LRC SB2045

SB2020 thru SB20100
Schottky Barrier Rectifiers
Reverse Voltage 35 to 100V Forward Current 20A
Feature & Dimensions
* Plastic package has underwriters laboratory
Flammability classification 94V-0
* Low power loss,high efficiency
* For use in low voltage high frequency inverters,
free wheeling,and polarity protection applications
* Guarding for over voltage protection
* High temperature soldering guaranteed:
260°C/10 seconds at terminals
Mechanical Data
Case
: JEDEC R-6, molded plastic over sky die
Terminals : Plated axial leads, solderable per
MIL-STD-750, Method 2026
Polarity
: Color band denotes cathode end
We declare that the material of product compliance
Weight
: 0.042oz., 1.19 g
with ROHS requirements
Mounting position
: Any
Handling precautin : None
1.Maximum & Thermal Characteristics Ratings at 25°C ambient temperature unless otherwise specified.
Parameter symbol
Symbol
Device marking code
SB2035 SB2045 SB2050 SB2060 SB2080 SB20100
Unit
SB2035 SB2045 SB2050 SB2060 SB2080 SB20100
Maximum repetitive peak reverse voltage
VRRM
35
45
50
60
80
100
V
Maximum RMS voltage
VRMS
35
45
50
60
80
100
V
Maximum DC blocking voltage
VDC
35
45
50
60
80
100
V
Maximum average forward rectified current
0.375" (9.5mm) lead length (See fig. 1)
IF(AV)
20.0
A
IFSM1
230
A
40
°C/W
–40 to +150
°C
Peak forward surge current 8.3ms single half sine-wave
superimposed on rated load (JEDEC Method)
Thermal resistance, junction to ambient
Operating junction and storage temperature range
RθJA
TJ, TSTG
Electrical Characteristics Ratings at 25°C ambient temperature unless otherwise specified.
Parameter symbol
Symbol
Maximum instantaneous forward voltage at 20.0A
VF
Maximum DC reverse current
Ir
TC = 25°C
Maximum DC reverse current
TC = 100°C
Typical junction capacitance at 4.0V, 1MHz
Ir
CJ
SB2035 SB2045 SB2050 SB2060 SB2080 SB20100
0.55
0.60
0.70
0.90
200
uA
1000
500
Unit
V
uA
380
Notes:
1. Thermal resistance from junction to ambient at 0.375” (9.5mm) lead length, P.C.B. mounted
PF
SB2020 thru SB20100
2. Characteristic Curves ( TA = 25°C unless otherwise noted )
20
10
0
0
25
50 75 100 125 150 175
Ambient Temperature, °C
Fig 3. – Typical Instantaneous Forward
Characteristics
100
10
1.0
TJ = 25°C
Pulse width = 300µs
1% Duty Cycle
0.1
100
0.4
0.6
0.8
1.0
Instantaneous Forward Voltage (V)
Fig 5. –typical transient thermal
impedance
200
100
0
1
10
Number of Cycles at 60Hz
100
10
1.0
Tj=100℃
0.1
Tj=75℃
Tj=25℃
0.001
0
20
40
60
80
100
Percent of Rated Peak Reverse Voltage (%)
1.2
Fig 6. – Typical Junction Capacitance
1000
1.0
0.1
0.1
1.0
10
t,Pulse duration,sec
TJ = TJ max
8.3ms Single Half Sine-wave
(JEDEC Method)
0.01
10
0.01
Fig. 2 – Maximum Non-repetitive Peak
Forward Surge Current
Fig 4. – Typical Reverse Characteristics
Junction Capacitance (pF)
Transient thermal impedance(°C/W)
0.01
0.2
Average Forward Rectified Current (A)
Single phase
half wave 60HZ
Resistive or
Inductive Load
0.375" (9.5mm)
lead length
250
Instantaneous Reverse Current (mA)
Instantaneous Forward Current (A)
Average Forward Rectified Current (A)
Fig. 1 – Forward Current Derating Curve
100
100
1.0
0.1
1
10
Reverse Voltage (V)
100
SB2020 thru SB20100
3. dimension:
R-6
0.335
0.375
8.5
9.5
SB2020 thru SB20100
4. Update Record
版次
更新记录
更新作者
更新日期
1
第一版
周杰