NSC CLC018AJVJQ

CLC018
8 x 8 Digital Crosspoint Switch, 1.4 Gbps
General Description
National’s Comlinear CLC018 is a fully differential 8x8 digital
crosspoint switch capable of operating at data rates exceeding 1.4 Gbps per channel. Its non-blocking architecture utilizes eight independent 8:1 multiplexers to allow each output
to be independently connected to any input and any input to
be connected to any or all outputs. Additionally, each output
can be individually disabled and set to a high-impedance
state. This TRI-STATE ® feature allows flexible expansion to
larger switch array sizes.
Low channel-to-channel crosstalk allows the CLC018 to provide superior all-hostile jitter of 50 psPP. This excellent signal
fidelity along with low power consumption of 850 mW make
the CLC018 ideal for digital video switching plus a variety of
data communication and telecommunication applications.
The fully differential signal path provides excellent noise immunity, and the I/Os support ECL and PECL logic levels. In
addition, the inputs may be driven single-ended or differentially and accept a wide range of common mode levels including the positive supply. Single +5V or −5V supplies or
dual +5V supplies are supported. Dual supply mode allows
the control signals to be referenced to the positive supply
(+5V) while the high-speed I/O remains ECL compatible.
The double row latch architecture utilized in the CLC018 allows switch reprogramming to occur in the background during operation. Activation of the new configuration occurs with
a single “configure” pulse. Data integrity and jitter performance on unchanged outputs are maintained during reconfiguration. Two reset modes are provided. Broadcast reset
results in all outputs being connected to input port DI0.
TRI-STATE Reset results in all outputs being disabled.
The CLC018 is fabricated on a high-performance BiCMOS
process and is available in a 64-lead plastic quad flat pack
(PQFP).
Features
n Fully differential signal path
n Non-Blocking
n Flexible expansion to larger array sizes with very low
power
n Single +5/−5V or dual ± 5V operation
n TRI-STATE outputs
n Double row latch architecture
n 64-lead PQFP package
Applications
n Serial digital video routing (SMPTE 259M)
n Telecom/datacom switching
n ATM SONET
Key Specifications
n High speed: > 1.4 Gbps
n Low jitter:
< 50 psPP for rates < 500 Mbps
< 100 psPP for rates < 1.4 Gbps
n Low power; 850 mW with all outputs active
n Fast output edge speeds: 250 ps
CLC018 Block Diagram
DS100088-1
DS100088-2
© 1998 National Semiconductor Corporation
DS100088
www.national.com
CLC018 8 x 8 Digital Crosspoint Switch, 1.4 Gbps
October 1998
Absolute Maximum Ratings (Note 1)
θJC 64-Pin PQFP
Reliability Information
Transistor Count
MTTF (based on limited life test data)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (VCC–VEE)
VLL Maximum
VLL Minimum
Storage Temperature Range
Lead Temp. (Soldering 4 sec.)
ESD Rating
Package Thermal Resistance
θJA 64-Pin PQFP
−0.3V to +6.0V
VCC +6V
VCC −0.5V
−65˚C to +150˚C
+260˚C
TBD
15˚C/W
3000
TBD
Recommended Operating
Conditions
Supply Voltage (VCC–VEE)
Operating Temperature
VLL
4.5V to 5.5V
−40˚C to +85˚C
VCC or VCC +5V
75˚C/W
Electrical Characteristics
(VCC = 0V, VEE = −5V, VLL = 0V; unless otherwise specified) (Note 4).
