ETC BXA40-48T05-12-M

BXA40 Series
Triple output
DC/DC CONVERTERS
40W Wide Input DC/DC Converters
1
• Meets telecom power supply interface standard
ETS300-132-2
• EN60950, CSA950 and UL1950 safety approvals
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• Fixed frequency operation at 400kHz
• MTBF in excess of 500,000 hours
• Basic insulation system with 1500V isolation
• Pin-compatible with NFC40 Series
The BXA40-48T05-12-M provides 40 Watts of output power, has been conceived as an
applications-specific range of DC/DC converters, specifically addressing
telecommunications, industrial electronics, test equipment, mobile telecommunications
and distributed power applications. The series offers a wide input voltage range, of 3675VDC, and is available with a 5/±12V triple output. The BXA40 series is designed to
meet ETSI telecoms interface standard ETS300-132-2. With safety approval to IEC950
and basic insulation, the 48VDC model is ideal for telecommunications applications.
Other features include low output ripple, overvoltage protection, short circuit protection
and remote enable.
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Line regulation
(See Note 2)
Main output
Auxiliary output
±0.5%
±2.0%
Load regulation
(See Note 3)
Main output
Auxiliary output
±1.0%
±3.0% typ.,
±5.0% max.
Load cross regulation
(See Note 4)
Main output
Aux. output
±1.0%
±3.0% typ., ±5.0% max.
Ripple and noise
(20MHz bandwidth)
Main output
50mV pk-pk,
20mV rms
100mV pk-pk,
20mV rms
Auxiliary output
Temperature coefficient
±0.02%/°C
Overvoltage protection
transorbs fitted
Main output
Auxiliary outputs
Short circuit protection
(See Note 5)
Main output
Auxiliary output
Transient response
25% to 100% load
Voltage accuracy
Main output
Auxiliary output
Minimum Load
Main output
Auxiliary outputs
6.8V (nom.)
16/20V (nom.)
11A
5A
4.0%
±1.0%
±3.0%
0.6A
0.03A/0.04A
Input voltage range
48Vin nominal
36 to 75VDC
Reverse voltage
protection
External fuse
(See Note 7)
Start-up time
Remote ON/OFF
Logic compatibility
ON
OFF
Radiated emissions
ESD air
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
5V/ms
ETS300-132
30ms typ.
CMOS/TTL
Open-circuit
<1VDC
EN55022, FCC part 15,
(See Notes 6, 9)
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 4
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
Level B
Perf.
Perf.
Perf.
Perf.
Perf.
Perf.
Level A
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
criteria 1
GENERAL SPECIFICATIONS
Efficiency
83%
Isolation voltage
Input/output
Basic insulation, input/case
Switching frequency
Fixed
1500VDC
1500VDC
400kHz (typical)
Approvals and
standards (pending)
EN60950, UL1950
CSA C22.2 No. 950
Case material
Aluminum substrate
with plastic case
Material flammability
UL94V-0
Weight
MTBF
INPUT SPECIFICATIONS
Max. input rise and
fall time
Conducted emissions
85g typ. (3.0oz)
MIL-HDBK-217F
Size
500,000 hours
2.2 x 2.2 x 0.5 inches
55.9 x 55.9 x 12.7 mm
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Thermal impedance
(See Note 8)
Baseplate operating
temperature
Non-operating
-40°C to +105°C
-55°C to +105°C
No air flow, no heatsink
No air flow, with heatsink
8.5°C/W
7.2°C/W
File Name: BXA40T.PDF Rev: 02 Oct 2002
BXA40 Series
Triple output
DC/DC CONVERTERS
40W Wide Input DC/DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
CURRENT (MAX.)
36-75VDC
5V/±12V
6A/±0.4A
INPUT
CURRENT
TYPICAL
EFFICIENCY
(1)
30mA
MODEL NUMBER
83%
Notes
(10)
BXA40-48T05-12-M
PIN CONNECTIONS
1
2
3
Nominal line, at no load.
Nominal line to high line, nominal line to low line.
Load regulation:
Main output (V1): 25 to 100% with 25% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 25% to 100% balanced on all outputs.
4 Cross regulation:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): main output 100% load, auxiliary 100%,
other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other
auxiliary 25% to 100%.
5 Short circuit protection, ≤ 1 minute on auxiliary outputs.
6 For EMI compliance to EN55022 level B please consult factory for details.
For EMI compliance to EN55022 level A, refer to BXA40 Design Note 101.
7 Reverse voltage protection, refer to BXA40 Design Note 101.
8 The maximum operating ambient temperature, without derating depends
on internal power dissipation and module efficiency and cooling method.
Download BXA40 Design Note 101 which provides detailed thermal
calculations and design-in hints from the Artesyn website.
9 It is suggested that an external filter capacitor be used. A 4µF (or greater)
film capacitor such as: ITW Paktron Capstick series, part number
405K100CS4 4µF/100V is recommended, if filtering is not used. See BXA40
Design Note 101.
10 The unit with the suffix ‘-M’ at the end of the model number is offered as
standard with metric threaded inserts (M3). To order a unit with imperial
threaded inserts (4-40 UNC) please remove the suffix ‘-M’ from the model
number. These inserts are used for bolting the unit to a
PCB and/or fixing heatsinks.
11 A top mounted heatsink kit is available for the BXA40.
The heatsink may be oriented parallel to or
perpendicular to the direction of the pins, thus providing
0.019
optimum flexibility for cooling requirements. The order
(0.50)
number for the top mounted heatsink kit with metric
screws is ‘NFC40-HTSK-T’. The order number for the
top mounted heatsink kit with imperial screws is
‘NFC40-HTSK-T-I’.
PIN NUMBER
TRIPLE OUTPUT
1
+ Input
2
– Input
3
Control
4
+ Output (V2)
5
Common
6
- Output (V3)
7
+ Output (V1)
8
- Output (V1)
9
No Connection
1.90
(48.26)
0.15
(3.82)
1.25
(31.76)
0.60
(15.24)
0.2
(5.08)
3
2
1
0.043 ±0.003(1.02 ±0.05)
Diameter Typ.
Metric (Suffix '-M'):
M3 Tap Thru. 4 places or
Imperial (No '-M' suffix) 440 UNC (Optional)
1.80
(45.72)
1.90
(48.26)
2.20 ±0.02
(55.90 ±0.50)
0.256 (6.50) Diameter
Stand-off (4 Places)
9
0.50
(12.70)
8
7
6
0.15
(3.90)
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. 14501-3336-7009
Licence No. 6296
UL1950 File No. E174104
0.3
(7.62)
5
4
0.1
(2.54)
0.2
(5.08)
0.05
(1.27)
0.15
(3.82)
0.6
(15.24)
0.8
0.5
(20.32)
(12.70)
2.20 ±0.02
(55.90 ±0.50)
BOTTOM VIEW
ALL DIMENSIONS IN INCHES (mm)
TOLERANCE : ± 0.004 (0.1)
(Unless otherwise specified)
CSA C22.2 No. 950 File No. LR41062C
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ✔ Design Note
www.artesyn.com
File Name: BXA40T.PDF Rev: 02 Oct 2002