MEANWELL PLN-30

PLN-30
30W Single Output LED Power Supply
series
Features :
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Fully isolated plastic case with IP64 level
Built-in active PFC function
IP64 design for indoor or outdoor installations
Pass LPS
Class
power unit, no FG
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
F
110
LPS
( except for 48V )
( for 48V only)
PLN-30-9
PLN-30-12
PLN-30-15
PLN-30-20
PLN-30-24
PLN-30-27
PLN-30-36
PLN-30-48
9V
12V
15V
20V
24V
27V
36V
48V
8.4 ~ 12V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
2A
1.5A
1.25A
1.12A
0.84A
0.63A
M
M
SELV
( except for 48V )
IP64
SPECIFICATION
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V
OUTPUT
RATED CURRENT
3.3A
2.5A
CURRENT RANGE
0 ~ 3.3A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.5A
0 ~ 1.25A
0 ~ 1.12A
0 ~ 0.84A
0 ~ 0.63A
RATED POWER
29.7W
30W
30W
30W
30W
30.24W
30.24W
30.24W
2Vp-p
2.6Vp-p
2.6Vp-p
2.6Vp-p
2.3Vp-p
4.5Vp-p
3.7Vp-p
RIPPLE & NOISE (max.) Note.2 2.6Vp-p
VOLTAGE ADJ. RANGE Note.5 -5% ~ 10%. Can be adjusted by internal potentiometer SVR1
CURRENT ADJ. RANGE Note.5 3% ~ -25%. Can be adjusted by internal potentiometer SVR2
VOLTAGE TOLERANCE Note.3
10%
LINE REGULATION
3.0%
5.0%
LOAD REGULATION
1500ms / 230VAC 3000ms / 115VAC at full load
SETUP TIME
VOLTAGE RANGE
INPUT
Note.4 90 ~ 295VAC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
80%
82.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
0.4A/115VAC
40A/230VAC
0.2A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
OVER CURRENT
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
SAFETY &
EMC
OTHERS
83.5%
84%
84%
84.5%
85%
85.5%
40 ~ 50V
53 ~ 63V
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
10 ~ 14V
14 ~ 16V
17 ~ 22V
23 ~ 26V
27 ~ 34V
31 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
95
10
(TSW1)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.06%/
, 10 ~ 95% RH
(0 ~ 50
)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL879, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V) ; J61347-1, J61347-2-13, IP64 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C (pin
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria A
MTBF
621.4Khrs min. MIL-HDBK-217F (25
145*47*30mm (L*W*H)
0.22Kg; 60pcs/14.2Kg/1.25CUFT
DIMENSION
PACKING
NOTE
127 ~ 417VDC
FREQUENCY RANGE
25W), Class D (>70% load) ; EN61000-3-3
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLN-30-SPEC 2011-07-27
PLN-30
30W Single Output LED Power Supply
Mechanical Specification
Case No.964A
series
Unit:mm
145
320 20
2-R2.25
23.5
47
320 20
AC/L(Brown)
AC/N(Blue)
+V(Red)
-V(Black)
61
SVT 18AWG 2C
9.83
9.83
4.38
T case
SVT 18AWG 2C
4.38
30
T case: Max. Case Temperature.
Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2
shown in the diagram.
SVR2
SVR1
SVR1 Output voltage adjustment
SVR2 Output current adjustment
Block Diagram
fosc : 39KHz(115VAC)
53KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
40
AMBIENT TEMPERATURE ( )
50
60
60
50
40
90
100
125
135
145
155 165
175
180
200
230
295
INPUT VOLTAGE (V) 60Hz
File Name:PLN-30-SPEC 2011-07-27
PLN-30
30W Single Output LED Power Supply
series
Power Factor Characteristic
PF
Constant Current Mode
1
0
0
0
0
0
0
0
0
0
0
0
.0
.9
.9
.9
.9
.9
.8
.8
.8
.8
.8
.7
0
8
6
4
2
0
8
6
4
2
0
8
2 7 7 V ac
2 3 0 V ac
1 1 5 V ac
5 0 %
6 0 %
7 0 %
8 0 %
9 0 %
1 0 0 %
(30W)
LOAD
EFFICIENCY vs LOAD (48V Model)
EFFICIENCY (%)
PLN-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.
90
86
82
78
74
70
66
62
58
54
50
46
42
277Vac
230Vac
115Vac
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
70
(max.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:PLN-30-SPEC 2011-07-27