CUI VD-120B

•
VD-120B Dual Output Switching Power Supply
Features
·Low cost, high reliability
·105°C output capacitor
·Universal AC input range
·High efficiency, low temperature rise
·Soft-start circuit, limiting AC surge current
·Short circuit, overload, over-voltage protected
·Compact size, light weight
·100% full load burn-in test
·Buil-in EMI filter, low ripple noise
CH1
DC output voltage
Output V. tolerance
Output rated current
Output current range
Ripple & noise
Line regulation
Load regulation
DC output power
Efficiency
DC voltage adj.
Input voltage range
AC current
Inrush current
Leakage current
Overload protection
Over voltage protection
Temperature coefficient
Set up, rise, hold up time
Vibration
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
Weight
Safety standards
EMC standards
Notes:
CH2
5V
24V
±2%
±7%
6A
4A
2-10A
0.4-4A
60mVp-p
150mVp-p
±0.5%
±1.0%
±0.5%
±6.0%
120W
78%
CH1:+10,-5%
88~132VAC/176~264VAC selected by switch, 47~63Hz; or 248~370VDC
2.5A/115V 1.25A/230V
cold start 35A
<3.5mA/240VAC
105%~135% shutoff
AC recycle to restart
CH1:5.75V~6.75V
±0.03% / ºC (0~50ºC) ON +5V output
200ms, 50ms, 20ms
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
7.83x4.33x1.97inches (199x110x50mm)
1.94lbs. (0.88Kgs)
UL1950, TUV EN60950
CISPR22 (EN55022) CLASS B, IEC801-2,3,4, IEC555-2 verification
1. All parameters are specified at 230VAC input, rated load, 25°C 70% ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 0% to 100% rated load
6. Each output provides up to maximum current, but total load can not exceed max. output power
7. C2, C3, C11 must be removed
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258
•
VD-120B Dual Output Switching Power Supply
Block Diagram
Output Derating
Static Characteristics
Dimensions (mm)
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258