ETC SY10/100EPT20V

ECL Pro™
SY10EPT20V
SY100EPT20V
FINAL
5V/3.3V LVTTL/LVCMOS-toDIFFERENTIAL LVPECL
TRANSLATOR
FEATURES
■
■
■
■
■
■
■
■
3.3V and 5V power supply options
300ps typical propagation delay
Differential LVPECL output
ICC Max 20mA
PNP LVTTL input for minimal loading
Q output will default HIGH with inputs open
High bandwidth to 800MHz typical
Available in 8-pin MSOP and SOIC package
ECL Pro™
DESCRIPTION
The SY10/100EPT20V is a TTL/CMOS to differential
PECL translator. Capable of running from a 3.3 or 5V
supply, the part can be used in either LVTTL/LVCMOS/
LVPECL or TTL/CMOS/PECL systems.
The device only requires a single positive supply of
3.3V or 5V - no negative supply is required.
The tiny 8-pin MSOP package and the low skew, dual
gate design of the EPT20V makes it ideal for those
applications where space, performance, and low power
are at a premium.
PIN CONFIGURATION/BLOCK DIAGRAM
NC 1
8 VCC
LVTTL
Q 2
/Q 3
LVPECL
NC 4
PIN NAMES
7 D
6 NC
Pin
5 GND
(Available in 8-pin SOIC or 8-pin MSOP)
Function
Q, /Q
Differential LVPECL Output
D
LVTTL Input
VCC
Positive Supply
GND
Ground
ECL Pro is a trademark of Micrel, Inc.
Rev.: C
1
Amendment: /0
Issue Date: March 2003
ECL Pro™
SY10EPT20V
SY100EPT20V
Micrel
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Paramter
TRUTH TABLE
Value
Unit
D
Q
/Q
VCC
Power Supply Voltage
–0.5 to +7.0
V
H
H
L
VIN
TTL Input Voltage
–0.5 to VCC
V
L
L
H
IIN
TTL Input Current
–30 to +5.0
mA
Open
H
L
IOUT
PECL Output Current
–Continuous
–Surge
mA
50
100
Tstore
Storage Temperature
–65 to +150
°C
TA
Operating Temperature
–40 to +85
°C
Note 1.
Permanent device damage may occur if ABSOLUTE MAXIMUM
RATINGS are exceeded. This is a stress rating only and
functional operation is not implied at conditions other than those
detailed in the operational sections of this data sheet. Exposure
to ABSOLUTE MAXIMUM RATlNG conditions for extended
periods may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
VCC = +3.3V ±10% or +5.0V ±10%
TA = –40°C
Symbol
Parameter
Power Supply Current
ICC
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
—
20
—
20
—
—
20
—
20
mA
—
TTL DC ELECTRICAL CHARACTERISTICS
VCC = +3.3V ±10% or +5.0V ±10%
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
Unit
Condition
VIH
Input HIGH Voltage
2.0
—
2.0
—
2.0
—
—
2.0
—
V
—
VIL
Input LOW Voltage
—
0.8
—
0.8
—
—
0.8
—
0.8
V
—
IIH
Input HIGH Current
—
—
20
100
—
—
20
100
—
—
—
—
20
100
—
—
20
100
µA
VIN = 2.7V
VIN = VCC
IIL
Input LOW Current
—
–0.2
—
–0.2
—
—
–0.2
—
–0.2
mA
VIN = 0.5V
VIK
Input Clamp Voltage
—
–1.2
—
–1.2
—
—
–1.2
—
–1.2
V
IIN = –18mA
Unit
Condition
PECL DC ELECTRICAL CHARACTERISTICS
VCC = +3.3V ±10% or +5.0V ±10%
TA = –40°C
Symbol
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max.
VOH
Output HIGH Voltage(1)
10EPT 3920
100EPT 3915
4110
4120
3980
3975
4160
4120
4020
3975
—
—
4190
4120
4090
3975
4280
4120
VOL
Output LOW Voltage(1)
3350
3445
3050
3190
3370
3380
3050
3190
—
—
3370
3380
3050
3190
3405
3380
Note 1.
Parameter
TA = 0°C
10EPT 3050
100EPT 3170
mV
mV
These values are for VCC = 5.0V. Level Specifications will vary 1:1 with VCC.
2
ECL Pro™
SY10EPT20V
SY100EPT20V
Micrel
AC ELECTRICAL CHARACTERISTICS(1)
VCC = +3.3V ±10% or +5.0V ±10%
TA = –40°C
Symbol
Parameter
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Typ.
Max.
Min.
Max. Unit
Condition
tPLH
tPHL
Propagation Delay(1)
100
600
100
600
100
—
600
100
600
ps
50Ω to VCC – 2.0V
tskpp
Part-to-Part Skew(2)
—
500
—
500
—
—
500
—
500
ps
50Ω to VCC – 2.0V
fMAX
Maximum Input Frequency
350
—
350
—
350
—
—
350
—
MHz
50Ω to VCC – 2.0V
fMAX
Maximum Toggle Frequency
—
800
—
800
—
—
800
—
800
MHz
50Ω to VCC – 2.0V
tr
tf
Output Rise/Fall Time
(20% to 80%)
200
500
200
500
200
—
500
200
500
ps
50Ω to VCC – 2.0V
Note 1.
Input Rise Time < 1.0ns.
Note 2.
Guaranteed by design. Not tested in production.
PRODUCT ORDERING INFORMATION
Ordering
Code
Package
Type
Operating
Range
Marking
Code
SY10EPT20VZC
Z8-1
Commercial
HEP20
SY10EPT20VZCTR(1)
Z8-1
Commercial
SY100EPT20VZC
Z8-1
SY100EPT20VZCTR(1)
Package
Type
Operating
Range
Marking
Code
SY10EPT20VZI(2)
Z8-1
Industrial
HEP20
HEP20
SY10EPT20VZITR(1,2)
Z8-1
Industrial
HEP20
Commercial
XEP20
SY100EPT20VZI(2)
Z8-1
Industrial
XEP20
Z8-1
Commercial
XEP20
SY100EPT20VZITR(1,2)
Z8-1
Industrial
XEP20
SY10EPT20VKC
K8-1
Commercial
HP20
SY10EPT20VKI(2)
K8-1
Industrial
HP20
SY10EPT20VKCTR(1)
K8-1
Commercial
HP20
SY10EPT20VKITR(1,2)
K8-1
Industrial
HP20
SY100EPT20VKC
K8-1
Commercial
XP20
SY100EPT20VKI(2)
K8-1
Industrial
XP20
SY100EPT20VKCTR(1)
K8-1
Commercial
XP20
SY100EPT20VKITR(1,2)
K8-1
Industrial
XP20
Note 1.
Tape and Reel.
Note 2.
Recommended for new designs.
Ordering
Code
3
ECL Pro™
SY10EPT20V
SY100EPT20V
Micrel
8 LEAD PLASTIC SOIC (Z8-1)
Rev. 03
4
ECL Pro™
SY10EPT20V
SY100EPT20V
Micrel
8 LEAD MSOP (K8-1)
Rev. 01
MICREL, INC.
TEL
1849 FORTUNE DRIVE SAN JOSE, CA 95131
+ 1 (408) 944-0800
FAX
+ 1 (408) 944-0970
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2003 Micrel, Incorporated.
5