MPD F2513RU 4:1 input 25w - 30w single & dual output dc/dc converter Datasheet

F2500RU Series
4:1 Input 25W - 30W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 25W-30W Output Power
• 4:1 Input Voltage Range
• 1,500 VDC Isolation
• Meets EN55022 Class A
• Compact 2 x 1.6 In. Case
• Single & Dual Outputs
• Remote ON/OFF
• Industry Standard Pin-Out
Input
Parameter
Input Start Voltage
Under Voltage Shutdown
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
Typ.
Max.
24 VDC Input
9.4
9.7
10.0
48 VDC Input 17.0
17.5
18.0
24 VDC Input
9.0
9.3
9.5
48 VDC Input 16.0
16.5
17.0
␲ (Pi) Filter (Meets EN55022 Class “A”)
2.0
4,500
Units
VDC
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
For Vin Min to Max
Iout = 50% to 100%
Typ.
±0.5
±0.5
±0.2
±0.3
55
Max.
±1.0
±2.0
±0.5
±1.0
80
100
180
300
±4.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
%
µSec
%
%/°C
Typ.
Max.
1,200
330
112
1,500
360
117
Units
VDC
VDC
M⍀
pF
kHz
°C
Over Line, Load & Temp.
120
150
±2.0
±0.01
Continuous (Autorecovery)
25% Load Step Change
General
Parameter
Isolation Voltage
Isolation Voltage Test
Isolation Resistance
Isolation Capacitance
Switching Frequency
Over Temperature Protection
Remote On/Off (Note 3)
Parameter
Supply On
Supply Off
Standby Input Current
Control Common
Conditions
60 Seconds
Flash Tested For 1 Second
500 VDC
100 kHz, 1V
Case Temperature
Conditions
Min.
1,500
1,650
1,000
290
107
Min.
2.5
-1.0
Typ.
Max.
Units
100.0
VDC
1.0
VDC
5
mA
Referenced to Negative Input (pin 2)
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
-40
-50
Free Air Convection
RH, Non-condensing
Ambient
Case
Max.
+50
+105
+125
Units
°C
°C
°C
95
%
2.0 x 1.6 x 0.37 Inches (50.8 x 40.6 x 9.3 mm)
Metal with Non-Conductive Base
1.75 Oz (48g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
260
5,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
F2501RU
F2502RU
F2503RU
F2504RU
F2505RU
F2506RU
F2511RU
F2512RU
F2513RU
F2514RU
F2515RU
F2516RU
Output
Over
Voltage Efficiency
Voltage Current
Current Protection
(%, Typ)
Nominal
Range Full-Load No-Load (VDC) (mA, Max) (mA, Min)
(VDC)
24
10.0 - 40.0
922
20
3.3
5,500
400.0
3.9
82
24
10.0 - 40.0
1,225
20
5.0
5,000
350.0
6.8
85
24
10.0 - 40.0
1,404
20
12.0
2,500
166.0
15.0
89
24
10.0 - 40.0
1,404
20
15.0
2,000
133.0
18.0
89
24
10.0 - 40.0
1,404
20
±12.0
±1,250
±83.0
±15.0
89
24
10.0 - 40.0
1,404
20
±15.0
±1,000
±65.0
±18.0
89
48
18.0 - 75.0
461
10
3.3
5,500
400.0
3.9
82
48
18.0 - 75.0
613
10
5.0
5,000
350.0
6.8
85
48
18.0 - 75.0
702
10
12.0
2,500
166.0
15.0
89
48
18.0 - 75.0
702
10
15.0
2,000
133.0
18.0
89
48
18.0 - 75.0
702
10
±12.0
±1,250
±83.0
±15.0
89
48
18.0 - 75.0
702
10
±15.0
±1,000
±65.0
±18.0
89
Voltage (VDC)
Current (mA)
Notes:
1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from
the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units.
For noise sensitive applications, the use of 4.7 µF capacitors will reduce the output ripple. The maximum
rms value of the output ripple is 10 mV.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. The maximum sink current at the on/off pin (pin 4) during a logic low is 100 µA. The maximum allowable
leakage current of a switch connected to the on/off pin (Pin 4) at logic high (2.5V to 100V) is 5 µA. If the on/
off pin (Pin 4) is left open, the unit operates. If it is grounded, the unit will shut off.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load
across the positive (+Vout) and negative (-Vout) outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input source with a highly inductive
impedance may affect the stability of the converter. In applications where the converter output loading is
high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to
insure start-up.
In this case, it is recommended that a low Equivalent Series Resistance (ESR <1.0⍀ at 100 kHz) capacitor
be mounted close to the converter. A 33 µF is recommended for 24V input models and a 10 µF for 48V units.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above
for the correct rating.
External Trim
A simple external circuit may be used to adjust
the converter output. To adjust the output DOWN,
connect a 5%, 3W resistor between the plus output
pin and the Vout trim pin. To adjust the output UP,
connect a 5%, 3W resistor between the minus
output pin and the Vout trim pin. To calculate the
correct resistor value use:
UP
Radj =
(33 x Vout) - (30 x Vadj)
Vadj - Vout
Down
Radj =
(36.667 x Vout) - (33 x Vout)
Vout - Vadj
For UP/Down trimming capability, connect a 10
kW potentiometer between the plus and minus
outputs with the wiper arm connected to the
Vout trim pin.
Capacitive
Load
(µF Max)
1,000
1,000
1,000
1,000
±330
±330
1,000
1,000
1,000
1,000
±330
±330
Fuse Rating
Slow-Blow
(mA)
5,000
5,000
5,000
5,000
5,000
5,000
3,000
3,000
3,000
3,000
3,000
3,000
For Heatsink Option, add suffix “H” to model number (i.e. F2503RU-H)
Mechanical Dimensions
Mechanical Notes:
Pin Connections
Pin Single
Dual
1
+Vin
+Vin
2
-Vin
-Vin
4 ON/OFF ON/OFF
5 No Pin +Vout
Pin Single
6
+Vout
7
-Vout
8
Trim
Dual
Comm.
-Vout
Trim
• All dimensions are typical
in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
Heatsink Dimensions (Optional)
Derating Curves
Heatsink Notes:
MicroPower Direct
• Use of the heatsink will extend the units operating temperature
range by approximately 10°C.
• The heatsink is black anodized aluminum.
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]
Similar pages