Hirose FH34SJ-4S-0.5SH50 0.5 mm pitch, 1.0 mm above the board top and bottom contact, back-flip actuator flexible printed circuit & flexible flat cable zif connector Datasheet

0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip
actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
FH34(S)Series
Increased FPC/FFC holding force
Space saving (30 pos. shown)
Actuator
Metal fittings
1.0mm
17m
m
3.2mm
Easy FPC/FFC insertion
Back opening rotating
17
mm
All four
sides are
chamfered.
Top contacts
FP
C
■Features
/F
FC
1. Low-profile
With the 1.0 mm above the board and width of 3.8 mm the
connectors are used in space saving applications.
Ready to insert FPC/FFC
2. Increased FPC/FFC retention
Delivered with
the actuator open
As compared with existing similar construction connectors:
* In horizontal direction: Approximately 2.6 times
* In vertical direction: Approximately 2 times
3. Unique Back-Flip rotating actuator
The rotating actuator opens from the back of the connector,
assuring reliable electrical and mechanical connection.
4. Easy FPC insertion and reliable electrical connection
Proven Flip Lock actuator allows easy insertion of FPC and
provides a tactile sensation when fully closed, confirming
complete electrical and mechanical connection.
5. Delivered with the actuator open
FPC/FPC can be immediately inserted without the need for the
opening of the actuator.
FPC
FPC/FFC inserted and retained.
Completed electrical and mechanical connection.
6. Accepts standard FPC thickness
0.3mm thick standard Flexible Printed Circuit (FPC) can be used.
This is the only ultra-low profile ZIF connector using standard
FPC.
7. Compatible with existing connectors.
FPC/FFC and PCB mounting patterns are the same as for the
FH19SC Series (bottom contact), allowing the use of both
connectors for interconnections between two boards or replacement
of the connectors.
8. Conductive traces on the PCB can run under
the connector
No exposed contacts on the bottom of the connector.
9. Board placement with automatic equipment
Flat upper surface and tape and reel packaging facilitate vacuum
pick-up and placement.
Standard reel packaging contains 5000 connectors.
Compatible with existing connectors.(FH19SC SERIES)
10.Halogen-free*
(FH34SJ,FH34SW,FH34SRJ)
*As defined by IEC61249-2-21
Br-900ppm maximum, Cl-900ppm maximum, Cl + Br combined-1,500ppm maximum
2012.3
1
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Specifications
Current rating 0.5 A (Note 1)
Ratings
Voltage rating 50 Vrms AC
Recommended FPC/FFC
Item
1. Insulation resistance
2. Withstanding voltage
3. Contact resistance
4. Durability
5. Vibration
6. Shock
7. Humidity (Steady state)
8. Temperature cycle
9. Resistance to soldering heat
Operating temperature range:
-55 to +85°C (Note 1)
Operating humidity range:
Relative humidity 90% max. (No condensation)
Storage temperature range:
-10 to +50°C (Note 2)
Storage humidity range:
Relative humidity 90% max. (No condensation)
Thickness: 0.3 ± 0.03 mm, Gold plated contact pads
Specification
500 Mø min.
No flashover or insulation breakdown
100 mø max.
* Including FPC and FFC conductor resistance
Contact resistance: 100 mø max.
No damage, cracks, or parts dislocation
No electrical discontinuity of 1µs or longer
Contact resistance: 100 mø max.
No damage, cracks, or parts dislocation
No electrical discontinuity of 1µs or longer
Contact resistance: 100 mø max.
No damage, cracks, or parts dislocation
Contact resistance: 100 mø max.
Insulation resistance: 50 Mø min.
No damage, cracks, or parts dislocation
Contact resistance: 100 mø max.
Insulation resistance: 50 Mø min.
No damage, cracks, or parts dislocation
No deformation of components affecting performance
Conditions
100 V DC
250 Vrms AC / one minute
1 mA, AC / DC 20mV max (AC: 1kHz)
20 cycles
Frequency: 10 to 55 Hz, single amplitude of 0.75
mm, 10 cycles in each of the 3 axis
Acceleration of 981m/s2, 6 ms duration, sine halfwave, 3 cycles in each of the 3 axis
96 hours at 40°C and humidity of 90 to 95%
Temperature : -55°C / +15°C to +35°C/+85°C / +15°C to +35°C
Time:
30 /
2 to 3
/ 30 / 2 to 3 minutes
5 cycles
Reflow: At the recommended temperature profile
Manual soldering: 350°C ±5°C for 5 seconds (Note 3)
Note1: When passing the current through all of the contacts, use 70% of the rated current.