Parameter
Conditions
Typ
+25˚C
Min/Max
+25˚C
Min/Max
−40˚C to
+85˚C
Units
DYNAMIC PERFORMANCE
Max. Data Rate/Channel (NRZ)
(Note 5)
1.4
Gbps
Channel Jitter
Data Rate < 500 Mbps
(Note 6)
50
psPP
Data Rate < 1.4 Gbps
(Note 6)
100
psPP
Propagation Delay (input to output)
0.75
ns
Propagation Delay Match
(Note 7)
± 200
ps
Output Rise/Fall Time
(Note 8)
250
ps
Duty Cycle Distortion
(Note 9)
10
ps
CONTROL TIMING: CONFIGURATION
OA Bus to LOAD ↑ Setup Time (T1)
15
ns
LOAD ↓ to OA Bus Hold Time (T2)
0
ns
IA Bus, TRI to LOAD ↓ Setup Time (T3)
5
ns
LOAD ↓ to IA Bus, TRI Hold Time (T4)
5
ns
LOAD
10
ns
CNFG
10
ns
0
ns
Min Pulse Width: (T5)
LOAD ↑ to CNFG ↑ Delay (T6)
CNFG ↑ to Valid Delay (T7)
20
ns
CNFG ↑ to Output TRI-STATE Delay (T8)
20
ns
CNFG ↑ to Output Active Delay (T9)
70
ns
CONTROL TIMING: RESET (Note 11)
TRI to RES ↑ Setup Time (T10)
5
ns
RES ↓ to TRI Hold Time (T11)
5
ns
Min Pulse Width: RES (T12)
10
ns
RES ↑ to TRI-STATE Mode Delay (T13)
20
ns
RES ↑ to Broadcast Mode Delay (T14)
70
ns
STATIC PERFORMANCE
Signal I/O:
Min Input Swing, Differential
(Note 3)
150
200
200
mVPP
Input Voltage Range Lower Limit
−2
V
Input Voltage Range Upper Limit
0.4
V
Input Bias Current
(Notes 3, 12)
1.5
0.4/3.1
0.3/3.8
µA/output
Output Current
(Note 3)
10.7
8.53/12.80
7.20/14.3
mA
www.national.com
2
Electrical Characteristics
(Continued)
(VCC = 0V, VEE = −5V, VLL = 0V; unless otherwise specified) (Note 4).
Parameter
Conditions
Typ
+25˚C
Min/Max
+25˚C
Min/Max
−40˚C to
+85˚C
Units
800
640/960
540/1060
mV
Signal I/O:
RLOAD = 75Ω
Output Voltage Swing
Output Voltage Range Lower Limit
−2.5
V
Output Voltage Range Upper Limit
0
V
Control Inputs:
Input Voltage - HIGH
VIH
Input Voltage - LOW
VIL
Input Voltage - HIGH
VIH
Input Voltage - LOW
VIL
min
(Note 3)
−1
−0.5
−0.5
max
(Note 3)
−4
−4.5
−4.5
V
VLL = +5V (Note 3)
4
4.5
4.5
V
min
V
VLL = +5V (Note 3)
1
0.5
0.5
V
Input Current - HIGH
VIH = VLL (Note 3)
1
0.2/2.0
0.1/2.5
µA
Input Current - LOW
VIL = VLL −5V (Note 3)
−100
−200/10
−250/15
µA
VCC Supply Current
All Outputs Active
(Notes 3, 13, 14)
157
127/202
119/217
mA
VCC Supply Current
All Outputs TRI-STATE
(Note 3)
7
3/11
2/12
mA
VLL Supply Current
VLL = 0V (Note 3)
2.5
1.7/3.3
1.5/3.5
mA
VLL Supply Current
VLL = +5V (Note 3)
7
max
MISCELLANEOUS PERFORMANCE
Input Capacitance
Output Capacitance
mA
1.5
pF
2
pF
Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The table of “Electrical Characteristics” specifies conditions of device operation.
Note 2: Min/max ratings are based on product characterization and simulation. Individual parameters are tested as noted. Outgoing quality levels are determined
from tested parameters.
Note 3: J-level spec. is 100% tested at +25˚C.
Note 4: VLL and all VEE supply pins are bypassed with 0.01 µF ceramic capacitor.
Note 5: Bit error rate less than 10−9 over 50% of the bit cell interval.
Note 6: Measured using a pseudo-random (223−1 pattern) binary sequence with all other channels active with an uncorrelated signal.
Note 7: Spread in propagation delays for all input/output combinations.
Note 8: Measured between the 20% and 80% levels of the waveform.
Note 9: Difference in propagation delay for output low-to-high vs. output high-to-low transition.
