NEC EE2-5SNUH-L6 Compact and lightweight, high breakdown voltage, surface mounting type Datasheet

DATA SHEET
MINIATURE SIGNAL RELAY
EE2 SERIES
Compact and lightweight, High breakdown voltage,
Surface mounting type
DESCRIPTION
The EE2 series surface-mounting type sustaining high-performance of NEC TOKIN EC2 series.
FEATURES
Compact and light weight
2 form c contact arrangement
Low power consumption
Reduced mounting space : 15 mm × 9.5 mm
High-breakdown voltage of coil to contacts : 1500 Vac, 2500 V
(rise time : 2 µs, fall time : 10 µs)
Low power consumption : 100 to 140 mW
Capable of High-power switching : 700 Vac, 4.2 A, 4 times in case of accident
NK type guarantee 1.5kVac over withstanding voltage at open contact. (Only make contact)
APPLICATIONS
Electronic switching systems, PBX, terminal equipment, telephone system.
For Right Use of Miniature Relays
DO NOT EXCEED MAXIMUM RATINGS.
Do not use relays under exceeding conditions such as over ambient temperature, over voltage and over
current. Incorrect use could result in abnormal heating, damage to related parts or cause burning.
READ CAUTIONS IN THE SELECTION GUIDE.
Read the cautions described in NEC/TOKIN's "Miniature Relays" when you choose relays for your application.
Document No. 0606EMDD03VOL02E
Date Published May 2005 P
Printed in Japan
© NEC TOKIN Corporation 2002
EE2 SERIES
PART NUMBER SYSTEM
OUTLINE DRAWINGS AND DIMENSIONS
,..NKX
2
EE2 SERIES
PAD LAYOUTS (bottom view)
PIN CONFIGURATIONS (bottom view)
MARKINGS (top view)
SAFETY STANDARD AND RATING
UL Recognized
CSA Certificated
(UL508)*
(CSA C22.2 No14)
File No E73266
File No LR46266
30 Vdc, 2 A (Resistive)
110 Vdc, 0.3 A (Resistive)
125 Vac, 0.5 A (Resistive)
* Spacing : UL114, UL478
TUV Certificate
(EN60255 / IEC60255)
No. R 9751153
(Nonlatch and Single-coil-latch)
Creepage and clearance of
coil to contact is more than 2 mm.
(According EN60950)
Basic insulation class
3
EE2 SERIES
PERFORMANCE CHARACTERISTICS
Contact Form
Contact Material
Contact Ratings
2 Form C
Silver alloy with gold alloy overlay
Maximum Switching Power 60 W, 125 VA
Maximum Switching Voltage 220 Vdc, 250 Vac
Maximum Switching Current 2 A
Maximum Carrying Current 2 A
Minimum Contact Ratings
Initial Contact Resistance
Nonlatch type
Nominal Operating Power
Single coil latch type
Single coil latch type
Operate Time (Excluding bounce)
Release Time (Excluding bounce)
Insulation Resistance
Between open Contacts
Withstanding
Between Adjacent Contacts
Between Coil to Contact
Shock Resistance
Vibration Resistance
Ambient Temperature
Coil Temperature Rise
Nonload
Running specifications
Load
Weight
*1
*2
*3
*4
10 mVdc, 10 µA *1
75 mΩ max. (Initial)
140 mW (3 to 12 V), 200 mW (24 V)
(ND type : 200 to 230 mW)
(NK type : 230 mW)
100 mW (ND type : 100 to 170 mW)
140 mW
Approx. 2 ms
Approx. 1 ms
1000 MΩ at 500 Vdc
1000 Vac (for one minute) 1500 V surge (10 × 160 µs *2)
NK type :
Make contact : 1500 Vac (for one minute) 2500 V surge (2 × 10 µs*3)
Break contact : 1000 Vac (for one minute) 1500 V surge (10 × 160 µs *2)
1000 Vac (for one minute), 1500 V surge (10 × 160 µs *2)
1500 Vac (for one minute), 2500 V surge, (2 × 10 µs *3)
2
735 m / s (75G)(misoperating)
2
980 m / s (100G)(destructive failure)
10 to 55 Hz double amplitude 3 mm (misoperation)
10 to 55 Hz, double amplitude 5 mm (destructive failure)
‐40 to 85°C
18 degrees at nominal coil voltage (140 mW)
8
7
1 × 10 *4 operations (Nonlatch type) 1 × 10 operations (latch type)
6
50 Vdc 0.1 A (resistive), 1 × 10 operations at 85°C, 5 Hz
6
10 Vdc 10 mA (resistive), 1 × 10 operations at 85°C, 2 Hz
Approx. 1.9 g
This value is a reference value in the resistance load.