Note2: Includes temperature rise caused by current flow.
Note3: The term "storage" refers to products stored for a long period prior to mounting and use.
The operating temperature and humidity range covers the non-conducting condition of installed connectors in storage, shipment or
during transportation after board mounting.
Note4: Information contained in this catalog represents general requirements for this Series.
Contact us for the drawings and specifications for a specific part number shown.
■Materials
Part
Material
Finish
FH34S series
Color:Beige
FH34SJ series
FH34SW series
FH34SR series
Color:Gray
FH34SRJ series
FH34S series
FH34SJ series
Color:Black
FH34SR series
FH34SRJ series
FH34SW series
Color:Light brown
FH34SJ series
Color:Black
FH34SR series
Gold plating with nickel barrier
Pure tin reflow plating
LCP
Insulator
PA
LCP(8pos.)
Contacts
Metalfittings
Phosphor bronze
Phosphor bronze
■Ordering information
FH 34S J - 30S - 0.5 SH (50)
1
2
3
1 Series name : FH
2 Series No.
: 34S
3 Blank : Standard
J
W
R
RJ
2
: Top contact, Halogen-free
(Flame retardance UL94V-0).
: Top contact, Halogen-free
(Flame retardance UL94HB).
: Bottom contact
: Bottom contact, halogen-free
(Flame retardance UL94V-0).
4
5
6
7
4 Number of positions : 4 to 34
5 Contact pitch : 0.5mm
6 Termination type
SH : SMT horizontal mounting type
7 Plating specifications
(50)…Gold plating with nickel barrier
Remarks
UL94V-0
UL94HB
UL94V-0
-------------
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Connector Dimensions
A±0.15
B
H
(1.95)
0.5
(3.2)
∞Number of contacts
(0.15)
0.15 H
Number of contacts indicator
(3.8)
HRS mark
Cav No.
1±0.1
A * *
0.5
(0.15)
(1.75)
2.9
0.3
2.9
(C)
0.1
1
D±0.1
Note
Note
Note
Note
1
2
3
4
: The coplanarity of each terminal lead within specified dimension is 0.1 mm Max.
: Packaged on tape and reel only. Check packaging specification.
: Slight variations in color of the plastic compounds do not affect form, fit or function of the connector.
: After reflow, the terminal plating may change color, however this does not represent a quality issue.
All dimensions: mm
Part Number
FH34S-4S-0.5SH(50)
FH34S-6S-0.5SH(50)
FH34S-7S-0.5SH(50)
FH34S-8S-0.5SH(50)
FH34S-11S-0.5SH(50)
FH34S-14S-0.5SH(50)
FH34S-16S-0.5SH(50)
FH34S-20S-0.5SH(50)
FH34S-22S-0.5SH(50)
FH34S-23S-0.5SH(50)
FH34S-24S-0.5SH(50)
FH34S-26S-0.5SH(50)
FH34S-30S-0.5SH(50)
FH34S-32S-0.5SH(50)
FH34S-34S-0.5SH(50)
FH34SJ-4S-0.5SH(50)
FH34SJ-6S-0.5SH(50)
FH34SJ-8S-0.5SH(50)
FH34SJ-30S-0.5SH(50)
FH34SW-4S-0.5SH(50)
FH34SW-12S-0.5SH(50)
FH34SR-22S-0.5SH(50)
FH34SRJ-4S-0.5SH(50)
FH34SRJ-6S-0.5SH(50)
FH34SRJ-8S-0.5SH(50)
CL No.