Note 10: Refer to the Configuration Timing Diagram.
Note 11: Refer to the Reset Timing Diagram.
Note 12: The bias current for high speed data input depends on the number of data outputs that are selecting that input.
Note 13: The VCC supply current is a function of the number of active data outputs. IVCC 18*N + 7 mA where N is an integer from 0 to 8.
Note 14: IVEE = IVCC + IVLL.
3
www.national.com
Typical Performance Characteristics
DS100088-3
www.national.com
DS100088-4
DS100088-5
DS100088-6
DS100088-7
DS100088-8
4
Connection Diagram
DS100088-9
Order Number CLC018AJVJQ
See NS Package Number VJE64A
CONTROL PINS
IA2, IA1 and IA0 are the three bit input selection address
bus. The input port to be addressed is placed on this bus.
IA2 is the Most Significant Bit (MSB). If input port 6 is to be
addressed, IA2, IA1, IA0 should have 1, 1, 0 asserted on
them. The IA bus should be driven with CMOS levels, if VLL
is +5V. These levels are thus +5V referenced (standard
CMOS). If VLL is connected to GND, the input levels are referenced to the −5V and GND supplies.
OA2, OA1 and OA0 are the output selection address bus.
The output port selected by the OA bus is connected to the
input port selected on the IA bus when the data is loaded into
the configuration registers. OA2 is the MSB. If OA2, OA1,
OA0 are set to 0, 0, 1; then output port 1 will be selected.
CS is an active-high chip select input. When CS is high, the
RES, LOAD, and CNFG pins will be enabled.
LOAD is the latch control for the LOAD register. When LOAD
is high, the load register is transparent. Outputs follow the
state of the IA bus, and are presented to the inputs of the
Configuration register selected by the OA bus. When LOAD
is low, the outputs of the Load register are latched.
RES is the reset control of the configuration and load registers. A high-going pulse on the RES pin programs the switch
matrix to one of two possible states: with TRI low, all outputs
are connected to input #0; with TRI high, all outputs are put
in TRI-STATE condition.
TRI will program the selected output to be in a high impedance or TRI-STATE condition. To place an output in
TRI-STATE, assert a logic-high level on the TRI input when
the desired input and output addresses are asserted on the
respective address inputs and strobe the LOAD input as depicted in the ”Configuration Truth Table”. To enable an output, assert a logic-low level on the TRI input together with the
appropriate addresses and strobe the LOAD input as previously described.
CNFG is the configuration register latch control. When
CNFG is high the Configuration register is made transparent,
and the switch matrix is set to the state loaded into the Load
registers. When CNFG is low, the state of the switch matrix
is latched.
Pin Descriptions
POWER PINS
VCC is the most positive rail for the data path. When the data
levels are ECL compatible, then VCC should be connected to
GND. For PECL data (+5V referenced ECL), VCC is connected to the +5V supply. Please refer to the device operation section in this datasheet for recommendations on the
bypassing and ground/power plane requirements of this device.
VEE is the most negative rail for the data path. When the data
levels are ECL compatible, then VEE is connected to a −5.2V
power supply. For PECL data (+5V referenced ECL), VEE is
connected to GND.
VLL is the logic-level power supply. If the control signals are
referenced to +5V, VLL is connected to a +5V supply. If control signals are ECL compatible, VLL is connected to GND.
DATA INPUT PINS
DI0 and DI0 through DI7 and D17 are the data input pins to
the CLC018. Depending upon how the Power pins are connected (please refer to the Power Pin section above) the
data may be either differential ECL, or differential PECL. To
drive the CLC018 inputs with a single-ended signal, please
refer to the section “Using Single-Ended Data” in the OPERATION section of this datasheet.
DATA OUTPUT PINS
DO0 and DO0 through DO7 and DO7 are the data output
pins of the CLC018. The CLC018 outputs are differential current outputs which can be converted to ECL or PECL compatible outputs through the use of load resistors. Please refer to the “Output Interfacing” paragraph in the OPERATION
section of this datasheet for more details.