Minimum capacity changes depending on seitching frequency and environment temperature and the load.
rise time : 10 µs, decay time to half crest : 160 µs
rise time : 2 µs, decay time to half crest : 10 µs
This shows a number of operation where it can be running by which a fatal defect is not caused, and a number of
7
operation by which a steady characteristic is maintained is 1 × 10 operations.
Recommended relay drive conditions
Drive under conditions. If it is impossible, please inquire to NEC/TOKIN.
Nonlatch type
Voltage: within ±5% at nominal voltage
Ambient temperature
Square pulse (rise and fall time is rapidly)
Single coil latch type
‐40 to +85°C
Pulse height : within ±5% at nominal voltage
Double coil latch type
Pulse width : More than 10 ms
4
EE2 SERIES
PRODUCT LINEUP
at 20°C
Non-latch Type
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Coil
Resistance
(Ω) ±10 %
64.3
145
178
257
579
1028
2880
Must Operate
Voltage
(Vdc)
2.25
3.38
3.75
4.5
6.75
9
18
Must Release
Voltage
(Vdc)
0.3
0.45
0.5
0.6
0.9
1.2
2.4
Coil
Resistance
(Ω) ±10 %
90
202.5
250
360
810
1440
5760
Must Operate
Voltage
(Vdc)
2.25
3.38
3.75
4.5
6.75
9
18
Must Release
Voltage
(Vdc)
2.25
3.38
3.75
4.5
6.75
9
18
at 20°C
Single-Coil Latch Type
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Double-Coil Latch Type
**
(Can not be driven by revese polarity for reverse operation.)
Nominal Coil
Voltage
(Vdc)
3
4.5
5
6
9
12
24
Coil
Resistance
(Ω) ±10 %
S
R
S
R
S
R
S
R
S
R
S
R
S
R
64.3
64.3
145
145
178
178
257
257
579
579
1028
1028
4114
4114
Must Operate
Voltage
(Vdc)
2.25
‐
3.38
‐
3.75
‐
4.5
‐
6.75
‐
9
‐
18
‐
at 20°C
Must Release
Voltage
(Vdc)
‐
2.25
‐
3.38
‐
3.75
‐
4.5
‐
6.75
‐
9
‐
18
Note * Test by pulse voltage
** S : Set coil (pin No.1... ○
+ , pin No.5... ○
- ) R : Reset coil (pin No.10... ○
+ , pin No.6... ○
- )
The latch type relays should be initalized at appointed position before using, and should be enegized to specific polanity
by a bone polabity to avoid wrong operation.
Any special coil requirement, please contact NEC/TOKIN for availability.
at 20°C
Nonlatch NKX type (High voltage, high solder joint reliabillity type)
Nominal
Coil Voltage
(Vdc)
3
4.5
12
Coil
Resistance
(Ω) ±10 %
39.1
88.0
626
Must Operate
Voltage *
(Vdc)
2.25
3.38
9.0
Must Release
Voltage *
(Vdc)
0.3
0.45
1.2
5
EE2 SERIES
PERFORMANCE DATA
■COIL TEMPERATURE RISE
Temperature is measured by coil resistance.
■SWITCHING CAPACITY
This is allowed maximum value.
Inquiry for NEC/TOKIN under maximum value at
continuous use.
■MAXIMUM COIL VOLTAGE
This is maximum value of permissible alteration.
Inquiry for NEC/TOKIN at continuous use.
■APPLIED VOLTAGE VS. TIMING (Sample: EE2-5NU)
6
EE2 SERIES
■OPERATE AND RELEASE VOLTAGE VS. AMBIENT TEMPERATURE
This shows a typical change of operate (release) voltage. Maximum value of operate estimated, so it must be
applied more than this value for safety operation. In case of “hot start operation”, please inquiry for NEC/TOKIN.
