MEANWELL RSD-300

RSD-300
300W Railway Single Output DC-DC Converter
¡ ¡½
E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
¡E
series
Features :
Compliance to EN50155 railway certificate
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
4000VDC I/O isolation
SPECIFICATION
MODEL
OUTPUT
24V
48V
12V
24V
48V
12V
24V
48V
11.3A
5.7A
25A
12.5A
6.3A
25A
12.5A
6.3A
CURRENT RANGE
0 ~ 22.5A
0 ~ 11.3A
0 ~ 5.7A
0 ~ 25A
0 ~ 12.5A
0 ~ 6.3A
0 ~ 25A
0 ~ 12.5A
0 ~ 6.3A
RATED POWER
270W
271.2W
273.6W
300W
300W
302.4W
300W
300W
302.4W
150mVp-p
180mVp-p
120mVp-p
150mVp-p
180mVp-p
120mVp-p
150mVp-p
180mVp-p
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE TOLERANCE Note.3
Ó¡ 2.0%
¡Ó0.3%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.2%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.5%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.3%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.2%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.5%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.2%
Ó¡ 1.0%
Ó¡ 2.0%
¡Ó0.2%
Ó¡ 1.0%
SETUP, RISE TIME
800ms, 50ms at full load
HOLD UP TIME (Typ.)
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load ; D-type comply with S2 level @ full load
¡Ó2.0%
Ó¡ 0.5%
¡Ó1.0%
16.8 ~ 31.2VDC
33.6 ~ 62.4VDC
1 SEC.
EFFICIENCY (Typ.)
14.4 ~ 33.6VDC
28.8 ~ 67.2VDC
89%
90%
90%
91%
91%
91%
91%
91%
91%
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
14.6A/24V
14.6A/24V
14.6A/24V
7.2A/48V
7.2A/48V
7.2A/48V
3.1A/110V
3.1A/110V
3.1A/110V
CONTINUOUS
OVER TEMPERATURE
45A/110VDC
13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V 13.8 ~ 16.2V 27.6 ~ 32.4V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
B/C- type : 110
5 (TSW1) detect on main power transformer ; D-type : 115
¢J¡Ó ¢J
¢J¡Ó5¢J(TSW1) detect on main power transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
¢J (no derating) ; +70¢J @ 60% load by free air convection ; +70¢J no derating with external base plate, Tx class compliance
-40 ~ +55
20 ~ 95% RH non-condensing
ISOLATION RESISTANCE
57.6 ~ 154VDC
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
WORKING HUMIDITY
SAFETY STANDARDS
WITHSTAND VOLTAGE
67.2 ~ 143VDC
45A/48VDC
45A/24VDC
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
¢J
¡Ó0.03%/¢J (0 ~ 55¢J)
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
Meet IEC60950-1(LVD)
I/P-O/P:4KVDC
I/P-FG:2.5KVDC
O/P-FG:2.5KVDC
¢J
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Emission: Class A, Radiation Emission: Class B ; EN50155(EN50121-3-2)
EMC IMMUNITY
RAILWAY STANDARD
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A ; EN50121-3-2
Meet EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
MTBF
130.7K hrs min. MIL-HDBK-217F (25
216*97*40mm (L*W*H)
1.19Kg ; 12pcs/15.3Kg/1.12CUFT
DIMENSION
PACKING
NOTE
3 years warranty
12V
PROTECTION OVER VOLTAGE
OTHERS
100% full load burn-in test
22.5A
OVERLOAD
(Note 4)
¢J
LED indicator for power on
RATED CURRENT
VOLTAGE
RANGE
EMC
1U low profile 40mm
All using 105 long life electrolytic capacitors
RSD-300B-12 RSD-300B-24 RSD-300B-48 RSD-300C-12 RSD-300C-24 RSD-300C-48 RSD-300D-12 RSD-300D-24 RSD-300D-48
LOAD REGULATION
SAFETY &
Built-in constant current limiting circuit
DC VOLTAGE
LINE REGULATION
INPUT
Cooling by free air convection
¢J)
¢J
1. All parameters NOT specially mentioned are measured at 24,48,110VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:RSD-300-SPEC 2012-07-20
RSD-300
300W Railway Single Output DC-DC Converter
Mechanical Specification
Case No.205A
15max.
series
Unit:mm
2.1
40
2-R
28
15max.