5
www.national.com
Timing Diagrams
DS100088-10
FIGURE 1. Timing Diagram — TRI-STATE Reset
DS100088-11
FIGURE 2. Timing Diagram — “Broadcast Reset”
www.national.com
6
Timing Diagrams
(Continued)
DS100088-12
FIGURE 3. Timing Diagram — Switch Configuration
Operation
INPUT INTERFACING
The inputs to the CLC018 are high impedance differential inputs (see the equivalent input circuit in Figure 4). The
CLC018 can be operated with either ECL or PECL (+5V referenced ECL), depending upon the power supply connections. The inputs are differential and must both be within the
range of VCC– 2V to VCC + 0.4V in order to function properly.
DS100088-13
FIGURE 4. Equivalent Input Circuit
SINGLE ENDED INPUTS
Differential inputs are the preferred method of providing data
to the CLC018, however, there are times when the only signal available is single ended. To use the CLC018 with a
single ended input, the unused input pin needs to be biased
at a point higher than the low logic level, and lower than the
high logic level. For best noise performance, the middle of
7
www.national.com
Operation
(Continued)
the range is best. For ECL signals this point is about 2 diode
drops below ground. It is possible to bias the unused input
with a low-pass filtered version of the data, as shown in Figure 5. In some coding schemes there are pathological patterns that result in long sequences with no data transitions.
During these patterns, the bias on the unused input will drift
towards the other input reducing the noise immunity which
makes this scheme undesirable. The most robust solution for
single ended inputs is to place a comparator with hysteresis
in front of the CLC018. Such a part is the MC10E1652. See
Figure 6 for an example of how to hook this up.
DS100088-17
FIGURE 8. Generating ECL Outputs
DS100088-14
FIGURE 5. Single Ended Input to CLC018
DS100088-18
FIGURE 9. Connecting the CLC018 to the CLC016
POWER SUPPLIES, GROUNDING AND BYPASSING
The CLC018 uses separate power supplies for control and
data circuitry. Data circuitry is supplied via VCC and control
circuitry via VLL. Supply connection VEE, the negative-most
supply, is the common return for both. Connection details for
the different powering modes is shown in Table 1.
Internal and external capacitances, normal and parasitic,
must be charged and discharged with changes in output voltage. Charging current depends upon the size of these capacitances and the rate of change of voltage. At the fast transition times of the CLC016, small amounts of stray
capacitance at outputs can produce large output and supply
transient currents. Controlling transient currents requires
particular attention to minimizing stray capacitances and to
providing effective bypassing in the design. Good and effective bypassing consisting of 0.01 µF to 0.1 µF monolithic ceramic and 4.7 µF to 10 µF, 35V tantalum capacitors. These
capacitors should be placed as close to power pins as practical and tightly connected to the power plane sandwich using multiple vias. Needless to say, multilayer board technology should be employed for the CLC018 and similar highfrequency-capability devices.
DS100088-15
FIGURE 6. Single Ended Input to CLC018
OUTPUT INTERFACING
The outputs of the CLC018 are differential, current source
outputs. They can be converted to ECL compatible levels
with the use of resistive loads as shown in Figure 7. The output swings will have a similar temperature coefficient to
10KECL if a 1N4148 diode is used to set VOH. For most commercial temperature range applications, a 75Ω resistor can
be used as shown in Figure 8. Many circuits with differential
inputs, such as the CLC016 Data Retimer With Automatic
Rate Selection, do not require true ECL levels, so the load
resistors can be connected directly to the positive rail as
shown in Figure 9.
CONFIGURING THE SWITCH
The CLC018 can be configured so that any output may be independently connected to any input and any input be connected to any or all outputs. Each output may be independently enabled or placed in a high-impedance state.
Data controlling the switch matrix and output mode are
stored in two ranks of eight, 4-bit registers, one register per
output. The three most-significant bits in each register identify the input to be connected to that output. The leastsignificant bit controls whether the output is active or
TRI-STATE. A particular register in the first rank, the LOAD
REGISTERS, is selected by a 3-bit word placed on the out-
DS100088-16
FIGURE 7. Generating 10k ECL Outputs
www.national.com
8
Operation
The entire crosspoint matrix may now be configured with the
data held in the load registers. To implement the configuration, apply a high-going pulse to the CNFG input pin. The
contents of the load registers are transferred to the configuration registers and the new configuration of all crosspoints
is effected.
