AD ADIS16135/PCBZ

±300°/Sec
Precision Angular Rate Sensor
ADIS16135
FEATURES
GENERAL DESCRIPTION
Digital gyroscope system, ±300°/sec measurement range
In-run bias stability, ~6°/hour
~11°/hour over temperature: −40°C to +85°C
Autonomous operation and data collection
No external configuration commands required
Start-up time: 181 ms; sleep mode recovery: 5 ms
Factory-calibrated sensitivity and bias
Calibration temperature range: −40°C to +85°C
Single serial peripheral interface, SPI compatible
Wide bandwidth: 335 Hz
Embedded temperature sensor
Programmable operation and control
Automatic and manual bias correction controls
Digital filters: Bartlett FIR, average/decimation
Internal sample rate: up to 2048 SPS
Digital I/O: data ready, alarm indicator, general-purpose
Alarms for condition monitoring
Sleep mode for power management
Enable external sample clock input: up to 2048 Hz
Single-supply operation: 4.85 V to 5.15 V
2000 g shock survivability
Operating temperature range: −40°C to +105°C
The ADIS16135 iSensor® is a high performance, digital gyroscope sensing system that operates autonomously and requires
no user configuration to produce accurate rate sensing data. It
provides performance advantages with low noise density, wide
bandwidth, and excellent in-run bias stability, which are
enabling for applications such as platform control, navigation,
robotics, and medical instrumentation.
This sensor system combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic
performance. The factory calibration characterizes the entire
sensor signal chain for sensitivity and bias over a temperature
range of −40°C to +85°C. As a result, each ADIS16135 has its
own unique correction formulas to produce accurate measurements upon installation. For some systems, the factory calibration
eliminates the need for system-level calibration and greatly
simplifies it for others.
The ADIS16135 samples data at rates of up to 2048 SPS and
offers an averaging/decimation filter structure for optimizing
noise/bandwidth trade-offs. The serial peripheral interface (SPI)
and user register structure provide easy access to configuration
controls and calibrated sensor data for embedded processor
platforms.
APPLICATIONS
The 36 mm × 44 mm × 14 mm package provides four holes for
simple mechanical attachment, using M2 (or 2-56 standard size)
machine screws along with a standard 24-pin, dual-row, 1 mm
pitch connector that supports electrical attachment to a printed
circuit board or cable system. The ADIS16135 provides an
operating temperature range of −40°C to +105°C.
Precision instrumentation
Platform stabilization and control
Industrial vehicle navigation
Downhole instrumentation
Robotics
FUNCTIONAL BLOCK DIAGRAM
VCC
DIO1 DIO2 CLKIN RST
SELF-TEST
I/O
ALARMS
MEMS
SENSOR
CONTROLLER
POWER
MANAGEMENT
USER
CONTROL
REGISTERS
CS
TEMP
SENSOR
CLOCK
SPI
PORT
CALIBRATION
FILTER
ADIS16135
SCLK
DIN
DOUT
08888-001
OUTPUT
DATA
REGISTERS
GND
Figure 1.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2010 Analog Devices, Inc. All rights reserved.
ADIS16135
TABLE OF CONTENTS
Features .............................................................................................. 1
Digital Processing Configuration ................................................. 11
Applications ....................................................................................... 1
Calibration ....................................................................................... 12
General Description ......................................................................... 1
Alarms .............................................................................................. 13
Functional Block Diagram .............................................................. 1
System Controls .............................................................................. 14
Revision History ............................................................................... 2
Global Commands ..................................................................... 14
Specifications..................................................................................... 3
Memory Management ............................................................... 14
Timing Specifications .................................................................. 4
General-Purpose I/O ................................................................. 14
Timing Diagrams.......................................................................... 4
Self-Test ....................................................................................... 15
Absolute Maximum Ratings............................................................ 5
Power Management ................................................................... 15
ESD Caution .................................................................................. 5
Status ............................................................................................ 15
Pin Configuration and Function Descriptions ............................. 6
Product Identification................................................................ 16
Typical Performance Characteristics ............................................. 7
Applications Information .............................................................. 17
Basic Operation................................................................................. 8
Prototype Interface Board ......................................................... 17
Reading Sensor Data .................................................................... 8
Installation Tips .......................................................................... 17
Output Data Registers .................................................................. 9
Outline Dimensions ....................................................................... 18
Device Configuration .................................................................. 9
Ordering Guide .......................................................................... 18
User Registers .................................................................................. 10
REVISION HISTORY
4/10—Revision 0: Initial Version
Rev. 0 | Page 2 of 20
ADIS16135
SPECIFICATIONS
TA = 25°C, VCC = 5.0 V, angular rate = 0°/sec, dynamic range = ±300°/sec ± 1 g, unless otherwise noted.
Table 1.
Parameter
GYROSCOPES
Dynamic Range
Initial Sensitivity
Sensitivity Temperature Coefficient
Nonlinearity
Initial Bias Error
In-Run Bias Stability
Angular Random Walk
Linear Acceleration Effect on Bias
Bias Voltage Sensitivity
Output Noise
Rate Noise Density
3 dB Bandwidth
Sensor Resonant Frequency
Self-Test Change in Output Response
LOGIC INPUTS1
Input High Voltage, VIH
Input Low Voltage, VIL
Logic 1 Input Current, IIH
Logic 0 Input Current, IIL
All Pins Except RST
RST Pin
Input Capacitance, CIN
DIGITAL OUTPUTS1
Output High Voltage, VOH
Output Low Voltage, VOL
FLASH MEMORY
Data Retention2
FUNCTIONAL TIMES3
Power-On Start-Up Time
Reset Recovery Time
Sleep Mode Recovery Time
Flash Memory Self-Test
Automatic Sensor Self-Test Time
CONVERSION RATE
Clock Accuracy
Sync Input Clock
POWER SUPPLY
Power Supply Current
Test Conditions/Comments
GYRO_OUT register only
−40°C ≤ TA ≤ +85°C
Best fit straight line
±1 σ
+25°C, SMPL_PRD = 0x001F
1 σ, +25°C
1σ
VCC = 4.85 V to 5.15 V
SMPL_PRD = 0x001F
f = 25 Hz, SMPL_PRD = 0x001F
GYRO_OUT register only
Min
Typ
±300
0.012375
±350
0.0125
±16
±0.008
±1
0.0017
0.75
0.03
0.02
0.27
0.0122
335
14.5
6080
3380
Max
8780
°/sec
°/sec/LSB
ppm/°C
% of FS
°/sec
°/sec
°/√hr
°/sec/g
°/sec/V
°/sec rms
°/sec/√Hz rms
Hz
kHz
LSB
0.8
±1
V
V
μA
0.012625
2.0
VIH = 3.3 V
VIL = 0 V
±0.2
40
80
10
ISOURCE = 1.6 mA
ISINK = 1.6 mA
Endurance2
TJ = 85°C
Time until data is available
0.4
10,000
20
181
74
4.7
16
46
680
SMPL_PRD = 0x001F
SMPL_PRD = 0x0000
Operating voltage range, VCC
SMPL_PRD = 0x001F
Sleep mode
1
6804
4.85
5.0
88
1.4
The digital I/O signals are driven by an internal 3.3 V supply, and the inputs are 5 V tolerant.
