FUJI EDSX5-74

FCX – AX SERIES SMALL FLANGE REMOTE SEAL TYPE
PRESSURE TRANSMITTER
FHW, FKW...3
DATA SHEET
The FCX –AX Series small flange remote seal type pressure transmitter accurately measures gauge pressure and
transmits a proportional 4 to 20mA signal.
The transmitter utilizes a unique micromachined capacitance silicon sensor with state-of -the-art microprocessor
technology to provide exceptional performance and functionality.
Totally welded construction of the seals assures excellent
reliability in high temperature and highly corrosive process
conditions.
FEATURES
1. Directly connectable to 1-1/2in and 2in flanges
The transmitter is connectable to 1-1/2in and 2in pipes
without a reducer.
2. Connectable to 1/2in and 3/4in pipes
Use of direct mounting adapter allows the transmitter to
be connected to the following process.
1/2in and 3/4in flanges
Screw connection 1/2-14NPT, 3/4-14NPT, Rc1/2, Rc3/4
3. Minimum environmental influence
The "Floating Cell" design which protects the pressure
sensor against changes in temperature, and overpressure
substantially reduces total measurement error in actual
field applications.
4. Replaceable Communication Module
Fuji micro-electronics manufacturing technology offers
replaceable communication module that makes FCX–AX
transmitter very unique in design. In case of change in
communication protocl, all that needs to be done is just to
replace the module and the transmitter gets upgraded to
the new version.
5. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both Fuji
proprietary protocol and HART. Any HART compatible
devices can communicate with FCX–AX series transmitters.
6. Application flexibility
Various options that render the FCX–AX suitable for
almost any process applications include:
— Analog indicator at either the electronics side or terminal side
— Full range of hazardous area approvals
— Built-in RFI filter and lightning arrester
— 41/2 -digits LCD meter
— Stainless steel electronics housing
— Wide selection of materials
— High temperature, vacuum seals
7. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW hand
Held Communicator (HHC) to comply with NAMUR NE43.
(Available for amplifier unit from version 24 and FXW(HHC) version
5.3.)
8. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
SPECIFICATIONS
Functional specifications
Type:
Model FHW:
Model FKW:
Service:
Span, range, and
4 to 20mA
4 to 20mA with digital signal
Liquid, gas, or vapour
overrange limit:
Span limit [kPa]{bar}
Type
Min.
FHW
F
W
F
W
3 300
{3}
4 1000
{10}
Max.
FKW
50
{0.5}
250
{2.5}
Overrange
limit
[MPa] {bar}
Range limit
[kPa]{bar}
FHW/FKW
3000
{30}
10000
{100}
–100
{–1
–100
{–1
to
to
to
to
+3000
+30}
10000
100}
4.5
{45}
15
{150}
— Lower range limit (vacuum limit) ;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: Atmospheric pressure
— Conversion factors to different units;
1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi
1kPa=10mbar=101.9716mmH2O=4.01463inH2O
Output signal:
Model FHW: 4 to 20mA DC 2-wire
Model FKW: 4 to 20mA DC with digital signal superimposed on the 4 to 20mA signal.
Power supply:
Transmitter operates on 10.5V to 45V DC
at transmitter terminals.
10.5V to 32V DC for the units with optional arrester.
EDSX5-74
Date
Apr. 10, 1999
FHW, FKW...3
Load limitations: see figure below
“Output Underscale”:
Approx. 3.8mA
(Adjustable within the range 3.2mA to
3.8mA from HHC)
[Ω]
Load resistance
2000
1533Ω
3.2
20 20.8
Over scale
Burnout
0
Normal operating range
Under scale
Probable under range
Burnout
1000
600Ω
Operating
area
500
24V
250
10
45V
16.1
10.5V
Power voltage
50
[V]
Note: For communication with HHC (Model: FXW), min. of 250Ω is required.