■RUNNING TEST (Nonload)
(Load: None, Driving: 5V.DC, 50 Hz, 50% duty, Ambient temperature: Room temperature, Sample: EE2-5NU 20 pieces)
■RUNNING TEST (Load)
(Load: 50 V.DC 0.1 A resistive, Driving: 5V.DC, 5 Hz, 50% duty, Ambient temperature: 85 degree C, Sample: EE2-5NU
10 pieces)
7
EE2 SERIES
■BREAKDOWN VOLTAGE
Sample: EE2-5NU 10 pieces
■ALTERNATION OF VOLTAGE AT DENSELY MOUNTING (Magnet interference)
8
EE2 SERIES
SOLDERING CONDITION
Note:
1. Temperature profile shows printed circuit board surface temperature on the relay terminal portion.
2. Check the actual soldering condition to use other method except above mentioned temperature profiles.
9
EE2 SERIES
TUBE PACKAGE
Dimension of Package (Unit : mm)
Outline of Package
TAPE PACKAGE
APPEARANCE
TAPE DIMENSIONS Unit : mm (inch)
Relay orientation mark and tape carrying direction.
10
EE2 SERIES
Notes on Correct Use
1. Notes on contact load
Make sure that the contact load is within the specified range;
otherwise, the lifetime of the contacts will be shortened considerably.
Note that the running performance shown is an example, and that it
varies depending on parameters such as the type of load, switching
frequency, driver circuit, and ambient temperature under the actual
operating conditions. Evaluate the performance by using the actual
circuit before using the relay.
2. Driving relays
- If the internal connection diagram of a relay shows + and - symbols
on the coil, apply the rated voltage to the relay in the specified
direction. If a rippled DC current source is used, abnormalities such
as beat at the coil may occur.
- The maximum voltage that can be applied to the coil of the relay
varies depending on the ambient temperature. Generally, the higher
the voltage applied to the coil, the shorter the operating time. Note,
however, that a high voltage also increases the bounce of the
contacts and the contact opening and closing frequency, which may
shorten the lifetime of the contacts.
- If the driving voltage waveform of the relay coil rises and falls
gradually, the inherent performance of the relay may not be fully
realized. Make sure that the voltage waveform instantaneously rises
and falls as a pulse.
- For a latching relay, apply a voltage to the coil according to the
polarity specified in the internal connection diagram of the relay.
- If a current is applied to the coil over a long period of time, the coil
temperature rises, promoting generation of organic gas inside the
relay, which may result in faulty contacts. In this case, use of a
latching relay is recommended.
- The operating time and release time indicate the time required for
each contact to close after the voltage has been applied to or
removed from the coil. However, because the relay has a
mechanical structure, a bounce state exists at the end of the
operating and release times. Furthermore, because additional time
is required until the contact stabilizes after being in a high-resistance
state, care must be taken when using the relay at high speeds.
3. Operating environment
- Make sure that the relay mounted in the application set is used
within the specified temperature range. Use of a relay at a
temperature outside this range may adversely affect insulation or
contact performance.
- If the relay is used for a long period of time in highly humid (RH
85% or higher) environment, moisture may be absorbed into the
relay. This moisture may react with the NOx and SOx generated by
glow discharges that occur when the contacts are opened or closed,
producing nitric or sulfuric acid. If this happens, the acid produced
may corrode the metallic parts of the relay, causing operational
malfunction.
- Because the operating temperature range varies depending on the
humidity, use the relay in the temperature range illustrated in the
figure below. Prevent the relay from being frozen and avoid the
generation of condensation.
- The relay maintains constant sealability under normal atmospheric
pressure (810 to 1,200 hpa). Its sealability may be degraded or the
relay may be deformed and malfunction if it is used under barometric
conditions exceeding the specified range.
- The same applies when the relay is stored or transported. Keep the
upper-limit value of the temperature to which the relay is exposed
after it is removed from the carton box to within 50°C.
- If excessive vibration or shock is applied to the relay, it may
malfunction and the contacts remain closed. Vibration or shock
applied to the relay during operation may cause considerable
damage to or wearing of the contacts. Note that operation of a snap
switch mounted close to the relay or shock due to the operation of
magnetic solenoid may also cause malfunctioning.
4. Notes on mounting relays
- When mounting a relay onto a PC board using an automatic chip
mounter, if excessive force is applied to the cover of the relay when
the relay is chucked or inserted, the cover may be damaged or the
characteristics of the relay degraded. Keep the force applied to the
relay to within 1 kg.
