°C to +50°C
(see derating curve)
Non-operating
–40°C to +85°C
+50°C to +70°C,
Derate to
amb. convection cooled
50% load
0°C to +50°C,
80W
amb. convection cooled
0°C to +50°C ambient,
110W
150LFM forced air
Peak (0°C to +50°C, 60s) (See Note 4)
Relative humidity
Non-condensing
Altitude
Operating
Non-operating
Vibration (See Note 7)
5Hz to 500Hz
Shock
per MIL-STD-810E
rms
rms
rms
rms
F3.15A H, 250VAC
220,000 hours min.
Thermal performance
0.45mA
0.75mA
80W
110W
80W
110W
383g (13.5 oz.)
MIL-HDBK-217F
ENVIRONMENTAL SPECIFICATIONS
18A max.
35A max.
@
@
@
@
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
Weight
MTBF (@ 25˚C)
INPUT SPECIFICATIONS
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
120VAC @ 60Hz
1.0s, max.
Transient response
Input voltage range
Hold-up time
5% to 95% RH
10,000 feet max.
30,000 feet max.
2.4G rms peak
516.4 Part IV
File Name: NLS110.PDF Rev: 12 June 2001
NLS110-9602
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
VOLTAGE
OUTPUT CURRENTS
MAX
(1)
PEAK
(2)
FAN
RIPPLE
(3)
TOTAL
REGULATION
(4)
+5.1V
8.0A
20.0A
10.0A
50mV
±2.0%
+24.0V
3.5A
4.5A
4.5A
240mV
±5.0%
+12.0V
4.5A
9.0A
5.0A
120mV
±3.0%
–12.0V
0.5A
1.5A
1.0A
120mV
±3.0%
Notes
NLS110-9602
(12)
TRANSIENT RESPONSE
1
2
Convection cooled, 80W maximum.
Peak outputs lasting less than 60 seconds with duty cycle less than 10%.
Total peak power must not exceed 110W.
3 Forced air, 20CFM at 1 atmosphere, 110W maximum.
4 Amplitude is peak-to-peak. Output ripple is measured across a 20MHz
bandwidth using a 12 inch twisted pair terminated with a 10µF capacitor.
5 Total regulation is defined as the static output regulation at 25°C, including
initial tolerance, line voltage within stated limits and output voltages
adjusted to their factory settings.
6 Derating curve is application specific for ambient temperatures >50°C.
7 Three orthogonal axes, random vibration, 10 minute test for each axis.
8 For optimum reliability no part of the heatsink should exceed 100oC and no
semiconductor case temperature should exceed 115oC.
9 Caution: Allow a minimum of 1 second after disconnecting the power when
making thermal measurements.
10 This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
11 The EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering is required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance. A line choke, (AC input cords
looped twice through an EMI suppression toroid) was used during radiated
emissions testing. Considerable radiated testing in 1U six-sided boxes has
shown that units can meet level B in typical systems. Application support
is available from the factory to assist with EMI compliance.
12 Requires a minimum mounting stand-off of 6.35mm (0.25 inches) in the end
use product.
OUTPUT PIN CONNECTIONS
J2
FUNCTION
Pin 1
+5.1V
Pin 2
+5.1V
Pin 3
Return
Pin 4
Return
Pin 5
Return
Pin 6
Return
Pin 7
+12V
Pin 8
+12V
Pin 9
+24V
Pin 10
PFD
Pin 11
-12V Return
Pin 12
-12V
MODEL NUMBERS
(5)
INPUT
PIN CONNECTIONS
J1
Pin 1
AC Neutral
Pin 2
No Connection
Pin 3
AC Line
J4
Pin 1
Safety Earth
NLS110-9602
+5.1V (7.5A to 10A)
+24V (1.5A to 3A)
+12V (2.5A to 5A)
-12V (0.5A to 1A)
150mV peak,
1ms recovery
300mV peak,
1ms recovery
100mV peak,
0.5ms recovery
100mV peak,
0.5ms recovery
DERATING CURVE
Output Power (Watts)
110W
150 LFM FORCED
AIR COOLING
80W
NATURAL
CONVECTION
COOLING
55W
40W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM
AC INPUT
5V OUTPUT
4.75V
4.75V
HIGH
3.5V MIN
LOW
PFD SIGNAL
0-0.4 MAX
Please consult our website for the following items: ✔ Application Note
T3
T1
T2
Power fail detect signal
50ms≤T1≤200ms
T2 will vary with line and load
T3≥3ms
Pout: 110W
PFD output is an open collector
which will sink ≤40mA in the low
state.
www.artesyn.com
File Name: NLS110.PDF Rev: 12 June 2001
NLS110-9602
Quad output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 80-110W AC/DC Universal Input Switch Mode Power Supplies
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Mechanical Notes
A All dimensions are in inches (mm).
2
7.00 (177.80)
6.500 (165.100)
4
3
J4
1
T1 (REF)
12
4.25
(107.95)
T2 (REF)
3.750
(95.250)
Recommended direction
for forced air relative to
power supply orientation
shown below.
1
2
3
4
J2
F1
Optimum.
Very good.
Not recommended.
Not recommended.
1
3
J1
1
0.25 (6.35)
0.25 (6.35)
J5
2
1
TOLERANCE: .XXX: ±0.005 (0.127)
.XX: ±0.02 (0.51)
ALL DIMENSIONS IN INCHES (mm)
Input and output connectors
Mating connectors
AC (J1) connector type
Molex 26-60-4030 or equivalent.
AC (J1) mating connector type
Molex 09-50-3031 or equivalent with Molex
08-50-0105 or equivalent crimp terminals.
DC (J2) connector type
12 position Molex Spox type 26-48-1125
or equivalent.
DC (J2) mating connector type
Molex Spox type 26-03-3121 and
contact 08-52-0113.
Earth (J4) connector type
Male 0.250 quick disconnect.
Earth (J4) mating connector type
Molex 90028.
International Safety Standard Approvals
VDE0805/EN60950/IEC950/IEC1010 File No. 10401-3336-1049
Licence No. 2874, 1653 and 1049
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Application Note
www.artesyn.com
File Name: NLS110.PDF Rev: 12 June 2001