Hazardous locations: (Approval pending)
Authorities
BASEEFA
Factory
Mutual
RIIS
Flameproof
Ex ds IIC T5, T6
Class I II III
Div. 1
Groups B thru. G
Ex ds IIB+H2 T4
Intrinsic safety
EEx ia IIC T4, T5
Class I II III
Div. 1
Groups A thru. F
—
Type N
Nonincendive
Ex N II T5
Class I II III
Div. 2
Groups A thru. G
—
Zero/span adjustment:
Model FHW: Zero is adjustable from the external adjustment screw.
The adjustment screw can also function to
adjust span when MODE SWITCH (located on the electronics unit) is in the span
mode. INHIBIT mode to disable the adjustment screw is also available.
Model FKW: Zero and span are adjustable from the
HHC. Zero is also adjustable externally
from the adjustment screw.
Damping:
Adjustable electrical damping.
Model FHW: The time constant is adjustable to 0, 0.3,
1.2, 4.8, or 19.2 seconds.
Model FKW: The time constant is adjustable between 0
to 38.4 seconds.
Zero elevation/suppression:
Zero can be elevated or suppressed within
the specified range limit of each sensor
model.
Normal/reverse action:
Selectable by moving a jumper pin located
on the electronics unit.
Indication:
Analog indicator or 4 1/2 -digit LCD meter,
as specified.
Burnout direction: If self-diagnostic detect transmitter failure, the analog signal will be driven to either “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
Model FHW: Unless otherwise specified in the order,
the transmitter will be shipped in “Output
Hold” mode.
(Output signal just before failure happens
is maintained.)
Model FKW: Selectable from HHC
“Output Hold”:
Output signal is hold as the value just before failure happens.
“Output Overscale”:
Approx. 21.6mA
(Adjustable within the range 20.8mA to
21.6mA from HHC)
2
3.8 4
1500
21.6
Probable over range
Loop-check output:
Model FHW: Transmitter can output constant signal of
4mA, 12mA, or 20mA if MODE SWITCH
is set to the loop check mode.
Model FKW: Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA by
HHC.
Temperature limit:
Ambient: – 15 to +65°C
(– 15 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil fill transmitter)
(–10 to +60°C for silicone oil "H", "S")
For explosionproof units (flameproof or intrinsic safety),
ambient temperature must be within the limits specified by each standard.
Process:
Fill fluid
13th digit of
"Code symbols"
Process
temperature
Fluorinated oil
W, A and D
–20 to 120°C
Silicone oil
H
Y and G
0 to 250°C
– 40 to 120°C
S
0 to 250°C
Lower limit
of
static press.
Atmospheric
pressure
2.7kPa abs
{20mmHg
abs}
Storage: – 40 to +70°C
Humidity limit:
0 to 100% RH
Communication: (Model FKW only)
With HHC (Model FXW, consult Data
Sheet No. EDS8-47), following information can be remotely displayed or reconfigured.
Items
Display
Set
Tag No.
v
Model No.
v
v
v
Serial No.
v
—
Engineering unit
v
v
Range limit
v
—
Measuring range
v
v
Damping
v
v
Output mode
v
v
Burnout direction
v
v
Adjustment
v
v
Output adjust
—
v
Data
v
—
Self diagnoses
v
—
Printer
—
—
External switch lock
v
v
Transmitter display(*)
v
v
Note: (*) HHC's version must be more than 5.0 (or
FXW
1– 2), to use this function.
Performance specifications
Physical specifications
Accuracy rating: (including linearity, hysteresis, and re(Standard)
peatability)
For spans greater than 1/10 of URL: ± 0.25% of span
For spans below 1/10 of URL (Model FKW only):
± 0.17+0.08 0.1 x URL % of span
Span
(Option)
For spans greater than 1/10 of URL: ± 0.1% of span
For spans below 1/10 of URL (Model FKW only):
± 0.05+0.05 0.1 x URL % of span
Span
Linearity:
0.1% of calibrated span
Stability:
± 0.2% of upper range limit (URL) for 24
months
Temperature effect:
Effect per 28°C change between the limits of – 15°C and +65°C
Zero shift: ± 0.5%/28°C
(x equal to 1/6.5 URL or more)
URL
Zero shift; ± (0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Total shift; ± 0.75%/28°C
(x less than 1/6.5 URL or more)
URL
Total shift; ± (0.25 + 0.5
)%/28°C
6.5 x x
(x less than 1/6.5 URL)
Where, x:
Calibrated span
(
)
(
)
URL:
Maximum span (Upper Range
Limit)
Note 1: Condition:
Capillary length: 3m max.