JEDEC Standard 22, Method A117. Endurance measured at −40°C, +25°C, +85°C, and +125°C.
These times do not include thermal settling and internal filter response times (340 Hz bandwidth), which may affect overall accuracy.
4
The sync input clock and internal sampling clock function below the specified minimum value, at reduced performance levels.
2
3
Rev. 0 | Page 3 of 20
60
2.4
SMPL_PRD = 0x000F
SMPL_PRD = 0x000F
Unit
2048
±3
2048
5.25
μA
μA
pF
V
V
Cycles
Years
ms
ms
ms
ms
ms
kSPS
%
kHz
V
mA
mA
ADIS16135
TIMING SPECIFICATIONS
TA = 25°C, VCC = 5 V, unless otherwise noted.
Table 2.
Parameter
fSCLK
tSTALL
tREADRATE
t
tDAV
tDSU
tDHD
tSCLKR, tSCLKF
tDR, tDF
tSFS
t1
tx
t2
t3
Description
Serial clock
Stall period between data
Read rate
Chip select to clock edge
DOUT valid after SCLK edge
DIN setup time before SCLK rising edge
DIN hold time after SCLK rising edge
SCLK rise/fall times
DOUT rise/fall times
CS high after SCLK edge
Input sync positive pulse width
Input sync low time
Input sync to data ready output
Input sync period
CS
1
Normal Mode
Typ
Max
2.0
Min1
0.01
9
25
48.8
Unit
MHz
µs
µs
ns
ns
ns
ns
ns
ns
ns
µs
µs
µs
µs
25
24.4
48.8
5
5
12.5
12.5
0
5
100
360
488
Guaranteed by design and characterization but not tested in production.
TIMING DIAGRAMS
CS
tCS
tSFS
1
2
3
4
5
6
15
16
SCLK
tDAV
MSB
DB14
DIN
R/W
A6
DB12
DB11
A4
A3
DB13
tDSU
DB10
DB2
DB1
LSB
tDHD
A5
D2
A2
D1
08888-002
DOUT
LSB
Figure 2. SPI Timing and Sequence
tREADRATE
tSTALL
08888-003
CS
SCLK
Figure 3. Stall Time and Data Rate
t3
t2
t1
tX
08888-004
SYNC
CLOCK (CLKIN)
DATA
READY
Figure 4. Input Clock Timing Diagram
Rev. 0 | Page 4 of 20
ADIS16135
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
Acceleration
Any Axis, Unpowered
Any Axis, Powered
VCC to GND
Digital Input Voltage to GND
Digital Output Voltage to GND
Operating Temperature Range
Storage Temperature Range
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Rating
2000 g
2000 g
−0.3 V to +7.0 V
−0.3 V to +5.3 V
−0.3 V to VCC + 0.3 V
−40°C to +105°C
−65°C to +125°C1, 2
Table 4. Package Characteristics
Extended exposure to temperatures outside the specified temperature
range of −40°C to +105°C can adversely affect the accuracy of the factory
calibration. For best accuracy, store the parts within the specified operating
range of −40°C to +105°C.
2
Although the device is capable of withstanding short-term exposure to
150°C, long-term exposure threatens internal mechanical integrity.
1
Package Type
24-Lead Module (ML-24-3)
ESD CAUTION
Rev. 0 | Page 5 of 20
θJA
15.7
θJC
1.48
Device Weight
25 g
ADIS16135
PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
RATE
AXIS
POSITIVE
ROTATION
DIRECTION
+
ADIS16135
08888-006
TOP VIEW
Figure 6. Axial Orientation (Bottom Side Facing Up)
2
4
6
8
10 12 14 16 18 20 22 24
1
3
5
7
9
08888-005
11 13 15 17 19 21 23
NOTES
1. PINS ARE NOT VISIBLE FROM THIS VIEW. THE PIN ASSIGNMENTS
SHOWN REPRESENT THE MATING CONNECTOR ASSIGNMENTS.
Figure 5. Mating Connector Pin Assignments
Table 5. Pin Function Descriptions
Pin No.
2
3
4
5
6
7
8
9
10, 11, 12
13, 14, 15
1, 16 to 24
1
Mnemonic
CLKIN
SCLK
DOUT
DIN
CS
DIO1
RST
DIO2
VCC
GND
DNC
Type1
I
I
O
I
I
I/O
I
I/O
S
S
N/A
Description
Clock Input, SMPL_PRD = 0x0000
SPI Serial Clock.
SPI Data Output. Clocks output on SCLK falling edge.
SPI Data Input. Clocks input on SCLK rising edge.
SPI Chip Select.
Configurable Digital Input/Output.
Reset.
Configurable Digital Input/Output.
Power Supply.
Power Ground.
Do Not Connect.
I/O is input/output, I is input, O is output, S is supply, N/A is not applicable.
