LAMBDA DSR180-48-24 Single output 30w~180w Datasheet

DSR-SERIES
Single output 30W ~ 180W
Unit Type Power Supply
䡵 Model name
DSR 50-5-24
Output voltage: 5 ~ 48V
Name of series
Output power: 30W, 50W, 180W
Input voltage
24: 18 ~ 32VDC
48: 32 ~ 63VDC
䡵 Features
䢇 Long life and high reliability
Over 10 years lifetime at 40°C, full load
Vibration: 5G max.
䢇 Wide operating temperature range: –20 ~ +71°C
䢇 Input voltage range
DC24V input: DC18 ~ 32V, 48V input: 32 ~ 63V
䢇 Wide variation
DC24V input: 17 models, 30/50/180W
DC48V input: 12 models, 30/50W
䢇 5 year warranty
DSR50 (DC48V INPUT)
DSR30 (DC48V INPUT)
DSR50 (DC24V INPUT)
DSR30 (DC24V INPUT)
DSR180 (DC24V INPUT)
5 year warranty
䡵 Specifications
1. Input voltage range
2. Output voltage
range
3. Line regulation
4. Load regulation
5. Cooling
6. Operating ambient
temperature
(Standard mounting)
7. Withstand voltage
8. Vibration
9. Functions
DC 24V input: DC 18 ~ 32V
DC 48V input: DC 32 ~ 63V
–10% ~ +20%
0.4% (DC18 ~ 32V/DC32 ~ 63V, at constant load)
0.8% (No load – full load, at constant input voltage)
Convection cooling
–20 ~ +71°C (+61 ~ +70°C: Forced Air Cooling)
–20°C: 50%, 0 ~ +50°C: 100%, +60°C: 70%, +71°C: 50%
Input–output: 1.5kVAC, input–FG: 1.5kVAC, output–FG: 500VAC for 1 min.
(DSR180... Input/output–FG: 2.5kVAC, output–FG: 500VAC for 1 min.)
When not operating 10 ~ 55Hz, amplitude 0.825mm constant (MAX. 5G), Sweep for 1 min., X, Y and Z axes for 1 hour
Over voltage protection, Over current protection, Thermal protection, Remote on/off control
Low input protection, Power failure (Low output voltage detection signal)
DSRI80: Remote sensing, Output current balancing, Switching frequency synchronization
Output voltage programmable by external control
䡵 Product lineup
Model name
DSR30
DSR30-5-24
DSR30-12-24
DSR30-15-24
DSR30-24-24
DSR30-40-24
DSR30-48-24
DSR30-5-48
DSR30-12-48
DSR30-15-48
DSR30-24-48
DSR30-40-48
DSR30-48-48
Nominal
Max.
Max.
output voltage output current output power
30.0W
5V
6.0A
30.0W
12V
2.5A
30.0W
15V
2.0A
31.2W
24V
1.3A
32.0W
40V
0.8A
33.6W
48V
0.7A
30.0W
5V
6.0A
30.0W
2.5A
12V
30.0W
2.0A
15V
31.2W
1.3A
24V
32.0W
0.8A
40V
33.6W
0.7A
48V
UL
CSA
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
Model name
DSR50
DSR180
䢇 Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
䢇 Contact us about delivery before ordering.
46
DSR50-5-24
DSR50-12-24
DSR50-15-24
DSR50-24-24
DSR50-40-24
DSR50-48-24
DSR50-5-48
DSR50-12-48
DSR50-15-48
DSR50-24-48
DSR50-40-48
DSR50-48-48
DSR180-5-24
DSR180-6-24
DSR180-12-14
DSR180-24-24
DSR180-48-24
Nominal
Max.
Max.
output voltage output current output power
5V
50.0W
10.0A
12V
51.6W
4.3A
15V
51.0W
3.4A
24V
50.4W
2.1A
40V
52.0W
1.3A
48V
52.8W
1.1A
5V
50.0W
10.0A
12V
51.6W
4.3A
15V
51.0W
3.4A
24V
50.4W
2.1A
40V
52.0W
1.3A
48V
52.8W
1.1A
5V
180W
36A
6V
180W
30A
12V
180W
15A
24V
180W
7.5A
48V
177.6W
3.7A
UL
CSA
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆ : Conforms to safety standard
DSR-SERIES
Unit Type Power Supply
䡵 DSR30
(FRONT VIEW)
(LEFT SIDE VIEW)
(BOTTOM VIEW)
䢇Recommended Noise Filter
MAW-1203-22
GO!!