In case the capillary length is 5m, the performance becomes 1.5 times worse than
above.
Note 2: In case the 7th code (material code) is
other than W, A, B, C or D, the performance becomes 2.5 times worse than
above.
Note 3: Above specifications are based on the conditions that flange and sensor unit are at
the same temperature and in the same
level. If temperature is different at flange,
capillary or sensor unit, output variation
may increase.
Overrange effect: Zero shift; 0.2% of URL/(1.5 x URL)
Supply voltage effect:
Less than 0.05% of calibrated span per
10V
RFI effect:
Less than 0.2% of URL for the frequencies of 20 to 1000MHz and field strength
30 V/m when electronics covers on.
Step response: Time constant: 0.3s (with 1.5m capillary)
Dead time: approximately 0.3s
(without electrical damping)
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit
and earth.
Insulation resistance:
More than 100MΩ/500V DC.
Turn-on time:
4 sec.
Internal resistance for external field indicator:
12Ω or less
Electrical connections:
G1/2, 1/2-14 NPT, Pg13.5, or M20 x 1.5
conduit, as specified.
Process connections:
JIS;
10K, 20K, 30K, 63K –40, 50A
10K, 20K, 30K, 63K –15, 20A (with
Adapter)
ANSI/JPI;
150LB, 300LB, 600LB, –1 1/2 ", 2"
150LB, 300LB, 600LB, –1/2", 3/4" (with
Adapter)
Screw connection (with Adapter) ;
Rc1/2, Rc3/4, 1/2-14NPT, 3/4-14NPT
Diaphragm extension:
0, 50, 100, 150, or 200mm as specified.
(See model code. Extended diaphragm is
available only with 316L stainless steel diaphragm)
Process-wetted parts material:
Diaphragm: 316L stainless steel, Hastelloy-C
Monel or Tantalum
Flange face: 316 stainless steel, Hastelloy-C
lining
Monel lining or Tantalum lining
Extension: 316 stainless steel
(Refer to "Code symbols")
Non-wetted parts material:
Electronics housing: Low copper die-cast
aluminum alloy (standard), finished
with polyester coating, or 316 stainless
steel (SCSI4 per JIS G5121), as specified.
Capillary: In case of 13th code "Y. W. G. A.
D", PVC armored stainless steel.
In case of 13th code "H. S",
stainless steel armored stainless steel.
Mounting flange: (option) 304 stainless
steel or carbon steel
Fill fluid: Silicone oil (standard) or fluorinated oil (Daifloil)
Mounting bracket: Carbon steel with epoxy coating or 304 stainless steel, as
specified
Environmental protection:
IEC IP67 and NEMA 4X
Mounting:
On 60.5mm (JIS 50A) pipe using mounting bracket, direct wall mounting
Mass {weight}:
Transmitter approximately 10kg without
options.
Add; 0.5kg for mounting bracket
0.8kg for indicator option
4.5kg for stainless steel housing
option
1.5kg per 50mm extension of diaphragm
3
FHW, FKW...3
ACCESSORIES
Optional features
Indicator:
A plug-in analog indicator (1.5% accuracy)
can be housed in the electronics compartment or in the terminal box of the housing.
An optional 41/2 digits LCD meter is also
available.
Arrester:
A built-in arrester protects the electronics
from lightning surges.
Lightning surge immunity is 4kV (1.2 x
50µs).
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all process wetted parts oil-free.
The fill fluid is fluorinated oil.
