CUI VDSD2-S12-DI9-DIP

1/3
VDSD2-DIP Series DC-DC Converter
Rev. 06-2006
Description
Features
Designed to convert fixed voltages into an isolated voltage, the
VDSD2-DIP series is well suited
for providing board-mount local
supplies in a wide range of applications, including mixed
analog/digital circuits, test &
measurement equip.,
process/machine controls, datacom/telecom fields, etc...
·Isolated 2 W output
·Temperature range: -40°C~+85°C
·Unregulated
·High efficiency to 87%
·Dual independent voltage output
·Small footprint
·DIP package style
·Industry standard pinout
·UL94-V0 package
·No heatsink required
·1K Vdc isolation
·No external component required
·Low cost
The semi-regulated output can be
followed by 3-terminal regulators
to provide output protection, in
addition to output regulation.
Model
Number
VDSD2-S5-DI5-DIP
VDSD2-S5-DI9-DIP
VDSD2-S5-DI12-DIP
VDSD2-S5-DI15-DIP
VDSD2-S12-DI5-DIP
VDSD2-S12-DI9-DIP
VDSD2-S12-DI12-DIP
VDSD2-S12-DI15-DIP
VDSD2-S24-DI5-DIP
VDSD2-S24-DI9-DIP
VDSD2-S24-DI12-DIP
VDSD2-S24-DI15-DIP
Input Voltage
Nominal
Range
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
5 Vdc
4.5~5.5 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
12 Vdc
10.8~13.2 Vdc
24 Vdc
21.6~26.4 Vdc
24 Vdc
21.6~26.4 Vdc
24 Vdc
21.6~26.4 Vdc
24 Vdc
21.6~26.4 Vdc
Output
Voltage
5, 5 Vdc
9, 9 Vdc
12, 12 Vdc
15, 15 Vdc
5, 5 Vdc
9, 9 Vdc
12, 12 Vdc
15, 15 Vdc
5, 5 Vdc
9, 9 Vdc
12, 12 Vdc
15, 15 Vdc
Output
Max.
200, 200 mA
112, 112 mA
84, 84 mA
67, 67 mA
200, 200 mA
112, 112 mA
84, 84 mA
67, 67 mA
200, 200 mA
112, 112 mA
84, 84 mA
67, 67 mA
Current
Package
Min.
Efficiency Style
20, 20 mA
82%
DIP
12, 12 mA
83%
DIP
9, 9 mA
85%
DIP
7, 7 mA
85%
DIP
20, 20 mA
83%
DIP
12, 12 mA
84%
DIP
9, 9 mA
86%
DIP
7, 7 mA
86%
DIP
20, 20 mA
84%
DIP
12, 12 mA
85%
DIP
9, 9 mA
87%
DIP
7, 7 mA
87%
DIP
Output Specifications
Item
Test conditions
Output power
Line Regulation
Load Regulation
Output voltage accuracy
For Vin change of 1%
10% to 100% full load
See tolerance envelope graph
Temperature drift
Output ripple
Switching frequency
100% load
20 MHz Bandwidth
Full load, nominal input
Min.
Typ.
0.2
100
75
Max.
Units
2
1.2
15
W
%
%
0.03
200
%/°C
mVp-p
KHz
Note:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless
otherwise specified.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
2/3
VDSD2-DIP Series DC-DC Converter
Rev. 06-2006
General Specifications
Short circuit protection
Temperature rise at full load
1 second
25°C Max, 15°C Typ.
Cooling
Free air convection
Operating temperature range
-40°C to +85°C
Storage temperature range
-55°C to +125°C
Soldering temperature
300°C (1.5mm from case for 10 sec.)
Storage humidity range
<95%
Case material
Plastic (UL94-V0)
safety
approved to UL60950-1 (E222736)
MTBF
>3,500,000 hrs.
Burn-in
Full load at +85°C, for 4 hours at no-load and 4 hours at full load.
Isolation Specifications
Item
Isolation Voltage
Insulation Resistance (Vin/Vout)
Insulation Resistance (Vout1/Vout2)
Test Conditions
Tested for 1 min.
Test at 500 Vdc
Test at 500 Vdc
Min.
1000
1000
1000
Typ.
Max.
Units
Vdc
MΩ
MΩ
Typical Characteristics
Output Current (%)
Ambient Temperature ( C )
Outline Dimensions &
Recommended Layout Pattern
Pin
1
7
14
11 10 9 8
1
7
8
9
10
11
14
-Vin
NC
+Vout2
-Vout2
+Vout1
-Vout1
+Vin
14
11 10
1
9 8
7
Note: All Pins on a 2.54mm pitch; All Pin diameters are 0.50 mm; all dimensions in mm.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
3/3
VDSD2-DIP Series DC-DC Converter
Rev. 06-2006
- Minimum loading
Application Notes:
The converter needs a minimum of 10% loading to
maintain output regulation. Operation under no-load
- Input filtering
To reduce the reflected ripple current and minimize
conditions will not cause immediate damages but
EMI, especially when the converter input is more
may reduce reliability, and cause performance not to
than 2” away from the DC source, it is recommended
meet specifications.
to connect a low ESR electrolytic capacitor between
Vin and Gnd. The values suggested are as shown in
- Regulation
Table 1. If additional filtering is required, the
With a semi-regulated design, the converter’s output
capacitance may be increased, or expanded to an LC
voltage varies with load current and will change
network as shown in Figure 1.
proportionally to the input voltage. If regulated
output is needed, an external regulator can be used
Table 1
as shown in Figure 2.
- Protection
Input Voltage
External Input Capacitance
5V
4.7 µF
over-voltage or output over-load, and may be
12 V
2.2 µF
permanently damaged if exposed to these conditions.
24 V
1.0 µF
The converter has minimal protection against input
An input clamping device can be used for input
voltage limiting. An input fuse or an output fuse
can also be used to protect against over-loading.
- Output filtering
- External Regulator
An output capacitor is needed to meet output ripple
An external 3-terminal regulator can be connected
requirements as shown in Table 2.
to the output of the converter to achieve full
Output capacitance may be increased for additional
regulation. Make sure the converter’s output voltage
filtering, but should not exeed 10µF or expanded to
provides sufficient head room for the regulator. An
an LC network as in Figure 1.
additional benefit is that the built-in protection
features in the regulator, such as OCP, OTP, etc, will
Table 2
protect the converter also. In a complimentory
supply, a negative output regulator must be used to
Vout
External Ouput Capacitance
5V
4.7 µF
9V
2.2 µF
12 V
+Vout1
+Vin
1.0 µF
15 V
achieve the negative regulated output.
REG
-Vout1
DC DC
+Vout2
-Vin
0.47 µF
-Vout2
REG
+Vout1
REG
+Vout2
+Vin
L
+Vout1
L
C
+Vin
C
DC DC
-Vin
-Vout1
DC DC
L
C
-Vin
-Vout2
-Vout1
+Vout2
(Figure 2)
-Vout2
(Figure 1)
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com