CUI VMF05-S090

rev.
page
1 of 2
date
08/2007
DESCRIPTION: open frame AC/DC power supply
PART NUMBER: VFM05 series
features
·universal input: 85~264VAC
·efficiency at 77% typical
·meets UL/cUL, TUV, CE
·conductive EMI meets
CISPR/FCC, Class B
·single output
model
number
VFM05-S033
VFM05-S050
VMF05-S090
VFM05-S120
VFM05-S180
VFM05-S150
VFM05-S240
output
voltage
3.3 V
5.0 V
9.0 V
12 V
18 V
15 V
24 V
output current
min. rated max.
0A
1.25 A
0A
1.0 A
0A
0.55 A
0A
0.42 A
0A
0.28 A
0A
0.33 A
0A
0.23 A
ripple 1
(mVp-p)
50 mV
50 mV
90 mV
120 mV
180 mV
150 mV
240 mV
voltage
accuracy
±1%
±1%
±1%
±1%
±1%
±1%
±1%
line
reg. 2
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
INPUT
voltage
frequency
inrush current
isolation
leakage current
85-264 Vac
47 to 63 Hz
40 A max. @ 264 Vac
input to output = 4,242VDC
0.25mA max.
OUTPUT
hold up time
8mS typ. @ 115VAC
short circuit protection
temperature coefficient
continuous
±0.05% / °C
GENERAL & SAFETY
operating temperature
storage temperature
approvals
emmisions
0° - 70°C (see derating curve)
-20° - +85°C
UL60950, TUV, CE
CISPR/FCC Class B
MECHANICAL OUTLINE
dimensions
2.17x1.38x0.83(max) inches
(55x35x21mm 3 )
NOTES:
1. add a 0.1µF ceramic capacitor and a 10µF E.L. capacitor to output for ripple and noise measuring @20MHz BW.
2. line regulation is measured from 100VAC to 240VAC with full load.
3. load regulation is measured from 60% to 100% full load and from 60% to 20% full load (60% ±40% full load).
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
load
reg. 3
±1%
±1%
±1%
±1%
±1%
±1%
±1%
rev.
DIMENSIONS (mm)
(
)
Tolerances: .xx ± .02(.xx ± .5) unless otherwise noted.
-Vo
1.28 (32.48)
2.17 (55.00)
0.07 (1.78)
0.15 (3.70)
0.17 (4.40)
0.04 (1.02)
1.85 (47.00)
0.83 (21.00)max
VR
2.01 (51.01)
0.1 (2.60)
0.2 (5.01)
0.16 (4.01)
0.49 (12.47)
+Vo
ACL
0.06 (1.60)
0.89 (22.50)
1.38 (35.00)
ACN
DERATING CURVE
100%
75%
-6.667%/˚C
25%
20LFM(Natural Convection)
0%
0
10
20
30
40
2 of 2
date
08/2007
DESCRIPTION: open frame AC/DC power supply
PART NUMBER: VFM05 series
50%
page
50
60
70
80
90
Ambient Temperature(˚C)
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382