Chlorine service: Oil-free procedures as above. Includes
fluorinated oil for fill.
Not available with material code “W”.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for use
on oxygen or chlorine measurement.
Vacuum and high temperature service:
Special silicone oil and filling procedure
are applied.
See below figure.
Hand-held communicator:
(Model FXW, refer to Data Sheet No.
EDS8-47)
Communication module: (Standard for FKW)
By adding communication module, remote setting function becomes available
for model FHW.
Remark: When the communication module is connected, the operation mode of external
zero/span adjustment screw is limited to
zero adjustment only.
Filled liquid:
Silicone (Code Y,G)
[kPa abs]
{m bar abs}
Silicone (Code S)
Operating pressure
101
{1010}
53.3
{533}
Operating area
13.3
{133}
Non-operating
area
2.7
{27}
–40 0
60 85 120
Process temperature
200 230 250
[°C ]
Fig. 1 Relation between process temperature and
operating pressure
Customer tag:
Coating of cell:
A stainless steel tag for customer tag data
is wired to the transmitter.
Cell's surface is finished with epoxy/polyurethane double coating. Specify if environment is extremely corrosive.
The product conforms to the requirements of the
Electromagnetic compatibility Directive 89/336/EEC as
detailed within the technical construction file number
TN510412. The applicable standards used to demonstrate
compliance are :EMI (Emission)
EN50081-1 : 1992
Test item
Frequency range
Basic standard
Applicable Electromagnetic Radiation
Disturbance
30-1000MHz
EN55022
Class B
EMS (Immunity)
EN50082-1 : 1992
No.
Test item
Test
specification
Basic
standard
Performance
criteria
1
Electrostatic
discharge
8kV (Air)
IEC 801-2:1984
B
2
Radio-frequency 27-500MHz
electromagnetic 3V/m
IEC 801-3:1984
field.
(Unmodulated)
A
3
Fast transients
common mode
0.5kV, 5/50
(Tr/Th) ns
5kHz Rep.
IEC 801-4:1988
B
"LVD - The transmitter is not covered by the requirements
of the LVD standard."
4
CODE SYMBOLS
1 2 3 4 5 6 7 8
F
W
3
9 10 11 12 13
14 15 16 17 18 19 20
Description
0
Type
4 to 20mA, Output type
4 to 20mA with digital signal, Output type
FHW
FKW
Conduit connection <4th digit>
G 1/2
1/2 - 14NPT
Pg 13.5
M20 X 1.5
S
T
V
W
Flange <5th digit>
Material
Size and rating
304 stainless
JIS 10K 40A
steel
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
Carbon steel
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 1/2"
ANSI/JPI 150LB 2"
ANSI/JPI 300LB 1 1/2"
ANSI/JPI 300LB 2"
ANSI/JPI 600LB 1 1/2"
ANSI/JPI 600LB 2"
None
40A, 1 1/2B
(Wafer type)
50A, 2B
Direct mounting adapter connection (* 1)
0
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
T
U
V
W
X
Y
Span limit [kPa] {m bar} <6th digit>
FHW
FKW
300...3000 (3..30)
50...3000 ( 0.5...30)
1000..10000 (10...100) 250...10000 (2.5...100)
3
4
Material/diapharagm extension <7th digit>
Diaphragm
Flange face
W
A
B
C
D
316L stainless steel 316 stainless steel
H
M
T
Hastelloy-C
Monel
Tantalum
Hastelloy-C
Monel
Tantalum
Diaphragm extension (mm)
0
50
100
150
200
 (* )


2
0
0
0
Note 1: Direct mounting adapter type is specified at 16th to 20th digit.
Direct mounting adapter is available only for 7th digit code "W".
2: Diaphragm extension is available only for 2" (50A) flanges.