The CLC018 Configuration Truth Table is shown at the end
of the datasheet.
(Continued)
put address (OA) bus. Data to be written into the load register, consisting of the 3-bit address of the input to be connected to that output and the output-enable control bit, are
placed on the input address (IA) bus. Input data is stored in
the load registers at the low-to-high transition of the LOAD
input pin with chip-select (CS) high-true. The contents of the
load registers are transferred to the second rank of CONFIGURATION REGISTERS at the low-to-high transition of
the CNFG input signal (with CS high). This causes the state
of the entire switch matrix to be set to the selected configuration.
EXPANDING THE SWITCH SIZE
The CLC018 was designed for easy expansion to larger array sizes without paying a significant penalty in either speed
or power. The power dissipation of the expanded array will
be dominated by the number of active outputs, therefore
power will increase linearly with the array size even though
the number of components required increases as the square
of the array size. As an example, a single CLC018 can be
used for an 8x8 array, and it will dissipate about 0.85W. A 32
x 32 array will require 16 CLC018s and will consume only
about 4W.
The entire crosspoint may be placed in an initializing state,
with all outputs connected to input-0 and with all outputs either enabled or TRI-STATE. To do so, hold TRI low to make
outputs active, or high to place outputs in TRI-STATE, and
apply a high-going pulse to the RES input pin (with CS high).
In summary, outputs are configured by:
a) first placing the 3-bit address of that output on the OA
bus together with
b) the 3-bit address of the input to be connected to that
output on the IA bus,
c) the output-enable (TRI-STATE) control bit for that output
on the IA bus,
d) making chip-select (CS) true, and then
e) providing a high-going pulse to the LOAD input pin.
f) Repeat these four steps for each output to be configured.
9
www.national.com
Operation
(Continued)
TABLE 1. Interfacing of the Power Supplies and Bypass Capacitors
Supply Operation
I/O Data Level
Control Signal Low/High
Dual ± 5V
Single −5V
Single +5V
ECL
PECL
ECL
−5V/GND
GND/+5V
GND/+5V
1. Bypass each VEE supply
with a 0.01 µF capacitor.
2. Connect VCC and VLL to
the ground plane.
3. A power plane isn’t required for VEE but can
be used.
1. Bypass each VCC supply
with a 0.01 µF capacitor.
2. Bypass the VLL supply with
a 0.01 µF.
3. Connect VEE to the ground
plane.
4. Use a +5V power plane for
VCC.
1. Bypass each VEE supply
with a 0.01 µF capacitor.
2. Bypass the VLL supply
with a 0.01 µF.
3. Connect VCC to the
ground plane.
4. A power plane isn’t required for +5V (VLL) or
−5V (VEE) supplies. but
can be used.
Connection
Key Information
impedance transmission line as shown in Figure 10. To control the switch array, the IA, OA and TRI busses are all connected in parallel and a decoder is used to assert high the
CS of the CLC018 that is to be addressed. This is also
shown in Figure 10.
EXPANDING THE NUMBER OF OUTPUT PORTS
To expand the number of output ports in a switch array, the
inputs of multiple CLC018s are connected in parallel. The
bus used to connect the input ports should be a controlled
www.national.com
10
Operation
(Continued)
DS100088-20
FIGURE 10. 8 x 16 Crosspoint Example
EXPANDING BOTH INPUTS AND OUTPUTS
To increase both the number of inputs and outputs in an array, apply both the input port and output port expansion techniques simultaneously. In Figure 12, this is shown for the
case of a 24 input by 32 output switch array. Note that both
input and output busses need to be controlled impedance
transmission lines. The CS pins for rows of CLC018s are
connected together and become the row select inputs,
whereas the TRI pins are connected together for the columns of CLC018s and become the column select pins.
