AXTAL AXIOM30HP

Issue: 01
Date: 2006-06-31
Specification
AXIOM30HP
Oscillator type :
High-performance OCXO in CO15 package
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature (steady state)
operating temperature range
vs. supply voltage variation
vs. load change
long term (aging) per day
long term (aging) 1st year
long term (aging) per 15 years after
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC input impedance
RF output
Signal waveform
Load
Output level
Harmonics
Warm-up time @25°C
Phase noise
min.
typ.
Oscillator Enable input (pin 6)
Unit
Condition
Note 2
± 20
± 5
+70
± 0.5
± 0.5
± 0.5
± 30
± 500
MHz
MHz
ppm
ppb
ppb
°C
ppb
ppb
ppb/day
ppb
ppb
10.000
-20
±1
0
2.5
Positive
5
100
@VC= VREF/2 ± 10%
@+40°C, after 30 days
@+40°C, after 30 days
ppm
V
kΩ
Sinusoidal
50
+5
5
Short term stability (Allan variance)
Reference Voltage Output
Oven alarm output (pin 2)
max.
+10
-20
105
-100
-130
-145
-150
-150
-150
5·10-12
1·10-11
1·10-10
5.0
LOW = alarm (not stable)
HIGH = ready
LOW = Oscillator OFF
HIGH = Oscillator ON
11.4
12
12.6
100
Ω
dBm
dBc
min
dBc
dBc
dBc
dBc
dBc
dBc
± 10 %
∆ffinal/f0 < ±10 ppb
@ 1Hz
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 10 kHz
@ 100 kHz
τ=1s
τ = 10 s
τ = 100 s
V
0 … 0.4 V
2.4 … 5 V
HCMOS compatible
V
Supply voltage VS
mA
Current consumption
(steady state, @ +25°C)
Current consumption (warm-up)
340
mA
-40
+85
°C
Storage temperature range
20.5x20.5x12 max.
mm
IEC 60679-3 CO15-7
Enclosure (see drawing)
10
gram
Weight
Palette
IEC 60286-3
Packing
1500
V
HBM IEC 61000-4-2
ESD Sensitivity
Notes:
1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM30HP
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing:
Pin connections
Pin # Symbol
1
RF OUT
2
OA
3
GND
4
VREF
5
VC
6
OE
7
VS
Function
RF Output
Oven Alarm Output
Ground
Reference Voltage
Control Voltage (EFC)
Oscillator Enable Input
Supply Voltage
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM30HP
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]