ETC 0298200.TX832

The MEGA® Fuse is designed for high current circuit
protection up to 250 amperes with “Diffusion Pill
Technology”, the Mega Fuse also provides time delay characteristics. Designed and patented by Littelfuse, the MEGA
Fuse is ideal for battery and alternator protection application and other heavy gauge cables requiring ultra-high
current protection.
80A
100A
125A
150A
175A
200A
225A
250A
MEGA® Fuse
1000
TIME IN SECONDS
100
10
1
.1
.01
10
100
1000
10000
100000
CURRENT IN AMPERES
1.0
Ø 8.6
R 11.9
298
32V
LITTELFUSE
®
MEGA
19.1
100A
PAT .5293147
29.2
50.8
9.9
68.6
TIME-CURRENT CHARACTERISTICS
Opening Time
% of
Maximum
Minimum
Rating
—
4 hrs.
110
1800 s
120 s
135
15 s
1s
200
5s
0.3 s
350
1s
0.1 s
600
Interrupting Rating: 2000A @ 32 VDC
Voltage Rating: 32 VDC
Ambient Temp.: –40°C to +125°C
MEGA® FUSE TABLE
14
Current
Rating
(A)
80
100
125
150
175
200
225
250
Nom. Cold
Resistance
(mΩ)
0.72
0.55
0.43
0.35
0.27
0.26
0.23
0.19
MEGA Fuse Temperature Rerating Curve
120
Rerating Factor (% Rated Current)
Part
Number
298080
298100
298125
298150
298175
298200
298225
298250
Typ. Voltage
Drop at
Rated Current
(mV)
87
87
80
92
86
83
82
82
115
110
105
100
95
90
85
80
75
70
-40
-20
0
20
40
60
80
100
Ambient Temperature (°C)
120
140