5
FHW, FKW...3
1 2 3 4 5 6 7 8
F
W
9 10 11 12 13
14 15 16 17 18 19 20
Description
3
Indicator and arrester <9th digit>
Indicator
None
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
None
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
Digital, 0 to 100%
Digital, custom scale
Digital, 0 to 100%
Digital, custom scale
A
B
D
J
E
F
H
K
L
P
Q
S
Arrester
None
None
None
None
Yes
Yes
Yes
Yes
None
None (Model FKW only)
Yes
Yes (Model FKW only)
Approvals for hazardous locations <10th digit> (Approval pending)
None (for ordinary locations)
JIS, Flameproof (Conduit seal) (Available for 4th digit code "S")
JIS, Flameproof (Cable gland seal) (Available for 4th digit code "S")
FM, Flameproof (or explosionproof) (Available for 4th digit code "T")
BASEEFA, Flameproof (Conduit seal)
BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only)
FM, Intrinsic safety and Nonincendive
CENELEC, Intrinsic safety
CENELEC, Intrinsic safety and BASEEFA, Type N
A
B
C
D
M
N
H
K
P
Capillary and mounting bracket <11th digit>
mounting bracket
Capillary
A
B
G
Carbon steel
1.5m
3m
5m
D
E
L
Stainless steel
1.5m
3m
5m
Stainless steel parts <12th digit>
Stainless steel tag plate Stainless steel elec. housing
None
None
Yes
None
None
Yes
Yes
Yes
None
None
Yes
None
None
Yes
Yes
Yes
Y
B
C
E
M
N
P
Q
Coating of cell
None
None
None
None
Yes
Yes
Yes
Yes
Treatment/Fill fluid <13th digit>
Y
W
G
A
D
H
S
Treatment
Fill fluid
None
None
Degreasing
Oxygen service
Chlorine service
High temp. 250°C
High temp. and vacuum (250°C)
Silicone oil (for general use)
Fluorinated oil
Silicone oil
Fluorinated oil (7th digit code "W", "A", "B", "C" and "D")
Fluorinated oil (7th digit code "H" and "T")
Silicone oil
(7th digit code "W", "A", "B", "C" and "D")
Silicone oil
}
Teflon membrane <14th digit>
None
Yes (7th digit code "W", "H", "M", and "T")
Y
C
Y
A
B
E
Bolt/nut <15th digit>
None
Standard (Cr-Mo alloy hexagon socket head cap bolt/
carbon steel nut)
Cr-Mo alloy hexagon bolt/carbon steel nut
304 stainless steel bolt/304 stainless steel nut
6th digit code "3"
6th digit code "4"
Odering information
1. When odering this instrument, specify the output orientation (burnout direction) in case of abnormality in the transmitter.
Unless otherwise specified, the output hold function is supplied.
6
Specifications of Direct Mounting Adapter {for 15, 20A (1/2, 3/4") connection} and others
Note 1. When odering the instrument with direct mounting adapter, specify "Y" in the 5th digit of Code Symbol, and specify
16th digit to 20th digits.
When odering the instrument without direct mounting adapter, nothing should be filled in the 16th to 20th digits.
2. Unless otherwise described in the specifications, leave the 21st digit blank.
1 2 3 4 5 6 7 8
F
W
9 10 11 12 13
14 15 16 17 18 19 20
Description
3
1
1
2
2
3
3
6
6
1
1
2
2
4
4
S
S
S
S
Process connection (direct mounting adapter) <16th to 17 digit>
JIS 10K 15A
JIS 10K 20A
JIS 20K 15A
JIS 20K 20A
JIS 30K 15A
JIS 30K 20A
JIS 63K 15A
JIS 63K 20A
ANSI/JPI 150LB 1/2"
ANSI/JPI 150LB 3/4"
ANSI/JPI 300LB 1/2"
ANSI/JPI 300LB 3/4"
ANSI/JPI 600LB 1/2"
ANSI/JPI 600LB 3/4"
Screw connection Rc1/2
Screw connection Rc3/4
Screw connection Rc1/2 - 14NPT
Screw connection Rc3/4 - 14NPT
1
2
1
2
1
2
1
2
H
T
H
T
H
T
R
2
N
T
Material (direct mounting adapter) <18th digit>
Adapter
W
Bolts/nuts
(* 1)
316 Stainless Steel Cr-Mo steel/carbon steel
Vent/drain (for direct mounting adapter) <19 th digit>
Standard
Long type
G
N
1
2
Gasket (for direct mounting adapter) <20th digit>
Standard (Teflon) (Only Y, W, G, A and D can be specified on 13th digit).