EXPANDING THE NUMBER OF INPUT PORTS
Expanding the number of inputs in a switch array is accomplished by wire-ORing the outputs together, and TRISTATEing the outputs of the CLC018s that do not have their
inputs selected. The output bus should be a controlled impedance transmission line with proper termination. This is
shown in Figure 11. The circuit uses a 1-of-2 decoder with
complemented outputs to control the TRI pins of the
CLC018s in the array. Thus, all CLC018s are programmed
simultaneously, and all of them, except for the one with the
selected input, are placed in the TRI-STATE mode.
11
www.national.com
Operation
(Continued)
DS100088-21
FIGURE 11. Expanded Input Ports
www.national.com
12
Operation
(Continued)
DS100088-22
FIGURE 12. 24 x 32 Output Switch Array
13
www.national.com
Operation
tance) are used to drive bus networks, a series resistor connects the output of the amplifier to the transmission line. This
resistor serves both as a termination for any signals travelling toward the source- end of the line and as the series leg
of a voltage divider (with the transmission line as the shunt
leg) to reduce the transmitted signal level. This resistor’s correct value is ZO − ROUT. However, a value equal to ZO may
be used successfully in most situations. The receiving end of
the line is terminated in a resistance equal to the value of ZO
of the receiving end of the line. A resistance equal to the
line’s ZO works in most situations. In cases where the bus is
heavily loaded, the receiving end termination’s value may
need to be reduced to the loaded- ZO of the line. (Please see
the material on distributed loading effects on line characteristics in the Fairchild F100K ECL 300 Series Databook and
Design Guide).
(Continued)
CALCULATING THE POWER DISSIPATION IN AN
EXPANDED ARRAY
The CLC016 dissipates about 100 mW per active output plus
about 50 mW quiescent power. With all outputs active, this is
about 850 mW. In an expanded array, all devices will dissipate quiescent power, but only those devices with active outputs will dissipate the 100 mW/output. So, an N-by-M device
array (an 8xN-input-by-8xM-output switch) with all outputs
active will dissipate N x M x 50 mW + 8 x M x 100 mW. A 32input x 32-output (4 x 4 device) switch array dissipates 4 x 4
x 50 mW + 8 x 4 x 100 mW = 4W.
CONTROLLED IMPEDANCE TRANSMISSION LINES
AND OTHER LAYOUT TECHNIQUES
Current-mode drivers, with their high equivalent generator
resistance, when used as bus drivers require a resistance
equal to ZO at each end of the bus to either power or ground
as appropriate for the design.
A detailed discussion of digital transmission line design techniques is beyond the scope of this data sheet, but many
good references are available from National Semiconductor
and others. Extensive material is available in the National Interface Databook, the Fairchild F100K ECL 300 Series Databook and Design Guide and the Motorola MECL System
Design Handbook.
All transmission lines whose length is greater than 1⁄4 wavelength of the highest frequencies present in the transmitted
signal require proper attention to impedance control to avoid
distortion of the signal. Digital signals are especially susceptible to distortion due to poorly controlled line characteristics
and reflections. With its 250 ps output transitions, which imply a bandwidth of 4 GHz or more, transmission lines driven
by the CLC018 must be carefully designed and correctly terminated. Either microstrip line, which resides on the outer
surfaces of a printed circuit board and paired with an image
ground plane, or stripline, which is sandwiched in an inner
layer between image ground planes, may be used in
CLC018 designs. With either line type, it is important to
maintain a uniform characteristic impedance over the entire
extent of the transmission line system. Likewise, the receiving end of these lines must be terminated in a resistance
equal to the characteristic impedance to preserve signal fidelity. Figure 13 shows representative methods of interfacing
to and from the CLC018.
Often, when voltage-mode drivers, such as ECL, with low
output impedance (also called equivalent generator resis-
www.national.com
Especially useful is the National Semiconductor Transmission Line RAPIDESIGNER r Sliderule and user manual AN905. The RAPIDESIGNER is available by calling the National Semiconductor Customer Response Center in your
area and asking for either Literature Number 633200-001
(ISO Metric units) or 633201-001 (English units). The User
Manual for both versions is Literature Number 100905-002
and is available on our WEB Site at http://www.national.com
as AN-905.