Rev. 0 | Page 6 of 20
ADIS16135
TYPICAL PERFORMANCE CHARACTERISTICS
0.1
0.15
GYRO BIAS (°/sec)
(°/sec)
0.10
0.01
0.05
0
0.05
1
10
100
1k
10k
Tau (sec)
Figure 7. Gyroscope Allan Variance, +25°C
MEAN – 1σ
1
10
100
1k
Tau (sec)
10k
08888-008
(°/sec)
MEAN
MEAN + 1σ
0.001
0
10
20
30
40
50
60
70
TEMPERATURE (°C)
Figure 9. Bias vs. Temperature, 0.1°C/Min Ramp Rate,
Autonull at +25°C, SMPL_PRD = 0x001F,
DEC_RATE = 0x0010
0.1
0.01
0.15
–40 –30 –20 –10
Figure 8. Allan Variance, 0°C to +50°C, 1°C/Min Ramp Rate
Rev. 0 | Page 7 of 20
80
08888-024
0.001
08888-007
0.10
ADIS16135
BASIC OPERATION
Table 7. Generic Master Processor SPI Settings
The ADIS16135 is an autonomous system that requires no user
initialization. Once it has a valid power supply, it initializes itself
and starts sampling, processing, and loading sensor data into
the output registers. DIO1 pulses high after each sample cycle
concludes. The SPI interface enables simple integration with
many embedded processor platforms, as shown in Figure 10
(electrical connection) and Table 6 (processor pin descriptions).
5V
A single register read requires two 16-bit SPI cycles. The first
cycle requests the contents of a register using the bit assignments
in Figure 13. Then the register contents follow on DOUT
during the second sequence. Figure 11 includes three single
register reads in succession. In this example, the process starts
with DIN = 0x0600 to request the contents of the GYRO_OUT
register and follows with 0x0400 to request the contents of the
GYRO_OUT2 register and with 0x0200 to request the contents
of the TEMP_OUT register. Full duplex operation enables
processors to use the same 16-bit SPI cycle to read data from
DOUT while requesting the next set of data on DIN. Figure 12
provides an example of the four SPI signals when reading
GYRO_OUT in a repeating pattern.
ADIS16135
SS
6
CS
SCLK
3
SCLK
MOSI
5
DIN
MISO
4
DOUT
IRQ
7
DIO1
14
13
15
Figure 10. Electrical Connection Diagram
Table 6. Generic Master Processor Pin Names and Functions
Pin Name
SS
IRQ
MOSI
MISO
SCLK
Function
Slave select
Interrupt request
Master output, slave input
Master input, slave output
Serial clock
DIN
0x0600
DOUT
0x0400
0x0200
GYRO_OUT
GYRO_OUT2
TEMP_OUT
Figure 11. SPI Read Example
The ADIS16135 SPI interface supports full duplex serial
communication (simultaneous transmit and receive) and uses
the bit sequence shown in Figure 13. Table 7 provides a list of
the most common settings that require attention to initialize a
processor’s serial port for the ADIS16135 SPI interface.
CS
SCLK
DIN
DIN = 0000 0110 0000 0000 = 0x0600
DOUT
DOUT = 1111 1001 1101 1010 = 0xF9DA = –1574 LSBs ≥ –19.675°/sec
Figure 12. SPI Read Example, Second 16-Bit Sequence
CS
DOUT
R/W
D15
A6
A5
A4
A3
A2
A1
A0
DC7
DC6
DC5
DC4
DC3
DC2
DC1
DC0
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
R/W
D15
A6
A5
D14
D13
NOTES
1. DOUT BITS ARE PRODUCED ONLY WHEN THE PREVIOUS 16-BIT DIN SEQUENCE STARTS WITH R/W = 0.
2. WHEN CS IS HIGH, DOUT IS IN A THREE-STATE, HIGH-IMPEDANCE MODE, WHICH ALLOWS MULTIFUNCTIONAL USE OF THE LINE
FOR OTHER DEVICES.
Figure 13. SPI Communication Bit Sequence
Rev. 0 | Page 8 of 20
08888-013
SCLK
DIN
08888-011
SYSTEM
PROCESSOR
SPI MASTER
READING SENSOR DATA
12
11
10
Description
The ADIS16135 operates as a slave.
Maximum serial clock rate.
CPOL = 1 (polarity), CPHA = 1 (phase).
Bit sequence.
Shift register/data length.
08888-012
I/O LINES ARE COMPATIBLE WITH
3.3V OR 5V LOGIC LEVELS
08888-010
VDD
Processor Setting
Master
SCLK Rate ≤ 2 MHz
SPI Mode 3
MSB-First Mode
16-Bit Mode
ADIS16135
OUTPUT DATA REGISTERS
Table 12. TEMP_OUT Bit Descriptions
Table 8. Output Data Register Formats
Bits
[15:0]
Address
0x02
0x04
0x06
Measurement
Internal temperature
Gyroscope, lower 16 bits
Gyroscope, upper 16 bits
Table 13. Temperature, Twos Complement Format
Rotation Rate (Gyroscope)
GYRO_OUT is the primary register for gyroscope output data
and uses 16-bit twos complement format for its data. Table 9
provides the numerical format, and Table 10 provides several
examples for converting digital data into °/sec.
Table 9. GYRO_OUT Bit Descriptions
Bits
[15:0]
Description
Gyroscope data; twos complement,
0.0125°/sec per LSB, 0°/sec = 0x0000
Decimal
+24,000
+2
+1
0
−1
−2
−24,000
Hex
0x5DC0
0x0002
0x0001
0x0000
0xFFFF
0xFFFE
0xA240
Decimal
+1810
+2
+1
0
−1
−2
−690
Hex
0x712
0x0002
0x0001
0x0000
0xFFFF
0xFFFE
0xFD4E
Binary
0000 0111 0001 0010
0000 0000 0000 0010
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 1111 1111 1110
1111 1101 0100 1110
DEVICE CONFIGURATION
Table 10. GYRO_OUT, Twos Complement Format
Rotation Rate
+300°/sec
+0.025°/sec
+0.0125°/sec
0°/sec
−0.0125°/sec
−0.025°/sec
−300°/sec
Temperature
+105°C
+0.116°C
+0.058°C
0°C
−0.058°C
−0.116°C
−40°C
Binary
0101 1101 1100 0000
0000 0000 0000 0010
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 1111 1111 1110
1010 0010 0100 0000
The control registers listed in Table 14 provide a variety of user
configuration options. The SPI provides access to these registers,
one byte at a time, using the bit assignments shown in Figure 13.