For high temperature (spiral gasket) (Only H and S can be specified on
13th digit).
*1 For connection of transmitter receiving pressure unit and direct mounting adapter
7
FHW, FKW...3
Fastener
(In case of 10th
digit code “B,C,M,N”)
Zero/span adj. screw
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
70
110
50
φ 80
104
Up
88
Down
30 38
“A”
Conduit conn.
224
Cable gland
(option)
See note
“B”
Conduit conn.
N holes
h dia.
Inner of gasket
Detail “A”
(Conduit conn.)
Detail “B”
71
17
K M
51
φ 48
φ 49
φ 84
φE
φD
φ 13
φ 15
71
Earth terminal
(both side)
See table 1
(27)
J
191
20
G1/2
t
φ 80
See table 1
252
With field ind.
(option)
7th digit of
Code symbols
W, H, M, T
S
2-M8 × 12
L
Mass approx.
[kg]
50
70
120
Conduit conn.
4th digit of
Code symbols J
M
K
17
G1/2
T
1/2-14NPT
V
Pg13.5
W
M20x1.5
16
8
16
8
Earth terminal
No. 8-32UNC
5
M4
4.5
M4
5
M4
L
11th digit of Capillary
code symbols length S [mm]
0
9.5
A,D
1500
A
50
10.5
B, E
3000
B
100
11.5
G, L
5000
C
150
12
D
200
12.5
5th digit of code symbols φ D φ E
S
4 holes
9 dia.
58
t
N-φ h
Flange
0, G
140 105
36
4-19
JIS-10K-40A
1, H
155 120
36
4-19
JIS-10K-50A
2, J
140 105
38
4-19
JIS-20K-40A
3, K
155 120
38
8-19
JIS-20K-50A
4, L
160 120
42
4-23
JIS-30K-40A
5, M
165 130
42
8-19
JIS-30K-50A
6, N
175 130
52
4-25
JIS-63K-40A
7, P
185 145
54
8.23
JIS-63K-50A
A, Q
127 98.4
B, R
152 120.6 39.5 4-20
C, S
156 114.3
D, T
165 127
E, U
156 114.3 42.5 4-23
F, V
165 127
37.5 4-16
41
ANSI/JPI-150LB-1 1/2"
ANSI/JPI-150LB-2"
4-23
ANSI/JPI-300LB-1 1/2"
42.5 8-20
ANSI/JPI-300LB-2"
ANSI/JPI-600LB-1 1/2"
45.5 8-20
ANSI/JPI-600LB-2"
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Table 1
CONNECTION DIAGRAM
2-M6 screw depth 9
<Optional stainless steel tag>
+
–
CK + CK –
+ –
71
φ 84
φ 49
75
Inner of gasket
20
20
<Wafer type>
8
Note: In case of wafer type, flange is excluded
from the scope of supply.
Mount flange, referring to the view.
S
H
F KWT
V
W
0
1
2
3
4
5
6
3
OUTLINE DIAGRAM (Unit:mm)
Zero/span adj. screw
Fastener
(In case of 10th
digit code “B,C,M,N”)
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
70
110
50
φ 80
104
Up
88
Down
30 38
“A”
Conduit conn.
224
Cable gland
(option)
See note
58
4 holes
9 dia.
“B”
Conduit conn.
Specifications for instrument with
direct mounting adapter
80
N holes H dia.
20
t
Detail “A”
(Conduit conn.)
Detail “B”
S
φ 84
φF
φE
17
K M
φD
φ 13
φ 15
G1/2
(T) In case of
ANSI/JPI-600LB flange
With field ind.