- Avoid bending the pins to temporarily secure the relay to the PC
board. Bending the pins may degrade sealability or adversely affect
the internal mechanism.
- It is recommended to solder the relay onto a PC board under the
following conditions:
<1> Reflow soldering
Refer to the recommended soldering temperature profile.
<2> Flow soldering
Solder temperature: 260°C max., Time: 5 seconds max, Preheating:
100°C max./1 minute max.
<3> Manual soldering
Solder temperature: 350°C, Time: 2 to 3 seconds
- Ventilation immediately after soldering is recommended.
Avoid immersing the relay in cleaning solvent immediately after
soldering due to the danger of thermal shock being applied to the
relay.
- Use an alcohol-based or water-based cleaning solvent. Never use
thinner and benzene because they may damage the relay housing.
- Do not use ultrasonic cleaning because the vibration energy
generated by the ultrasonic waves may cause the contacts to
remain closed.
5. Handling
- Relays are packaged in magazine cases for shipment. If a space is
created in the case after some relays have been removed, be sure
to insert a stopper to secure the remaining relays in the case. If
relays are not well secured, vibration during transportation may
cause malfunctioning of the contacts.
- Exercise care in handling the relay so as to avoid dropping it or
allowing it to fall. Do not use a relay that has been dropped.
If a relay drops from a workbench to the floor, a shock of 9,800 m/s2
(1,000 G) or more is applied to the relay, possibly damaging its
functions. Even if a light shock has been applied to the relay,
thoroughly evaluate its operation before using it.
- Latching relays are factory-set to the reset state for shipment. A
latching relay may be set, however, by vibration or shock applied
while being transported. Be sure to forcibly reset the relay before
using it in the application set. Also note that the relay may be set by
unexpected vibration or shock when it is used in a portable set.
- The sealability of a surface-mount relay may be lost if the relay
absorbs moisture and is then heated during soldering. When storing
relays, therefore, observe the following points:
<1> Please use relays within 12 months after delivery. (Storage
conditions : 30 degrees C / 60% RH)
<2> For MBB packing, Please use relays within 2 years after
delivery.
(Stronge conditions : 30 degrees C / 60% RH)
After opening MBB packing, Please use within 3 months.
(Storage conditions : 30 degrees C/ 60% RH)
11
EE2 SERIES
No part of this document may be copied or reproduced in any form or by any means without the prior written
consent of NEC/TOKIN Corporation. NEC/TOKIN Corporation assumes no responsibility for any errors which
may appear in this document.
NEC/TOKIN Corporation does not assume any liability for infringement of patents, copyrights or other
intellectual property rights of third parties by or arising from use of a device described herein or any other liability
arising from use of such device. No license, either express, implied or otherwise, is granted under any patents,
copyrights or other intellectual property rights of NEC/TOKIN Corporation or others. While NEC/TOKIN
Corporation has been making continuous effort to enhance the reliability of its electronic components, the
possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property
arising from a defect in an NEC/TOKIN electronic component, customers must incorporate sufficient safety
measures in its design, such as redundancy, fire-containment, and anti-failure features. NEC/TOKIN devices
are classified into the following three quality grades:
"Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a
customer designated "quality assurance program" for a specific application. The recommended applications of a
device depend on its quality grade, as indicated below. Customers must check the quality grade of each device
before using it in a particular application.
Standard: Computers, office equipment, communications equipment, test and measurement equipment,
audio and visual equipment, home electronic appliances, machine tools, personal electronic
equipment and industrial robots
Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster
systems, anti-crime systems, safety equipment and medical equipment (not specifically designed
for life support)
Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life
support systems or medical equipment for life support, etc.
The quality grade of NEC/TOKIN devices is "Standard" unless otherwise specified in NEC/TOKIN's Data Sheets
or Data Books. If customers intend to use NEC/TOKIN devices for applications other than those specified for
Standard quality grade, they should contact an NEC/TOKIN sales representative in advance.
(Note)
(1) "NEC/TOKIN" as used in this statement means NEC/TOKIN Corporation and also includes its
majorityowned subsidiaries.
(2) "NEC/TOKIN electronic component products" means any electronic component product developed or
manufactured by or for NEC/TOKIN (as defined above).