4
208
216
4
7.75
208
LED
I/P
13
2
97
13
1
81
O/P
1
10
2
10
3
4-R2.1
Input Terminal Pin No. Assignment :
Pin No.
1
2
3
Assignment
DC INPUT V+
DC INPUT VFG
Output Terminal Pin No. Assignment :
Assignment
DC OUTPUT -V
DC OUTPUT +V
Pin No.
1
2
Block Diagram
fosc : 130KHz
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
FG
RECTIFIERS
&
FILTER
POWER
SWITCHING
O.L.P.
O.T.P.
+V
-V
DETECTION
CIRCUIT
PWM
CONTROL
O.V.P.
OUTPUT VOLTAGE (V)
100
80
No base plate
LOAD (%)
60
¡Ñ ¡Ñ
Have base plate
360 360 2mm
40
20
-40
0
10
20
30
40
50 55 60
¢J
AMBIENT TEMPERATURE ( )
70
(HORIZONTAL)
32
350
28
300
24
250
20
200
16
150
12
100
8
50
57.6
60
65
85
95
105
115
125
135
145
OUTPUT RIPPLE (mVp-p)
Static Characteristics(RSD-300D-24)
Derating Curve
154
INPUT VOLTAGE (V)
File Name:RSD-300-SPEC 2012-07-20
RSD-300
300W Railway Single Output DC-DC Converter
series
Input Fuse
There is one fuse connected in series to the positive input line, which are used to protect against abnormal surge. Fuse specifications of each model are shown as below.
Type
Fuse Type
Reference and Rating
B
Fast
Littelfuse 257, 30A, 32V
C
Time-Lag
Conquer UDA-A, 16A, 250V
D
Time-Lag
Conquer UDA-A, 8A, 250V
Input Reverse Polarity Protection
There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.
Input Under-voltage Protection
If input voltage drops to Vi min. -3V, the internal control IC shunts down and there is no output voltage.
Hold-up Time
D type is in compliance with S2 level, while B and C types are in compliance with S1 level at full load output condition. To fulfil the requirements of S2 level, B and C types require
de-rating their output load to 70%, please refer to the curve diagrams below.
B-24
0ms
10ms
20ms
30ms
40ms
50ms
60ms
70ms
B-48
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
80ms
LOAD
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
LOAD
LOAD
B-12
0ms
10ms
20ms
30ms
TIME
50ms
60ms
70ms
80ms
20ms
30ms
40ms
20ms
30ms
50ms
60ms
70ms
80ms
40ms
50ms
60ms
70ms
80ms
50ms
60ms
70ms
80ms
C-48
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
LOAD
LOAD
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
10ms
10ms
TIME
C-24
0ms
0ms
TIME
C-12
LOAD
40ms
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0ms
10ms
20ms
TIME
30ms
40ms
50ms
60ms
70ms
TIME
80ms
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0ms
10ms
20ms
30ms
40ms
TIME
Size of Base Panel
Unit:mm
M4*4
0
2
36
360
To fulfil the requirements of EN50155 TX level, RSD-300 series must be installed onto an iron plate on the bottom.
In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-300 series must be firmly mounted at the center of the iron plate, as
shown in the diagram above.
File Name:RSD-300-SPEC 2012-07-20
300W Railway Single Output DC-DC Converter
RSD-300
series
Immunity to Environmental Conditions
Test method
Standard
Test conditions
Status
Cooling Test
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40¢J
Dwell Time: 2 hrs/cycle
Dry Heat Test
EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX)
EN 60068-2-2
Temperature: 70¢J / 85¢J
Duration: 6 hrs / 10min
PASS
Damp Heat Test, Cyclic
EN 50155 section 12.2.5
EN 60068-2-30
Temperature: 25¢J~55¢J
Humidity: 90%~100% RH
Duration: 48 hrs
PASS
Vibration Test
EN 50155 section 12.2.11
EN 61373
Temperature: 19¢J
Humidity: 65%
Duration: 10 mins
PASS
Increased Vibration test
EN 50155 section 12.2.11
EN 61373
Temperature: 19¢J
Humidity: 65%
Duration: 5 hrs
PASS
Shock Test
EN 50155 section 12.2.11
EN 61373
Temperature: 21¡Ó 3¢J
Humidity: 65 ¡Ó 5%
Duration: 30ms*18
PASS
Low Temperature Storage Test
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40¢J
Dwell Time: 16 hrs
PASS
No damage
File Name:RSD-300-SPEC 2012-07-20