(option)
Earth terminal
(both side)
See table 1
51
71
25
(6.4) In case of
ANSI/JPI-600LB flange
See table 1
(102)
J
Vent/drain plug
(27)
191
φ 80
Long vent/drain plug
(added specification)
Table 1
Conduit conn.
4th digit of
K
252
Code symbols J
S
2-M8 × 12
T
1/2-14NPT
V
Pg13.5
W
M20x1.5
16th digit of
CONNECTION DIAGRAM
–
CK + CK –
+ –
S
H
F KWT Y
V
W
3
17th digit of
code symbols code symbols
50
70
120
+
G1/2
1
2
3
4
6
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
17
16
8
16
M
Earth terminal
11th digit of
code symbols
M4
8
No. 8-32UNC
5
4.5
M4
5
M4
øD
øE
øF
t
N-øh
S
A,D
1500
B, E
3000
G, L
5000
Flange
1
1
95
70
51
12
4-15
1
2
100
75
56
14
4-15
JIS-10K-20A
2
1
95
70
51
14
4-15
JIS-20K-15A
2
2
100
75
56
16
4-15
JIS-20K-20A
3
1
115
80
55
18
4-19
JIS-30K-15A
3
2
120
85
60
18
4-19
JIS-30K-20A
6
1
120
85
55
23
4-19
JIS-63K-15A
6
2
135
95
60
25
4-23
JIS-63K-20A
1
H
89
60.3
34.9 11.5 4-16
ANSI/JPI-150LB-1/2"
1
T
98
69.9
42.9 13
ANSI/JPI-150LB-3/4"
2
H
95
66.7
34.9 14.5 4-16
ANSI/JPI-300LB-1/2"
2
T
117
82.5
42.9 16
ANSI/JPI-300LB-3/4"
4
H
95
66.7
34.9 14.5 4-16
ANSI/JPI-600LB-1/2"
4
T
117
82.5
42.9 16
ANSI/JPI-600LB-3/4"
4-16
4-20
4-20
JIS-10K-15A
9
FHW, FKW...3
OUTLINE DIAGRAM (Unit:mm)
Fastener
(In case of 10th
digit code “B,C,M,N”)
Zero/span adj. screw
In case of 4th
digit code “S,V,W,X”
MTG. pipe
JIS 50A (2")
U - bolt M8
70
110
50
φ 80
104
UP
88
DOWN
30 38
“A”
Conduit conn.
Detail “A”
(Contuit conn.)
224
Cable gland
(option)
See note
Detail “B”
φ 13
“B”
Conduit
conn.
17
K M
φ 15
4 holes
9 dia.
58
J
23
G1/2
20
See table 1
Earth terminal
(both side)
See table 1
S
With field ind.
(option)
51
71
Press. conn. "D"
(27)
φ 80
φ 84
191
252
25
(102)
Long vent/drain plug
Long vent/drain plug
(option)
Specifications for instrument
with direct mounting adapter
(screw connection type)
2-M8 × 12
Table 1
4th digit of
Conduit conn.
J
Code symbols
50
70
120
S
G1/2
K
M
17
8
T
1/2-14NPT 16
V
Pg13.5
W
M20x1.5
8
16
5
Earth terminal
11th digit of
code symbols
M4
No. 8-32UNC
4.5
M4
5
M4
S
A,D
1500
B, E
3000
G, L
5000
CONNECTION DIAGRAM
16th digit of code symbols 17th digit of code symbols
Press. conn. "D"
S
R
Rc 1/2
S
N
1/2 - 14NPT
S
2
Rc 3/4
+
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan
Phone: 81-3-5435-7111
http://www. fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm
CK + CK –
+ –
S
H T Y
F KW
V
W
3/4 - 14NPT
S
T
Note *: Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Head office
–
3
S
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo 191-8502 Japan
Phone: 81-42-585-6201, 6202
Fax: 81-42-585-6187, 6189
Information in this catalog is subject to change without notice.