ETC HFBR

Agilent HFBR-2412TC and
HFBR-2416TC Conductive Port
Option for Low Cost Miniature
Link Components
Technical Data
HFBR-2412TC
HFBR-2416TC
Features
Applications
• Significantly Decreases
Effect of Electromagnetic
Interference (EMI) on
Receiver Sensitivity
• Available with Threaded ST
Styled Port Receivers
• Allows the Designer to
Separate the Signal and
Conductive Port Grounds
Agilent recommends that the
designer use separate ground
paths for the signal ground and
the conductive port ground in
order to minimize the effects of
coupled noise on
the receiver circuitry. If the
designer notices that extreme
noise is present on the system
chassis, care should be taken to
electrically isolate the conductive
port from the chassis.
Description
The conductive port option for
the Low Cost Miniature Link
component family consists of a
grounding path from the
conductive port to four
grounding pins as shown in the
package outline drawing. Signal
ground is separate from the four
grounding pins to give the
designer more flexibility. This
option is available with all
Threaded ST panel mount styled
port receivers. Electrical/optical
performance of the receivers is
not affected by the conductive
port. Refer to the HFBR-2412TC
and HFBR-2416TC data sheets
for more information.
In the case of ESD, the conductive port option does not alleviate
the need for system recovery
procedures. A 15 kV ESD event
Package Outline
NON-CONDUCTIVE
PLASTIC HOUSING
4
CONDUCTIVE
PLASTIC PORT
5
3
6
2
7
1 8
PIN NO. 1
INDICATOR
entering through the port will not
cause catastrophic failure for any
HFBR-2412TC and HFBR2416TC receivers, but may cause
soft errors. The conductive port
option can reduce the amount of
soft errors due to ESD events, but
does not guarantee error-free
performance.
Pin
1
2
3
4
5
6
7
8
Function
Port Ground Pin
Part Dependent
Part Dependent
Port Ground Pin
Port Ground Pin
Part Dependent
Part Dependent
Port Ground Pin
Reliability Information
Ordering Information
Low Cost Miniature Link
components with the Conductive
Port Option are as reliable as
standard HFBR-2412TC and
HFBR-2416TC components. The
following tests were performed to
verify the mechanical reliability of
this option.
HFBR-2412TC-820 nm Receiver,
ST housed, 5 MBd, TTL Output,
Conductive Port.
HFBR-2416TC-820 nm Receiver,
ST housed, 125 MHz, Analog
Output, Conductive Port.
Mechanical and Environmental Tests [1]
Test
MIL-STD-883/
Other
Reference
Test Conditions
Units
Tested
Total
Failed
Temperature Cycling
1010
Condition B
-55°C to +125°C
15 min. dwell/5 min. transfer
100 cycles
70
0
Thermal Shock
1011
Condition B
-55°C to +125°C
5 min. dwell/10 sec. transfer
500 cycles
45
0
High temp. Storage
1008
Condition B
TA = 125°C
1000 hours
50
0
Mechanical Shock
2002
Condition B
1500 g/0.5 ms
5 impacts each axis
40
0
Seal Dye Penetrant
(Zyglo)
1014
Condition D
45 psi, 10 hours
No leakage into microelectronic cavity
15
0
Solderability
2003
245°C
10
0
Resistance to
Solvents
2015
3 one min. immersion brush
after solvent
13
0
Chemical Resistance
–
5 minutes in Acetone, Methanol,
Boiling Water
12
0
TemperatureHumidity
–
TA = 85°C, RH = 85%
Biased, 500 hours
30
0
Lead Integrity
2004
Condition B2
8 oz. wt. to each lead tested for
three 90° arcs of the case
16
0
IEC-801-2
Direct contact discharge to port,
0-15 kV [2]
16
0
Electrostatic
Discharge (ESD)
Notes:
1. Tests were performed on ST products with the conductive port option.
2. Agilent has previously used an air discharge method to measure ESD; results using this method vary with air temperature and humidity.
The direct contact discharge method is perferred due to better repeatability and conformance with IEC procedures. ESD immunity
measured with the air discharge method is generally higher than with the direct contact discharge method.
www.semiconductor.agilent.com
Data subject to change.
Copyright © 2001 Agilent Technologies, Inc.
June 22, 2001
Obsoletes 5980-1062E (10/00)
5988-2010EN