MERITEK SAC7.0

SAC
Transient 9ROWDJH6XSSUHVVRUV
Series
MERITEK
FEATURES
Plastic package has Underwriters Laboratory Flammability Classification 94V-O.
Glass passivated junction.
500W peak pulse power capability with a 10/1000µs waveform,
repetition rate (duty cycle): 0.01%.
Excellent clamping capability.
Low incremental surge resistance.
Fast response time: typically less than 5.0ns from 0 volt to VBR min.
Ideal for data line applications.
DOA
DO-204AC/DO-15
High temperature soldering guaranteed: 265℃/10 seconds/.375”,
(9.5mm) lead length, 5lbs., (2.3kg) tension.
MECHANICAL DATA
M
Case: JEDEC DO-15 molded plastic over a passivated junction.
Terminals: Solder plated axial leads, solderable per MIL-STD-750, Method 2026.
Polarity: Color band denotes cathode.
Mounting Position: Any.
Weight: 0.015 ounce, 0.4 grams.
MM
AXIMUM RATINGS AND CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified.
RATING
SYMBOL
VALUE
UNIT
Peak Pulse Power Dissipation on 10/1000μs waveform. (Note 1,Fig. 1)
PPPM
Minimum 500
Watts
Peak Pulse Current on 10/1000μs waveform. (Note 1,Fig. 3)
IPPM
See Table
Amps
Steady State Power Dissipation at TL =75℃,Lead length .375” (9.5mm).
PM(AV)
3.0
Watts
TJ , TSTG
-55 to +175
( Fig. 5)
Operating junction and Storage Temperature Range.
℃
Note: Non-repetitive current pulse, per Fig. 3 and derated above TA = 25℃ per Fig. 2.
All specifications are subject to change without notice.
1
Rev 7
SAC
Transient 9ROWDJH6XSSUHVVRUV
Series
MERITEK
PACKAGE DIMENSIONS
d
s
DIA.
DIA.
L
T
L
DO-204AC/DO-15
Millimeters
Item
Inches
Min.
Max.
Min.
Max.
L
25.40
-
1.000
-
T
5.80
7.60
0.230
0.300
d
2.60
3.60
0.104
0.140
s
0.71
0.86
0.028
0.034
SPECIFICATIONS
Minimum
Reverse
Breakdown
Part Stand-Off
Voltage
Number Voltage @IT=1.0mA
Maximum
Peak
Maximum Working Inverse
Peak
Inverse Blocking Inverse
Junction
Pulse
Capacitance Blocking Leakage Blocking
Current
Voltage Current Voltage
@0V
FIG.3
Maximum Maximum
Reverse Clamping
Voltage
Leakage
@VRWM @IPP=5.0A
VRWM(V)
VBR(V)
IR(µA)
VC(V)
IPP(A)
pF
VWIB(V)
IIB(mA)
VPIB(V)
SAC5.0
5.0
7.60
300
10.0
44.0
50
75
1.0
100
SAC6.0
6.0
7.90
300
11.2
41.0
50
75
1.0
100
SAC7.0
7.0
8.33
300
12.6
38.0
50
75
1.0
100
SAC8.0
8.0
8.89
100
13.4
36.0
50
75
1.0
100
SAC8.5
8.5
9.44
50
14.0
34.0
50
75
1.0
100
SAC10
10.0
11.10
5
16.3
29.0
50
75
1.0
100
SAC12
12.0
13.30
1
19.0
25.0
50
75
1.0
100
SAC15
15.0
16.70
1
23.6
20.0
50
75
1.0
100
SAC18
18.0
20.00
1
28.8
15.0
50
75
1.0
100
SAC22
22.0
24.40
1
35.4
14.0
50
75
1.0
100
SAC26
26.0
28.90
1
42.3
11.1
50
75
1.0
100
SAC30
30.0
33.30
1
48.6
10.0
50
75
1.0
100
SAC36
36.0
40.00
1
60.0
8.6
50
75
1.0
100
SAC45
45.0
50.00
1
77.0
6.8
50
150
1.0
200
SAC50
50.0
55.50
1
88.0
5.8
50
150
1.0
200
2
Rev 7
SAC
Transient 9ROWDJH6XSSUHVVRUV
Series
MERITEK
RATING AND CHARACTERISTIC CURVES
(TA: 25°C UNLESS OTHERWISE SPECIFIED)
Figure 1 - Peak Pulse Power Rating Curve
Figure 2 - Pulse Derating Curve
100
Percentage of Rated Power (%)
PPPM-Peak Pulse Power (kW)
1000
100
10
1
0.1
0.000001
0.00001
0.0001
A verage Power
75
50
25
0
0.001
td-Pulse Width (Sec.)
Figure 3 - Pulse Waveform
Peak Power
(Single Pulse)
0
25
50
75
100
125
150
TL Lead Temperature (ºC)
175
Figure 4 - AC Line Protection Application
150
IPPM - Peak Pulse Current, % RSM
I
tr=10µsec
T J =2 5°C
Pulse Width(td) is defined
as the point where the peak
current decays to50% of IPPM
Peak Value
IPPM
10 0
Half Value
IPPM
IPPM
(
50
2
)
10/1000µsec. Waveform
as defined by R.E.A
Low Capacitance
Application Note: Device must be used with two
units in parallel, opposite in polarity as shown in
circuit for AC signal line protection.
td
0
1.0
0
2.0
3.0
4.0
t-Time (ms)
Figure 5 - Steady State Power Dissipation Derating Curve
Steady State Power dissipation (W)
3.5
3
2.5
2
1.5
1
0.5
0
0
25
50
75
100
125 150
175 200
T L -Lead Temperature (ºC)
3