Each register has 16 bits, where Bits[7:0] represent the lower
address and Bits[15:8] represent the upper address. Figure 15
provides an example of writing 0x03 to Address 0x22
(DEC_RATE[7:0]), using DIN = 0xA203. This example reduces
the sample rate by a factor of 8 (see Table 16).
CS
SCLK
DIN
The GYRO_OUT2 register (see Table 11) captures the bit growth
associated with the decimation filter shown in Figure 18, using
a MSB-justified format. The bit growth starts with the MSB
(GYRO_OUT2[15]), is equal to the decimation rate setting in
DEC_RATE[4:0] (see Table 18), and grows in the LSB direction
as the decimation rate increases. See Figure 14 for more details.
Description
Rotation rate data; resolution enhancement bits
D
GYROSCOPE DATA
15
GYRO_OUT
D = DEC_RATE[4:0]
NOT USED
0 15
GYRO_OUT2
0.0125 °/sec
BIT WEIGHT =
LSB = GYRO_OUT2[16-D]
LSB
2D
0
08888-014
Bits
[15:0]
Figure 15. SPI Sequence for Setting the Decimate Rate to 8 (DIN = 0xA203)
Dual Memory Structure
Writing configuration data to a control register updates its SRAM
contents, which are volatile. After optimizing each relevant control
register setting in a system, set GLOB_CMD[3] = 1 (DIN =
0xA808) to back these settings up in nonvolatile flash memory.
The flash backup process requires a valid power supply level for
the entire 72 ms process time. Table 14 provides a user register
memory map that includes a column of flash backup information.
A yes in this column indicates that a register has a mirror location
in flash and, when backed up properly, automatically restores itself
during startup or after a reset. Figure 16 provides a diagram of the
dual-memory structure used to manage operation and store critical
user settings.
Figure 14. Gyroscope Output Format, DEC_RATE[4:0] > 0
MANUAL
FLASH
BACKUP
Internal Temperature
The TEMP_OUT register (see Table 12) provides an internal
temperature measurement that can be useful for observing
relative temperature changes in the environment. Table 13
provides several coding examples for converting the 16-bit
twos complement number into units for temperature (°C).
VOLATILE
SRAM
NONVOLATILE
FLASH MEMORY
SPI ACCESS
(NO SPI ACCESS)
START-UP
RESET
Figure 16. SRAM and Flash Memory Diagram
Rev. 0 | Page 9 of 20
08888-016
Table 11. GYRO_OUT2 Bit Descriptions
DIN = 1010 0010 0000 0011 = 0xA203, WRITES 0x03 TO ADDRESS 0x22
08888-015
Register
TEMP_OUT
GYRO_OUT2
GYRO_OUT
Description
Temperature data; twos complement, 0.058°C per LSB,
0°C = 0x0000
ADIS16135
USER REGISTERS
Table 14. User Register Memory Map
Name
FLASH_CNT
TEMP_OUT
GYRO_OUT2
GYRO_OUT
GYRO_OFF2
GYRO_OFF
ALM_MAG1
ALM_MAG2
ALM_SMPL1
ALM_SMPL2
ALM_CTRL
GPIO_CTRL
MSC_CTRL
SMPL_PRD
AVG_CNT
DEC_RATE
SLP_CTRL
DIAG_STAT
GLOB_CMD
Reserved
LOT_ID1
LOT_ID2
LOT_ID3
PROD_ID
SERIAL_NUM
1
R/W
R
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
W
R
W
N/A
R
R
R
R
R
Flash Backup
Yes
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
N/A
Yes
Yes
Yes
Yes
Yes
Address1
0x00
0x02
0x04
0x06
0x08
0x0A
0x10
0x12
0x14
0x16
0x18
0x1A
0x1C
0x1E
0x20
0x22
0x24
0x26
0x28
0x26 to 0x31
0x32
0x34
0x36
0x38
0x3A
Default
N/A
N/A
N/A
N/A
0x0000
0x0000
0x0000
0x0000
0x0000
0x0000
0x0317
0x0000
0x0006
0x001F
0x0000
0x0000
0x0000
0x0000
0x0000
N/A
N/A
N/A
N/A
0x3F07
N/A
Register Description
Flash memory write count
Output, temperature (internal)
Output, gyroscope, lower 16 bits
Output, gyroscope, upper 16 bits
Gyroscope bias correction, lower 16 bits
Gyroscope bias correction, upper 16 bits
Alarm 1 trigger setting
Alarm 2 trigger setting
Alarm 1 sample period
Alarm 2 sample period
Alarm configuration
Auxiliary digital input/output control
Miscellaneous control: data ready, self-test
Internal sample period (rate) control
Digital filter control
Decimation rate setting
Sleep mode control
System status
System command
Reserved
Lot Identification Code 1
Lot Identification Code 2
Lot Identification Code 3
Product ID, binary number for 16,135
Serial number
Bit Function
Table 30
Table 12
Table 11
Table 9
Table 21
Table 20
Table 23
Table 24
Table 25
Table 25
Table 26
Table 32
Table 31
Table 16
Table 17
Table 18
Table 33
Table 34
Table 29
Table 35
Table 35
Table 35
Table 37
Table 36
Each register contains two bytes. The Address column in this table only offers the address of the lower byte. Add 1 to it to calculate the address of the upper byte.
Rev. 0 | Page 10 of 20
ADIS16135
DIGITAL PROCESSING CONFIGURATION
0
Address
0x1E
0x20
0x22
Description
Sample rate control
Digital filtering and range control
Decimation rate setting
SMPL _ PRD =
32,768
− 1; FS ≤ 2048 SPS
( FS )
The factory default setting for SMPL_PRD sets the internal
sample rate to a rate of 1024 SPS; the minimum setting for the
SMPL_PRD register is 0x000F, which results in an internal
sample rate of 2048 SPS.
Table 16. SMPL_PRD Bit Descriptions
Bits
[15:0]
Description (Default = 0x001F)
Clock setting bits; sets FS in Figure 18
Input Clock Configuration
Set SMPL_PRD = 0x0000 (DIN = 0x9F00, then DIN = 0x9E00)
to disable the internal clock and enable CLKIN as a clock input pin.
