ETC SD250-1

Document 130-1
Base/GateDriverTransformers
• Lower cost than toroidal equivalents
• Frequency range of 10 - 250 kHz and up
• Industry standard pin centers
• VDE, IEC, UL, CSA compatible
• 3750 VRMS isolation between windings
• UL approved Class 130°C insulation system
available (UL File E83628)
Coilcraft Designer’s Kit No. P204 contains samples of 4 standard driver transformers. To order,
please contact Coilcraft or visit http://order.coilcraft.com to order on-line.
STANDARDVERSIONSPECIFICATIONS
DRIVE WINDING
Inductance (Min)1
Leakage inductance (Max)1
DCR
Volt-time product
SD250-1
1.5 mH
4.0 eH
0.4h
375 V-esec
SECONDARY WINDING(S)
Np/Ns (± 3%)
Cap., drive to sec. (Max)
DCR each section (Max)
SD250-2
1.5 mH
4.0 eH
0.4h
375 V-esec
1:1
50 pF
.75h
1 : 1.5
50 pF
2.5h
SD250-1 and 250-2
SD250-3
1.5 mH
4.0 eH
0.4h
375 V-esec
1:1:1
50 pF
.75h
SD250-4
1.5 mH
4.0 eH
0.4h
375 V-esec
1
10
Drive
5
Sec
6
SD250-3 and 250-4
7
Sec 1
6
10
1
Drive
5
1 : 1.5 : 1.5
50 pF
2.5h
Sec 2
9
1. Measured at 1 Vrms, 15.75 kHz
2. Operating temperature range –40° C to +85° C.
3. Electrical specifications at 25° C.
1.10
Max.
27,94
0.350
8,89
1
1.10
Max.
27,94
0.950
Max.
24,13
0.400
10,16
5
0.62 ± 0.015
15,75 ± 0,38
0.395
Max.
10,03
10
0.15 ± 0.030
3,81 ± 0,762
6
0.40
10,16
0.032
Diameter Ref.
0,813
0.20
5,08
0.80
20,32
(Pins 7 and 9 omitted on SD250-1 and 250-2)
Specifications subject to change without notice.
Document 130-1 Revised 9/14/00
Document 130-2
CUSTOMVERSIONSPECIFICATIONS
In addition to the standard base/gate driver transformers shown here, Coilcraft can provide custom
versions to meet your specifications.
Our two basic structures are the .95″ high part shown and a 1.20″ high version. Both are available with
either single or double sections.
Please use the information below to determine the performance characteristics available.
CORE
Initial permeability
Ae (core cross-sectional area)
le (mean magnetic path length)
.95″ high bobbins
1.20″ high bobbins
2000µ
0.40 cm2
4.90 cm
2000µ
0.80 cm2
4.80 cm
BOBBIN
Specifications subject to change without notice.
Document 130-2 Revised 11/12/97