AXTAL AXIS10

Issue: 03
Specification
AXIS10
Oscillator type :
SMD VCXO in CO 26 package
Parameter
min.
Frequency range
Standard frequencies
Frequency stability
Initial tolerance
vs. temperature in operating
temperature range (steady state)
vs. supply voltage variation
vs. load change
long term (aging) per year
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
EFC linearity
EFC input impedance
RF output
Signal waveform
Output signal HIGH
VOH
Output signal LOW
VOL
typ.
max.
1.544
100
16.384/19.440/38.880/52.000
-20
20
±5
-3
-1
± 100
0.5
0.3
Date: 2005-06-10
Unit
Condition
MHz
MHz
ppm
ppm
ppm
See Note 1
3
1
±1
ppm
VS ±5%
ppm
Load ±5%
ppm/year @ 40°C
4.5
3.0
ppm
V
V
positive
10
Option I = ”50”
Option I = “33”
%
kΩ
100
HCMOS
2.4
VS-0.5V
0.4
0.5
10
Rise & decay time
Symmetry (duty cycle)
Start-up time
Supply voltage VS
40
Current consumption (steady state)
Operating temperature range
Operable temperature range
Storage temperature range
Enclosure (see drawing) (LxWxH)
Weight
Packing
ESD Sensitivity
60
10
4.75
5.0
5.25
3.13
3.3
3.47
45
85
-20
+70
-40
+85
-45
+90
-55
+105
14.4 x 9.5 x 5.5 max
3
Tape & reel
1500
V
V
V
V
ns
%
ms
V
V
mA
mA
°C
°C
°C
°C
mm
gram
V
TTL load (fan-out 2)
HCMOS load 15 pF
TTL load (fan-out 2)
HCMOS load 15 pF
according to logic
family
@ VS/2
Option I = “50”
Option I = “33”
Option I = “50”
Option I = “33”
Option II = “2070”
Option II = “4085”
IEC 61837 CO 27
IEC 60286-3
HBM as in IEC 610004-2
Notes:
1. Frequency stability = initial tolerance + stability vs. temperature
2. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification)
AXIS10
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
Option I
33
Option II
2070
Frequency [MHz]
52.000
AXIS10
page 1(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections
Pin # Symbol
1
VC
2*
N.C.
3
GND
4
RF OUT
5*
N.C.
6
Vs
Function
Control Voltage (EFC)
No Connection
Ground
RF Output
No Connection
Supply Voltage
* Note: Pins 2 and 5 may not be present
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
IEC 60679-1
clause ...
4.3
2-17
4.6.2
2-20
2-58
4.6.3
2-27
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
temperature
Dry heat
2-14
4.6.5
2-2
4.6.14
Damp heat, cyclic*
2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence*
1-7
4.6.17
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-3
4.6.18
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIS10
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]