Digital Filtering
The AVG_CNT register (see Table 17) provides user controls
for the low-pass filter. This filter contains two cascaded averaging
filters that provide a Bartlett window FIR filter response (see
Figure 18). For example, set AVG_CNT[7:0] = 0x04 (DIN =
0xA004) to set each stage to 16 taps. When used with the default
sample rate of 1024 SPS, this establishes a −3dB bandwidth of
approximately 20 Hz for this filter.
MEMS
GYRO
–80
–100
N=2
N=4
N = 16
N = 64
–120
Internal Sample Rate
The SMPL_PRD register in Table 16 provides a programmable
control for the internal sample rate. Use the following formula
to calculate the decimal number for the code to write into this
register:
–60
–140
0.001
0.01
0.1
1
FREQUENCY (f/fS)
Figure 17. Bartlett Window FIR Filter Frequency Response
(Phase Delay = N Samples)
Table 17. AVG_CNT Bit Descriptions
Bits
[15:3]
[2:0]
Description (Default = 0x0000)
Don’t care
Binary; B variable in Figure 18; maximum = 110 (6)
Averaging/Decimation Filter
The DEC_RATE register (see Table 18) provides user control
for the final filter stage (see Figure 18), which averages and
decimates the output data. For systems that value lower sample
rates, this filter stage provides an opportunity to lower the sample
rate while maintaining optimal bias stability performance. The
−3 dB bandwidth of this filter stage is approximately one half
the output data rate. For example, set DEC_RATE[7:0] = 0x04
(DIN = 0xA204) to reduce the sample rate by a factor of 16.
When the factory default 1024 SPS sample rate is used, this
decimation setting reduces the output data rate to 64 SPS and
the sensor bandwidth to approximately 31 Hz.
Table 18. DEC_RATE Bit Descriptions
Bits
[15:5]
[4:0]
Description (Default = 0x0000)
Don’t care
Binary; D variable in Figure 18; maximum = 1000 (16)
÷ND
402Hz
819Hz
–3dB BANDWIDTH = 340Hz
32,768
SP + 1
SP ≥ 15
SP = SMPL_PRD
FS =
CLOCK
FS
B = SENS_AVG[2:0]
NB = 2B
NB = NUMBER OF TAPS PER STAGE
D = DEC_RATE[4:0]
ND = 2D
ND = NUMBER OF TAPS
ND = DATA RATE DIVISOR
CLKIN
Figure 18. Sampling and Frequency Response Block Diagram
Rev. 0 | Page 11 of 20
08888-018
Register Name
SMPL_PRD
AVG_CNT
DEC_RATE
–40
08888-017
Table 15. Digital Processing Registers
–20
MAGNITUDE (dB)
Figure 18 provides a block diagram for the sampling and digital
filter stages inside the ADIS16135. Table 15 provides a summary
of registers for sample rate and filter control.
ADIS16135
CALIBRATION
The ADIS16135 factory calibration produces correction
formulas for the gyroscope and programs them into the flash
memory. Table 19 contains a list of user control registers that
provide opportunity for user optimization after installation.
Figure 19 illustrates the summing function of the sensor’s offset
correction register.
Table 19. Registers for User Calibration
MEMS
GYRO
Address
0x08
0x0A
0x28
ADC
Description
Gyroscope bias
Gyroscope bias
Bias correction command
FACTORY
CALIBRATION
AND
FILTERING
GYRO_OUT GYRO_OUT2
08888-019
Register
GYRO_OFF2
GYRO_OFF
GLOB_CMD
GYRO_OFF GYRO_OFF2
Figure 19. Gyroscope Bias Calibration User Controls
The factory calibration addresses initial and temperature
dependent bias errors in the gyroscopes, but some
environmental conditions, such as temperature cycling and
mechanical stress on the package, can cause bias shifts in
MEMS gyroscope structures. For systems that value absolute
bias accuracy, there are two options for optimizing absolute bias
accuracy: autonull and manual correction.
The Allan variance curve shown in Figure 7 provides a trade-off
between bias accuracy and averaging time. The DEC_RATE
register provides a user control for averaging time when using
the ABC function. Set DEC_RATE[7:0] = 0x10 (DIN = 0xA210),
which sets the decimation rate to 65,536 (216) and provides an
averaging time of 64 seconds (65,536 ÷ 1024 SPS) for this
function. Then, set GLOB_CMD[0] = 1 (DIN = 0xA801), and
keep the platform stable for at least 65 seconds while the
gyroscope bias data accumulates.
After this completes, the ADIS16135 automatically updates the
flash memory. Once the ABC function starts, the SPI is not
active. The only way to interrupt it is to remove power or
initiate a hardware reset using the RST pin. When using
DEC_RATE = 0x0010, the 1 σ accuracy for this correction is
approximately 0.005°/sec for the gyroscope correction factor.
See Table 29 for more information on GLOB_CMD.
Manual Bias Correction
The GYRO_OFF and GYRO_OFF2 registers (see Table 20 and
Table 21) provide a bias adjustment function for the output of
each sensor. GYRO_OFF has the same format as GYRO_OUT,
and GYRO_OFF2 has the same format as GYRO_OUT2.
Table 20. GYRO_OFF Bit Descriptions
Bits
[15:0]
Automatic Bias Correction
Set GLOB_CMD[0] = 1 (DIN = 0xA801) to start the automatic
bias correction (ABC) function, which uses the following
internal sequence to calibrate each gyroscope for bias error:
1.
2.
3.
4.
5.
Wait for a complete output data cycle to complete, which
includes the entire average and decimation time in
DEC_RATE.
Read the gyroscope’s output registers.
Multiply the measurement by −1 to change its polarity.
Write the final value into the offset registers.
Update the flash memory.
Description (Default = 0x0000)
Gyroscope offset correction; twos complement,
0.0125°/sec per LSB
Table 21. GYRO_OFF2 Bit Descriptions
Bits
[15:0]
Description (Default = 0x0000)
Gyroscope offset correction, finer resolution; uses
same format as GYRO_OUT2 (see Table 11)
Restoring Factory Calibration
Set GLOB_CMD[1] = 1 (DIN = 0xA802) to execute the factory
calibration restore function. This function resets each user
calibration register to 0x0000, resets all sensor data to 0, and
automatically updates the flash memory within 72 ms. See
Table 29 for more information on GLOB_CMD.