P134
(Unit: mm)
䡵 DSR50
(FRONT VIEW)
(LEFT SIDE VIEW)
4-M3 MOUNTING HOLES
(DEPTH 6mm MAX)
TERMINAL COVER
(BOTTOM VIEW)
2-R1.75
MOUNTING
䢇Recommended Noise Filter
MAW-1205-22
3-M3 MOUNTING HOLES
(DEPTH 6mm MAX)
GO!!
P134
ø3.5 MOUNTING HOLE
(Unit: mm)
䡵 DSR180
(FRONT VIEW)
(LEFT SIDE VIEW)
(BOTTOM VIEW)
䢇Recommended Noise Filter
MB1220
GO!!
P137
(Unit: mm)
47
DSR (Input : 110VDC)-SERIES
Single output 20W ~ 35W
Unit Type Power Supply
䡵 Model name
DSR 35-5-110
Nominal output voltage: 2 ~ 48V
Name of series
Input voltage
110: 70 ~143VDC
Output power: 20W, 35W
䡵 Features
䢇 110VDC input, Single output
䢇 Long life and high reliability
Over 10 years lifetime at 40°C, full load
Vibration: 5G max.
䢇 Wide operating temperature range: –20 ~ +71°C
䢇 Low input surge current 3.7A
DSR35 (DC110V INPUT)
DSR20 (DC110V INPUT)
5 year warranty
䡵 Specifications
1. Input voltage range
2. Output voltage range
3. Line regulation
4. Load regulation
5. Cooling
DC 70 ~ 143V
Ⳳ10%
0.4% (DC18 ~ 32V/DC32 ~ 63V, at constant load/output 2V : 20mV)
0.4% (No load – full load, at constant input voltage/output 2V : 20mV)
Convection cooling
6. Operating ambient
temperature
(Standard mounting)
–20 ~ +71°C
7. Withstand voltage
8. Vibration
Input–output: 2.5kVAC, input–FG: 2.5kVAC for 1 min.(20mA), Output–FG: 500VAC for 1 min.(100mA)
When not operating 10 ~ 55Hz, amplitude 0.825mm constant (MAX. 5G), Sweep for 1 min., X, Y and Z axes for 1 hour
9. Functions
Over voltage protection, Over current protection, Thermal protection, Remote on/off control
Low input protection, Power failure (Low output voltage detection signal)
䡵 Product lineup
Model name
DSR20
DSR35
DSR20-2-110
DSR20-5-110
DSR20-6-110
DSR20-12-110
DSR20-15-110
DSR20-24-110
DSR20-40-110
DSR20-48-110
DSR35-2-110
DSR35-5-110
DSR35-6-110
DSR35-12-110
DSR35-15-110
DSR35-24-110
DSR35-40-110
DSR35-48-110
Nominal
output voltage
2V
5V
6V
12V
15V
24V
40V
48V
2V
5V
6V
12V
15V
24V
40V
48V
䢇 Request customer specification for further details of specifications, outline, characteristics, etc.
Read the instruction manual before usage.
䢇 Contact us about delivery before ordering.
48
Max.
output current
4.0A
4.0A
3.3A
1.7A
1.4A
0.9A
0.5A
0.4A
7.0A
7.0A
6.0A
3.0A
2.6A
1.8A
1.0A
0.9A
Max.
output power
8.0W
20.0W
19.8W
20.4W
21.0W
21.6W
20.0W
19.2W
14.0W
35.0W
36.0W
36.0W
39.0W
43.2W
40.0W
43.2W
UL
CSA
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆
∆ : Conforms to safety standard
DSR-SERIES
Unit Type Power Supply
䡵 DSR20 (Input:110VDC)
TERMINAL COVER
2-M3 MOUNTING HOLE
DEPTH 6mm MAX
䢇Recommended Noise Filter
MAW-12R5-22
GO!!
P134
(Unit: mm)
䡵 DSR35 (Input:110VDC)
TERMINAL COVER
2-M3 MOUNTING HOLE
DEPTH 6mm MAX
䢇Recommended Noise Filter
MAW-1201-22
GO!!
P134
(Unit: mm)
49