14
Operation
(Continued)
DS100088-23
FIGURE 13. Input/Output Bussing
15
www.national.com
Operation
(Continued)
Configuration Truth Table
IA2
IA1
IA0
OA2
OA1
OA0
TRI
RES
LOAD
CNFG
CS
X
X
X
X
X
X
X
X
X
X
0
Condition of Device
NO CHANGE
X
X
X
X
X
X
0
I
X
X
1
Load I/P 0 to All O/Ps
X
X
X
X
X
X
1
I
X
X
1
TRI-STATE All O/P 0
X
X
X
0
0
0
1
0
I
0
1
TRI-STATE O/P 0
X
X
X
0
0
1
1
0
I
0
1
TRI-STATE O/P 1
X
X
X
0
1
0
1
0
I
0
1
TRI-STATE O/P 2
X
X
X
C
B
A
1
0
I
0
1
TRI-STATE O/P CBA
•
•
•
•
•
•
•
•
•
•
•
•
R
Q
P
C
B
A
0
0
I
0
1
Load I/P PQR to O/P
CBA and Enable O/P
CBA
•
•
•
•
•
•
•
•
•
•
•
•
0
0
0
0
0
0
0
0
I
0
1
Load I/P 0 to O/P 0
0
0
0
0
0
1
0
0
I
0
1
Load I/P 0 to O/P 1
0
0
0
0
1
0
0
0
I
0
1
Load I/P 0 to O/P 2
0
0
0
0
1
1
0
0
I
0
1
Load I/P 0 to O/P 3
0
0
0
1
0
0
0
0
I
0
1
Load I/P 0 to O/P 4
0
0
0
1
0
1
0
0
I
0
1
Load I/P 0 to O/P 5
0
0
0
1
1
0
0
0
I
0
1
Load I/P 0 to O/P 6
0
0
0
1
1
1
0
0
I
0
1
Load I/P 0 to O/P 7
0
0
1
0
0
0
0
0
I
0
1
Load I/P 1 to O/P 0
0
0
1
0
0
1
0
0
I
0
1
Load I/P 1 to O/P 1
0
0
1
0
1
0
0
0
I
0
1
Load I/P 1 to O/P 2
0
0
1
0
1
1
0
0
I
0
1
Load I/P 1 to O/P 3
•
0
•
0
•
1
•
1
•
1
•
1
•
0
•
0
•
•
0
•
1
Load I/P 1 to O/P 7
I
•
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
0
0
0
I
0
1
Load I/P 7 to O/P 6
1
1
1
1
1
1
0
0
I
0
1
Load I/P 7 to O/P 7
X
X
X
X
X
X
X
0
0
I
1
Activate New
Configuration
www.national.com
16
17
CLC018 8 x 8 Digital Crosspoint Switch, 1.4 Gbps
Physical Dimensions
inches (millimeters) unless otherwise noted
64-Lead PQFP
Order Number CLC018AJVJQ
NS Package Number VJE64A
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein:
2. A critical component in any component of a life support
1. Life support devices or systems are devices or sysdevice or system whose failure to perform can be reatems which, (a) are intended for surgical implant into
sonably expected to cause the failure of the life support
the body, or (b) support or sustain life, and whose faildevice or system, or to affect its safety or effectiveness.
ure to perform when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
National Semiconductor
Corporation
Americas
Tel: 1-800-272-9959
Fax: 1-800-737-7018
Email: [email protected]
www.national.com
National Semiconductor
Europe
Fax: +49 (0) 1 80-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 1 80-530 85 85
English Tel: +49 (0) 1 80-532 78 32
Français Tel: +49 (0) 1 80-532 93 58
Italiano Tel: +49 (0) 1 80-534 16 80
National Semiconductor
Asia Pacific Customer
Response Group
Tel: 65-2544466
Fax: 65-2504466
Email: [email protected]
National Semiconductor
Japan Ltd.
Tel: 81-3-5620-6175
Fax: 81-3-5620-6179
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.