EBMPAPST 4414M

Kompaktlüfter__2011__EN__Final__17_01_2011_:Vorlage
14:26
Seite 48
DC axial fans
285 m3/h
max.
18.01.2011
Series 4400
119 x 119 x 38 mm
Highlights:
– Innovative impeller with winglets for low noise.
– Control inputs, alarm and speed signals available on request.
– High-speed version with 5000 rpm, standard models available with /2 and PWM.
L10∆ (40 °C) see P. 15
Service life L10 (Tmax)
ebm-papst standard
Temperature range
Service life L10 (40 °C)
ebm-papst standard
Nominal speed
Sintec sleeve bearings
Ball bearings
RPM
°C
Hours
Hours
2 700
-20...+70
67 500 / 35 000
140 000
1
4,2
3 300
-20...+70
65 000 / 32 500
130 000
2
5,5
3 650
-20...+70
62 500 / 30 000
120 000
3
/2
6,0
8,9
4 300
-20...+70
57 500 / 27 500
110 000
4
/2
6,4
13,0
5 000
-20...+70
50 000 / 25 000
100 000
5
/2
VDC
VDC
4412 L
150
88,3
12
7...14
37
5,0
2,5
4412 M
184
108,3
12
7...14
42
5,3
4412 N
205
120,7
12
7...14
46
5,6
4412 H
240
141,3
12
7...14
50
4412 /2 HHP
285
167,7
12
7...14,5
55
4414 L
150
88,3
24
18...28
37
5,0
2,5
2 700
-20...+70
67 500 / 35 000
140 000
1
4414 M
184
108,3
24
18...28
42
5,3
4,0
3 300
-20...+70
65 000 / 32 500
130 000
2
4414 N
205
120,7
24
18...28
46
5,6
5,2
3 650
-20...+70
62 500 / 30 000
120 000
3
4414 H
240
141,3
24
18...28
50
6,0
8,6
4 300
-20...+70
57 500 / 27 500
110 000
4
4414 HH
285
164,8
24
16...28
55
6,4
14,0
5 000
-20...+70
50 000 / 25 000
100 000
5
4414 /2 HHP
285
167,7
24
18...28
55
6,4
12,0
5 000
-20...+70
50 000 / 25 000
100 000
5
4418 L
150
88,3
48
36...60
37
5,0
2,5
2 700
-20...+70
67 500 / 35 000
140 000
1
4418 M
184
108,3
48
36...60
42
5,3
4,2
3 300
-20...+70
65 000 / 32 500
130 000
2
4418 N
205
120,7
48
36...60
46
5,6
5,2
3 650
-20...+70
62 500 / 30 000
120 000
3
4418 H
240
141,3
48
36...60
50
6,0
8,6
4 300
-20...+70
57 500 / 27 500
110 000
4
/2
4418 /2 HHP
285
167,7
48
36...60
55
6,4
13,5
5 000
-20...+70
50 000 / 25 000
100 000
5
/2
A
HP
Pa
0,6
0 ,5
0,4
0,3
100
[in H2O]
25
0,4
0,2
75
50
0,1
Pa
125
100
3
0
20
40
0,3
2
50
0,2
1
25
0,1
50
75
0
25
50
48
Watts
5
150
4
/
[in H2O]
175
125
dB(A) Bel(A)
50
75
100
100
150
NG
60
100
80
150
100
120
200
140
250
CFM
m³/h
125 CFM
200
m³/h
T
I
PWM
Specials
Voltage range
CFM
Curve
Nominal voltage
m3/h
Life expectancy
Air flow
Type
Nominal data
Power input
Air flow
Sound power level
Sound pressure level
General characteristics:
– Material: fibreglass-reinforced plastic. Impeller PA, housing PBT.
– Fully integrated electronic commutation.
– Protected against reverse polarity and locking.
– Connection via single strands AWG 24, TR 64. Bared and tin-plated.
– Air exhaust over struts. Direction of rotation clockwise, seen on rotor.
– Mass: 270 g.
P. 110
/2