ETC 82-100A-C

Model 82 UltraStable
316L SS Pressure Sensor
High Performance, 19 mm
0-100 mV Output
Absolute and Gage
Low Pressure
Hydraulic Controls
Process Control
Oceanography
Refrigeration/Compressors
Pressure Transmitters
Level Systems
DESCRIPTION
The Model 82 is a 19 mm small profile, media compatible,
piezoresistive silicon pressure sensor packaged in a 316L
stainless steel housing. The Model 82 is designed for O-ring
mounting. The sensing package utilizes silicone oil to transfer
pressure from the 316L stainless steel diaphragm to the sensing
element.
The Model 82 is designed for high performance, low
pressure applications. A ceramic substrate is attached to the
package that contains laser-trimmed resistors for temperature
compensation and offset correction. An additional lasertrimmed resistor is included which can be used to adjust an
external differential amplifier and provide span
interchangeability to within ±1%.
Sensors with threaded pressure fittings, weldable flush
FEATURES
sensors and high pressure stainless steel sensors are also
O-Ring Flush Mount
–20°C to +85°C Compensated
Temperature Range
±0.1% Pressure Non-linearity
±1.0% Interchangeable Span
(provided by gain set resistor)
Solid State Reliability
Low Power
available. Please contact the factory for more information.
DIMENSIONS
STANDARD RANGES
Range
0 to 5
1-62
psig
psia
Contact Factory
0 to 15
●
●
0 to 30
●
●
0 to 50
●
●
0 to 100
●
●
0 to 300
●
●
0 to 500
●
●
ISO – Wide Temperature Range
Model 82 UltraStable
316L SS Pressure Sensor
PERFORMANCE SPECIFICATIONS
All parameters specified at 1.5mA and at 25°C, after 10 second warm up, unless otherwise indicated. Unless specifically indicated, only those parameters
indicated as tested are verified on each part. Parameters are specified for the compensated version only.
PARAMETERS
MIN
TYP
MAX
UNITS
NOTES
Full Scale Output Span
75
100
150
mV
1
Zero Pressure Output (Offset)
–1
0
1
mV
2
0.10
±% Span
3
Pressure Non Linearity
–0.10
Pressure Hysteresis
–0.05
0.02
Repeatability
+0.05
±% Span
0.02
Ω
Input Resistance
2000
Output Resistance
4000
25000
Ω
Temperature Error - Span (–20 to +85°C)
–0.75
+0.75
% Span
4
–0.5
+0.5
% Span
4, 5
Temperature Error - Offset (–20 to +85°C)
3500
±% Span
4500
Thermal Hysteresis - Span
0.05
% Span
4
Thermal Hysteresis - Offset
0.05
% Span
4
0.1
±% Span/year
Long Term Stability - Span
Long Term Stability - Offset
0.1
Supply Current
0.5
Output Load Resistance
Insulation Resistance (50 VDC)
1.5
±% Span/year
mA
6
5
MΩ
7
50
MΩ
8
Pressure Overload
2.0
3X
Rated
Compensated Temperature Range
–20°C to +85°C
9
Operating Temperature Range
–40°C to +125°C
9
Storage Temperature Range
–50°C to +125°C
9
Media - Pressure Port
Liquids and Gases compatible with 316L Stainless Steel
Media - Reference Port
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and
316L Stainless Steel
Weight
12 g
Notes
1. For amplified output circuits see application note TN-003.
6.
Guarantees output/input ratiometricity.
2.
Measured at vacuum for absolute (A), ambient for gage (G).
7.
Load resistance to reduce measurement errors due to output loading.
3.
Best fit straight line.
8.
Between case and sensing element.
4.
Over the temperature range –20°C to +85°C with respect to +25°C.
9.
5.
15 psi range sensors have an offset temperature error of ±0.75%
(Max) from –20°C to +85°C.
Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
ORDERING INFORMATION
10. For gage units used at pressures below atmosphere, the span accuracy
is not guaranteed.
APPLICATION SCHEMATIC
CONNECTIONS
PAD/CONDUCTOR NO
FUNCTION
1
+OUT
2
-EX
3
+EX
4
-OUT
5
GAIN
6
GAIN
ISO – Wide Temperature Range
June 2001
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
1-63