LEM LF205-S_06

Current Transducer LF 205-S
IPN
=
200 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16135
Electrical data
IPN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance @
with ± 12 V
with ± 15 V
ISN
KN
VC
IC
@ ± 200 A max
@ ± 420 A max
@ ± 200 A max
@ ± 420 A max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption @ ± 15 V
200
0 .. ± 420
TA = 70°C
TA = 85°C
RM min RM max RM min RM max
0
0
0
0
71
14
100
28
0
0
23
23
69
12
98
26
100
1 : 2000
± 12 .. 15
17 + I S
A
A
• Closed loop (compensated) current
transducer using the Hall effect
Ω
Ω
Ω
Ω
mA
V
mA
Accuracy - Dynamic performance data
XG
ε
Overall accuracy @ IPN , TA = 25°C
Linearity error
L
± 0.5
< 0.1
IO
IOM
IO T
Typ Max
Offset current @ IP = 0, TA = 25°C
± 0.2
Residual current 1) @ IP = 0, after an overload of 3 x IPN
± 0.1
Thermal drift of IO
- 40°C .. + 85°C
± 0.12 ± 0.4
tra
tr
di/dt
f
Reaction time @ 10 % of IPN
Response time 2) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 3 dB)
< 500
<1
> 100
DC .. 100
%
%
mA
mA
mA
ns
µs
A/µs
kHz
m
Notes :
2)
according to UL 94-V0.
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
• Switched Mode Power Supplies
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 70°C
@ TA = 85°C
Mass
Standards
1)
• Insulated plastic case recognized
(UPS)
General data
TA
TS
RS
Features
- 40 .. + 85
°C
- 40 .. + 90
°C
33
Ω
35
Ω
78
g
EN 50178 : 1997
(SMPS)
• Power supplies for welding
applications.
Application domain
• Industry.
The result of the coercive field of the magnetic circuit
With a di/dt of 100 A/µs.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
060522/11
Page 1/3
w w w .lem.com
Current Transducer LF 205-S
Isolation characteristics
Vd
Vw
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Impulse withstand voltage 1.2/50 µs
3.5
8.8
kV
kV
Ve
R.m.s. voltage for partial discharge extinction @ 10pC
>2
kV
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group III a)
Min
11
10.2
175
mm
mm
Application examples
According to EN 50178 and IEC 61010-1 standards and following conditions :
• Over voltage category OV 2
• Pollution degree PD3
• Non-uniform field
EN 50178
IEC 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
500 V
500 V
Reinforced isolation
250 V
250 V
dCp, dCI, Vw
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
060522/11
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
Page 2/3
w w w .lem.com
Dimensions LF 205-S
(in mm. 1 mm = 0.0394 inch)
Bottom view
Front view
Right view
Back view
Connection
Top view
Mechanical characteristics
Remarks
• General tolerance
• Transducer fastening
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
Vertical position
Fastening torque, max
or
• Transducer fastening
Horizontal position
Fastening torque, max
or
Fastening torque, max
• Primary through-hole
• Connection of secondary
± 0.2 mm
2 holes ∅ 4.3 mm
2 M4 steel screws
3.2 Nm or 2.37 Lb. - Ft.
4 holes ∅ 1.9 mm depth 7 mm
4 x PT KA25 screws long 6 mm
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
4 holes ∅ 4.3 mm
4 M4 steel screws
3.2 Nm or 2.37 Lb. - Ft.
4 holes ∅ 1.9 mm
4 x PT KA25 screws
0.7 Nm or 0.52 Lb. - Ft.
∅ 15.5 mm
Molex 5045-0.3/A
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
060522/11
Page 3/3
w w w .lem.com