Rev. 0 | Page 12 of 20
ADIS16135
ALARMS
The alarm function provides monitoring for two independent
conditions. Table 22 contains a list of registers that provide
configuration and control inputs for the alarm function.
Table 26. ALM_CTRL Bit Descriptions
Bits
[15:12]
Table 22. Registers for Alarm Configuration
Register
ALM_MAG1
ALM_MAG2
ALM_SMPL1
ALM_SMPL2
ALM_CTRL
Address
0x10
0X12
0x14
0x16
0x18
Description
Alarm 1, trigger setting
Alarm 2, trigger setting
Alarm 1, sample period
Alarm 2, sample period
Alarm configuration
[11:8]
[7]
The ALM_CTRL register (see Table 26) provides data source
selection (Bits[15:8]), static/dynamic setting for each alarm
(Bits[7:6]), trigger polarity (Bits[5:4]), data source filtering
(Bit 3), and an alarm indicator signal (Bits[2:0]).
Static Alarm Use
The static alarms setting compares the data source selection
(ALM_CTRL[15:8]) with the values in the ALM_MAGx
registers in Table 23 and Table 24. The data format in these
registers matches the format of the data selection in
ALM_CTRL[15:8]. ALM_CTRL[5:4] provide polarity settings.
See Table 27 for a static alarm configuration example.
Table 23. ALM_MAG1 Bit Descriptions
Bits
[15:0]
[5]
[4]
[3]
[2]
[1]
[0]
1
Description (Default = 0x0000)
Threshold setting; matches format of the
ALM_CTRL[11:8] selection
Filtering applies to GYRO_OUT only.
Alarm Example
Table 24. ALM_MAG2 Bit Descriptions
Bits
[15:0]
[6]
Description (Default = 0x0000)
Threshold setting; matches for format of the
ALM_CTRL[15:12] selection
Dynamic Alarm Use
The dynamic alarm setting monitors the data selection for a
rate-of-change comparison. The rate of change is represented
by the magnitude in the ALM_MAGx registers over the time
represented by the number of samples setting in the ALM_SMPLx
register (see Table 25). See Table 27 for a dynamic alarm
configuration example.
Table 27 offers an example that configures Alarm 1 to trigger
when filtered GYRO_OUT data drops below 50°/sec and Alarm 2
to trigger when filtered GYRO_OUT data changes by more
than 50°/sec over a 100 ms period, or 5000°/sec2. The filter
setting helps reduce false triggers from noise and refine the
accuracy of the trigger points. The ALM_SMPL2 setting of 102
samples provides a comparison period that is 99.6 ms for an
internal sample rate of 1024 SPS. There is no need to program
ALM_SMPL1 because Alarm 1 is a static alarm in this example.
Table 27. Alarm Configuration Example 1
DIN
0x9911,
0x98AF
Table 25. ALM_SMPL1, ALM_SMPL2 Bit Descriptions
Bits
[15:8]
[7:0]
Description (Default = 0x0000)
Not used
Binary, number of samples (both 0x00 and 0x01 = 1)
Alarm Reporting
DIAG_STAT[9:8] provide error flags that indicate an alarm
condition. ALM_CTRL[2:0] provide controls for a hardware
indicator using DIO1 or DIO2.
Description (Default = 0x0000)
Alarm 2 source selection
0000 = disable
0001 = GYRO_OUT (does not include GYRO_OUT2)
0010 = TEMP_OUT
0011 = DIAG_STAT
Alarm 1 source selection (same as Alarm 2)
Rate-of-change enable for Alarm 2
(1 = rate of change, 0 = static level)
Rate-of-change enable for Alarm 1
(1 = rate of change, 0 = static level)
Comparison polarity for Alarm 2
(1 specifies >ALM_MAG2, 0 specifies <ALM_MAG2)
Comparison polarity for Alarm 1
(1 specifies >ALM_MAG1, 0 specifies <ALM_MAG1)
Comparison data filter setting1
(1 = Bartlett filter, 0 = no filtering)
Alarm output enable
(1 = enabled, 0 = disabled)
Alarm output polarity
(1 = active high, 0 = active low)
Alarm output line select
(1 = DIO2, 0 = DIO1)
0x930F,
0x92A0
Description
ALM_CTRL = 0x11AF
Alarm 2: dynamic; Δ-GYRO_OUT
(Δ-time, ALM_ SMPL2) > ALM_MAG2
Alarm 1: static; GYRO_OUT < ALM_MAG1
use filtered data source for comparison
DIO2 output indicator, positive polarity
ALM_MAG2 = 0x0FA0, (+50°/sec)
0x910F,
0x90A0
ALM_MAG1 = 0x0FA0, (+50°/sec)
0x9666
ALM_SMPL2[7:0] = 0x66 (102 samples)
Rev. 0 | Page 13 of 20
ADIS16135
SYSTEM CONTROLS
The ADIS16135 provides a number of system-level controls for
managing its operation using the registers listed in Table 28.
600
Address
0x1A
0x1C
0x24
0x26
0x28
0x32
0x34
0x36
0x38
0x3A
Description
General-purpose I/O control
Self-test, calibration, data ready
Sleep mode control
Error flags
Single-command functions
Lot Identification Code 1
Lot Identification Code 2
Lot Identification Code 3
Product identification
Serial number
450
300
150
0
30
40
55
70
85
100
125
JUNCTION TEMPERATURE (°C)
135
150
08888-113
Register Name
GPIO_CTRL
MSC_CTRL
SLP_CTRL
DIAG_STAT
GLOB_CMD
LOT_ID1
LOT_ID2
LOT_ID3
PROD_ID
SERIAL_NUM
RETENTION (Years)
Table 28. System Tool Registers
Figure 20. Flash Memory Retention
GLOBAL COMMANDS
Checksum Test
The GLOB_CMD register (see Table 29) provides trigger bits
for several operations. Write 1 to the appropriate bit in GLOB_
CMD to start a function. After the function completes, the bit
restores to 0.
Set MSC_CTRL[11] = 1 (DIN = 0x9D08) to perform a checksum verification of the internal program memory. This takes a
summation of the internal program memory and compares it
with the original summation value for the same locations (from
factory configuration). Check the results in the DIAG_STAT
register (see Table 34). DIAG_STAT[6] = 0 if the sum matches
the correct value and 1 if it does not. Make sure that the power
supply is within specification for the entire 20 ms that this
function takes to complete.
