ETC G3NE-210T-US

9
Solid State Relay
G3NE
Compact, Low-cost, SSR Switching
5 to 20 A
1 Wide load voltage range: 75 to 264 VAC
1 Dedicated, compact aluminum PCB and
power elements used
1 Built-in varistor effectively absorbs
external surges.
1 Quick-connect #110 input terminals and
#250 output connections. (#187 input
terminals available)
èòð
1 Approved by UL and CSA
Ordering Information
To order: Select the part number and add the desired coil voltage rating, (e.g., G3NE-205T-US DC24)
Isolation
Zero cross
function
Indicator
Rated output load
(applicable output load)
Rated input voltage
Part number
Phototriac
Yes
No
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
5, 12, 24 VDC
G3NE-205T-US
No
10 A at 100 to 240 VAC
(10 A at 75 to 264 VAC)
G3NE-210T-US
20 A at 100 to 240 VAC
(20 A at 75 to 264 VAC)
G3NE-220T-US
5 A at 100 to 240 VAC
(5 A at 75 to 264 VAC)
G3NE-205TL-US
10 A at 100 to 240 VAC
(10 A at 75 to 264 VAC)
G3NE-210TL-US
20 A at 100 to 240 VAC
(20 A at 75 to 264 VAC)
G3NE-220TL-US
Note: For information on ordering #187 input terminals contact your local Omron representitve
3 ACCESSORIES (ORDER SEPARATELY)
Heat Sink
The following heat sinks are thin and can be track-mounted.
See Dimensions for details.
Part number
Applicable SSR
Y92B-N50
G3NE-205T(L)/-210T(L)
Y92B-N100
G3NE-220T(L)
G3NE
G3NE
Specifications
3 RATINGS
Input
Rated voltage
Operating voltage
Voltage level
Input impedance
Must operate
Must release
With zero cross function
Without zero cross
function
1 VDC min.
5 VDC
4 to 6 VDC
4 VDC max.
250 Ω ±20%
300 kΩ ±20%
12 VDC
9.6 to 14.4 VDC
9.6 VDC max.
600 Ω ±20%
800 kΩ ±20%
24 VDC
19.2 to 28.8 VDC
19.2 VDC max.
1.6 kΩ ±20%
Note:
Each model has 5-VDC, 12-VDC, and 24-VDC input versions.
Output
Part number
Applicable load
Rated load voltage
G3NE-205T(L)-US
75 to 264 VAC
Load current
Inrush current
With heat sink
Without heat sink
0.1 to 5 A
0.1 to 5 A
60 A (60 Hz, 1 cycle)
G3NE-210T(L)-US
0.1 to 10 A
(see note)
0.1 to 5 A
150 A (60 Hz, 1 cycle)
G3NE-220T(L)-US
0.1 to 20 A
(see note)
0.1 to 5 A
220 A (60 Hz, 1 cycle)
Note:
100 to 240 VAC
Load voltage
g range
g
These values apply when using a dedicated radiator or a radiation plate of specified size.
3 CHARACTERISTICS
Item
G3NE-2PPT-US
G3NE-2PPTL-US
Operate time
1/2 of load power source cycle + 1 ms max.
1 ms max.
Release time
1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
1.6 V (RMS) max.
Leakage current
5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Malfunction: 1,000 m/s2 {approx. 100G}
Ambient temperature
Operating: --30°C to 80°C (with no icing nor condensation)
Storage: --30°C to 100°C (with no icing nor condensation)
Ambient humidity
Operating: 45% to 85%
Approved standards
UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535
TÜV R9051064 (VDE0435) (EN60950)
Weight
Approx. 37 g
9
G3NE
G3NE
Engineering Data
Load Current vs. Ambient
Temperature Characteristics
G3NE-205T(L)-US
G3NE-210T(L)-US
With standard heat sink (Y92B-N100) or
aluminum plate measuring 300 mm x
300 mm x 2 mm (W x H x D)
Load current (A)
Without heat sink
Load current (A)
With standard heat sink (Y92B-N50)
or aluminum plate measuring 100 mm
x 100 mm x 2 mm (W x H x D)
Without heat sink
Load current (A)
G3NE-220T(L)-US
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Without heat sink
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
Energizing time (ms)
10
G3NE-220T(L)-US
Inrush current (A. Peak)
G3NE-210T(L)-US
Inrush current (A. Peak)
Inrush current (A. Peak)
G3NE-205T(L)-US
Energizing time (ms)
Energizing time (ms)
G3NE
G3NE
Dimensions
Unit: mm (inch)
G3NE-205T(L)/210T(L)/220T(L)-US
3.5 dia. hole
Terminal Arrangement/
Internal Connections
(Top View)
47.5
max.
37.5 max.
14.5
3+
1
30±0.5
Input
voltage
Two #110 (t = 0.5) (Faston
tab or equivalent)
6.5
Input
Two #250 (t = 0.8) (Faston
tab or equivalent)
7.1
2.9
Input
4 --
Load
2
7.95
6
11.5 max.
3
Mounting Holes
Two, 3.5-dia. or M3 holes
30±0.2
Heat Sink
Y92B-N50
Load power
supply
Mounting Holes
4.6 dia.
Two, M3 holes
Two, M4 holes
35±0.2
Two, 3.2-dia.
holes
44 max. 30
35 30.5±0.3
47.6
47 max.
Two, 4.4-dia.
or M4 holes
90±0.4
5.6
5
4.5
6
77 max.
51 max.
90±0.3
100 max.
Weight: approx. 200 g
Y92B-N100
4.6 dia.
Two, M3 holes
Mounting Holes
Two, M4
holes
Two, 3.2-dia. holes
35±0.2
71 max.
35 30.5±0.3
30
75 max.
Two, 4.4-dia.
or M4 holes
90±0.4
47.6
77 max.
5.6
28
5
13
4.5
100 max.
90±0.3
100 max.
Weight: approx. 400 g
11
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
9
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
01/00
Specifications subject to change without notice.
Printed in U.S.A.