Software Reset
Set GLOB_CMD[7] = 1 (DIN = 0xA880) to reset the operation,
which removes all data, initializes all registers from their flash
settings, and starts data collection. This function provides a
firmware alternative to the RST line (see Table 5, Pin 8).
Table 29. GLOB_CMD Bit Descriptions
Bits
[15:8]
[7]
[6:4]
[3]
[2]
[1]
[0]
1
Description (Default = 0x0000)
Not used
Software reset
Not used
Flash update
Not used
Factory calibration restore
Automatic bias correction
Execution Time
N/A
74 ms
N/A
72 ms
N/A
71 ms
N/A1
Execution time is based on SMPL_PRD and DEC_RATE settings. This starts at
the next data ready pulse, restarts the decimation cycle, and then writes to
the flash (72 ms) after completing a decimation cycle. With respect to Figure
18, the decimation cycle time = ND ÷ FS.
MEMORY MANAGEMENT
The flash memory’s data retention has a dependency on
temperature, as shown in Figure 20. The FLASH_CNT register
(see Table 30) provides a 16-bit counter that helps track the
number of write cycles to the nonvolatile flash memory, which
helps the user manage against the endurance rating. The flash
updates every time any of the following bits are set to 1:
GLOB_CMD[3], GLOB_CMD[1], and GLOB_ CMD[0].
GENERAL-PURPOSE I/O
There are two general-purpose I/O lines, DIO1 and DIO2,
which provide a number of useful functions. The
MSC_CTRL[2:0] bits (see Table 31) control the data-ready
configuration and have the highest priority for setting either
DIO1 or DIO2 (but not both). The ALM_CTRL[2:0] control
bits (see Table 26) provide the alarm indicator configuration
control and have the second highest priority for DIO1 or DIO2.
When DIO1 and DIO2 are not in use as either data-ready or
alarm indicator signals, the GPIO_CTRL register (see Table 32)
provides the control and data bits for them.
Data Ready I/O Indicator
The factory default setting for MSC_CTRL[2:0] is 110, which
configures DIO1 as a positive data-ready indicator signal. A
common option for this function is MSC_CTRL[2:0] = 100
(DIN = 0x9C04), which changes data ready to a negative
polarity for processors that provide only negative-triggered
interrupt pins. The pulse width is between 100 μs and 200 μs
over all conditions.
Table 30. FLASH_CNT Bit Descriptions
Bits
[15:0]
Description)
Binary counter; number of flash updates
Rev. 0 | Page 14 of 20
ADIS16135
Example I/O Configuration
POWER MANAGEMENT
For example, set GPIO_CTRL[7:0] = 0x02 (DIN = 0x9A02) to
set DIO1 as an input and DIO2 as an output. Then, set
GPIO_CTRL[15:8] = 0x02 (DIN = 0x9B02) to set DIO2 in a
high output state. Monitor DIO1 by reading GPIO_CTRL[8]
(DIN = 0x1B00).
The SLP_CTRL register (see Table 33) provides two different
sleep modes for system-level management: normal and timed.
Set SLP_CTRL[7:0] = 0xFF (DIN = 0xA4FF) to start normal
sleep mode. To awaken the device from sleep mode, use one of
the following options to restore normal operation: assert CS
from high to low, pulse RST low, then high again, or cycle the
power. Use SLP_CTRL[7:0] to put the device into sleep mode
for a specified period. For example, SLP_CTRL[7:0] = 0x64
(DIN = 0xA464) puts the ADIS16135 to sleep for 50 sec.
Table 31. MSC_CTRL Bit Descriptions
Bits
[15:12]
[11]
[10]
[9]
[8]
[7]
[6:3]
[2]
[1]
[0]
Description (Default = 0x0006)
Not used
Memory test (cleared upon completion)
(1 = enabled, 0 = disabled)
Automatic self-test (cleared upon completion)
(1 = enabled, 0 = disabled)
Manual self-test
(1 = enabled, 0 = disabled)
Not used
Disable sensor compensation
(1 = disable compensation, 0 = enable compensation)
Not used
Data-ready enable
(1 = enabled, 0 = disabled)
Data-ready polarity
(1 = active high, 0 = active low)
Data-ready line select
(1 = DIO2, 0 = DIO1)
Table 32. GPIO_CTRL Bit Descriptions
Bits
[15:10]
[9]
[8]
[7:2]
[1]
[0]
Description (Default = 0x0000)
Don’t care
General-Purpose I/O Line 2 (DIO2) data level
General-Purpose I/O Line 1 (DIO1) data level
Don’t care
General-Purpose I/O Line 2 (DIO2) direction control
(1 = output, 0 = input)
General-Purpose I/O Line 1 (DIO1) direction control
(1 = output, 0 = input)
SELF-TEST
The MSC_CTRL bits (see Table 31) provide a self-test function,
which helps verify the mechanical integrity of the MEMS and
signal processing circuit. When enabled, the self-test applies an
electrostatic force to the internal sensor element, which causes it
to move in a manner that simulates its response to actual
rotation. There are two self-test options in the MSC_CTRL
register: automatic and manual. Set MSC_CTRL[10] = 1 (DIN
= 0x9D04) to run the automatic self-test routine, which reports
a pass/fail result in DIAG_STAT[5]. MSC_CTRL[10] resets
itself to 0 after completing this routine. This process takes
approximately 46 ms. Set MSC_CTRL[9] = 1 (DIN = 9D01) to
manually activate the self-test function, and set MSC_CTRL[9]
= 0 (DIN = 9D00) to manually deactivate the self-test function.
Measure the output bias for each condition, take the difference
between them, and compare it to the expected self-test response
shown in Table 1.
Table 33. SLP_CTRL Bit Descriptions
Bits
[15:8]
[7:0]
Description
Not used
0xFF: normal sleep mode
0x00 to 0xFE: programmable sleep time bits; 0.5 sec/LSB
STATUS
The DIAG_STAT register (see Table 34) provides error flags for
a number of functions. Each flag uses a 1 to indicate an error
condition and a 0 to indicate a normal condition. Reading this
register provides access to each flag’s status and resets all of the
bits to 0 for monitoring future operation. If the error condition
remains, the error flag returns to 1 at the conclusion of the next
sample cycle. DIAG_STAT[0] does not require a read of this
register to return to 0. If the power supply voltage goes back
into range, this flag clears automatically. The SPI communication
error flag in DIAG_STAT[3] indicates that the number of
SCLKs in a SPI sequence did not equal a multiple of 16 SCLKs.
Table 34. DIAG_STAT Bit Descriptions
Bits
[15:10]
[9]
[8]
[7]
[6]
[5]
[4]
[3]
[2]
[1]
[0]
Rev. 0 | Page 15 of 20
Description (Default = 0x0000)
Not used
Alarm 2 status (1 = active, 0 = inactive)
Alarm 1 status (1 = active, 0 = inactive)
Not used
Flash test, checksum flag (1 = fail, 0 = pass)
Self-test diagnostic error flag (1 = fail, 0 = pass)
Sensor over range (1 = over range, 0 = normal)
SPI communication failure (1 = fail, 0 = pass)
Flash update failure (1 = fail, 0 = pass)
Not used
Power supply low, (1 = VCC <4.75 V, 0 = VCC >4.75 V)
ADIS16135
PRODUCT IDENTIFICATION
Table 36. SERIAL_NUM Bit Descriptions
The PROD_ID register (see Table 37) contains 0x3F07, which is
the hexadecimal equivalent of 16,135. The LOT_ID1, LOT_ID2,
and LOT_ID3 registers (see Table 35) provide manufacturing
lot information. The SERIAL_NUM register (see Table 36)
contains a binary number that represents the serial number on
the device label and is lot specific.
Bits
[15:14]
[13:0]
Table 37. PROD_ID Bit Descriptions
Bits
[15:0]
Table 35. LOT_ID1, LOT_ID2, LOT_ID3 Bit Descriptions
Bits
[15:0]
Description
Not used
Serial number, 1 to 9999 (0x270F)
Description
Lot identification, binary code
Rev. 0 | Page 16 of 20
Description
Product identification = 0x3F07
ADIS16135
APPLICATIONS INFORMATION
PROTOTYPE INTERFACE BOARD
INSTALLATION TIPS
The ADIS16135/PCBZ includes one ADIS16135BMLZ, one
interface PCB, and four M2x18 machine screws. The interface
PCB provides larger connectors than the ADIS16135BMLZ for
simpler prototyping, four-tapped M2 holes for attachment of
the ADIS16135BMLZ, and four holes (machine screw size M2.5
or #4) for mounting the ADIS16135BMLZ to a solid structure.
J1 and J2 are dual-row, 2 mm (pitch) connectors that work with
a number of ribbon cable systems, including 3M Part Number
152212-0100-GB (ribbon crimp connector) and 3M Part Number
3625/12 (ribbon cable).
Figure 23 and Figure 24 provide the mechanical design
information used for the ADIS16135/PCBZ. Use these figures
when implementing a connector-down approach, where the
mating connector and the ADIS16135BMLZ are on the same
surface. When designing a connector-up system, use the
mounting holes shown in Figure 23 as a guide in designing the
bulkhead mounting system and use Figure 24 as a guide in
developing the mating connector interface on a flexible circuit or
other connector system.
Figure 21 provides the top-level view of the interface board.
Install the ADIS16135BMLZ onto this board using the silk
pattern as an orientation guide. Figure 22 provides the pin
assignments for J1 and J2. The pin descriptions match those
listed in Table 5. The ADIS16135 does not require external
capacitors for normal operation; therefore, the interface PCB
does not use the C1/C2 pads.
31.200 BSC
15.600 BSC
2x 0.560 BSC
ALIGNMENT HOLES
FOR MATING SOCKET
39.60 BSC
19.800 BSC
17.520
2.280
4x 2.500 BSC
08888-022
iSensor
5.00 BSC
5.00 BSC
Figure 23. Suggested Mounting Hole Locations, Connector Down
0.4334 [11.0]
0.019685
[0.5000]
(TYP)
0.0240 [0.610]
0.054 [1.37]
Figure 21. Physical Diagram for the ADIS16135/PCBZ
0.022±
DIA (TYP)
0.022 DIA THRU HOLE (TYP)
NONPLATED
NONPLATED THRU HOLE
THRU HOLE 2×
Figure 24. Suggested Layout and Mechanical Design for the Mating Connector
RST
1
2
SCLK
DNC
1
2
GND
CS
3
4
DOUT
DNC
3
4
DNC
DNC
5
6
DIN
GND
5
6
CLKIN
GND
7
8
GND
DNC
7
8
DNC
GND
9
10
VCC
DNC
9
10
DNC
VCC
11
12
VCC
DIO2
11
12
DIO1
08888-021
J2
J1
0.0394 [1.00]
08888-023
08888-020
0.0394 [1.00] 0.1800
[4.57]
Figure 22. J1/J2 Pin Assignments
Rev. 0 | Page 17 of 20
ADIS16135
OUTLINE DIMENSIONS
35.854
35.600
35.346
31.350
31.200
31.050
15.700
15.600
15.500
2.200
TYP
2.400 THRU HOLE
(4 PLACES)
44.254
44.000
43.746
17.670
17.520
17.370
39.750
39.600
39.450
19.900
19.800
19.700
TOP VIEW
14.054
13.800
13.546
2.200 TYP
END VIEW
3.27
3.07
2.87
0.30 BSC SQ
(PIN SIZE)
010908-A
1.00 BSC
(LEAD PITCH)
5.50 BSC
Figure 25. 24-Lead Module with Connector Interface
(ML-24-3)
Dimensions shown in millimeters
ORDERING GUIDE
Model1
ADIS16135BMLZ
ADIS16135/PCBZ
1
Temperature Range
−40°C to +105°C
Package Description
24-Lead Module with Connector Interface
Interface PCB
Z = RoHS Compliant Part.
Rev. 0 | Page 18 of 20
Package Option
ML-24-3
ADIS16135
NOTES
Rev. 0 | Page 19 of 20
ADIS16135
NOTES
©2010 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective owners.
D08888-0-4/10(0)