580-1203-2-50
580-1205-8-50
580-1224-2-50
580-1204-5-50
580-1213-6-50
580-1206-0-50
580-1211-0-50
580-1217-7-50
580-1216-4-50
580-1228-3-50
580-1210-8-50
580-1212-3-50
580-1201-7-50
580-1208-6-50
580-1207-3-50
580-1237-4-50
580-1234-6-50
580-1235-9-50
580-1239-0-50
580-1225-5-50
580-1233-3-50
580-1240-9-50
580-1238-7-50
580-1236-1-50
580-1231-8-50
Number of Contacts
4
6
7
8
11
14
16
20
22
23
24
26
30
32
34
4
6
8
30
4
12
22
4
6
8
A
4
5
5.5
6
7.5
9
10
12
13
13.5
14
15
17
18
19
4
5
6
17
4
8
13
4
5
6
B
1.5
2.5
3
3.5
5
6.5
7.5
9.5
10.5
11
11.5
12.5
14.5
15.5
16.5
1.5
2.5
3.5
14.5
1.5
5.5
10.5
1.5
2.5
3.5
C
2.53
3.53
4.03
4.53
6.03
7.53
8.57
10.57
11.57
12.07
12.57
13.57
15.57
16.53
17.53
2.53
3.53
4.53
15.57
2.53
6.53
11.57
2.53
3.53
4.53
D
3.38
4.38
4.88
5.38
6.88
8.38
9.38
11.38
12.38
12.88
13.38
14.38
16.38
17.38
18.38
3.38
4.38
5.38
16.38
3.38
7.38
12.38
3.38
4.38
5.38
Tape and reel packaging (5,000 pieces/reel).
Order by number of reels.
3
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Recommended PCB mounting pattern and metal mask dimensions
(0.25)
(2.9)
(0.15)
0.8±0.05
(0.065)
(0.185)
(0.15)
∞Number of contacts
0.3±0.05
0.1 J
0.25±0.03
(Metal mask)
(0.25)
0.65±0.03
(Metal mask)
J
0.5
3.3±0.05
0.8±0.05
Recommended metal mask thickness: t=0.1
B
E±0.1
F±0.1
(A)
■Recommended FPC/FFC Dimensions
G±0.05
0.
R
0.3±0.03
2-
0.3±0.03
H
(Uncover area)
1.5±0.3
2
B±0.03
0.5±0.03
2.5MIN(Stiffener)
0.5±0.07
Note 1 : Stiffener dimension should be 2.5mm min., and H dimension should be 0.5mm for improved flexibility of FPC.
Note 2 : When using the FPC/FFC in FH34S or FH19SC connectors, the exposed area inserted in either connector is 2.5mm ±
0.3mm and the stiffener is 3.5mm min.
Part Number
FH34S-4S-0.5SH(50)
FH34S-6S-0.5SH(50)
FH34S-7S-0.5SH(50)
FH34S-8S-0.5SH(50)
FH34S-11S-0.5SH(50)
FH34S-14S-0.5SH(50)
FH34S-16S-0.5SH(50)
FH34S-20S-0.5SH(50)
FH34S-22S-0.5SH(50)
FH34S-23S-0.5SH(50)
FH34S-24S-0.5SH(50)
FH34S-26S-0.5SH(50)
FH34S-30S-0.5SH(50)
FH34S-32S-0.5SH(50)
FH34S-34S-0.5SH(50)
FH34SJ-4S-0.5SH(50)
FH34SJ-6S-0.5SH(50)
FH34SJ-8S-0.5SH(50)
FH34SJ-30S-0.5SH(50)
FH34SW-4S-0.5SH(50)
FH34SW-12S-0.5SH(50)
FH34SR-22S-0.5SH(50)
FH34SRJ-4S-0.5SH(50)
FH34SRJ-6S-0.5SH(50)
FH34SRJ-8S-0.5SH(50)
4
CL No.
580-1203-2-50
580-1205-8-50
580-1224-2-50
580-1204-5-50
580-1213-6-50
580-1206-0-50
580-1211-0-50
580-1217-7-50
580-1216-4-50
580-1228-3-50
580-1210-8-50
580-1212-3-50
580-1201-7-50
580-1208-6-50
580-1207-3-50
580-1237-4-50
580-1234-6-50
580-1235-9-50
580-1239-0-50
580-1225-5-50
580-1233-3-50
580-1240-9-50
580-1238-7-50
580-1236-1-50
580-1231-8-50
Number of Contacts
4
6
7
8
11
14
16
20
22
23
24
26
30
32
34
4
6
8
30
4
12
22
4
6
8
A
4
5
5.5
6
7.5
9
10
12
13
13.5
14
15
17
18
19
4
5
6
17
4
8
13
4
5
6
B
1.5
2.5
3
3.5
5
6.5
7.5
9.5
10.5
11
11.5
12.5
14.5
15.5
16.5
1.5
2.5
3.5
14.5
1.5
5.5
10.5
1.5
2.5
3.5
E
3.1
4.1
4.6
5.1
6.6
8.1
9.1
11.1
12.1
12.6
13.1
14.1
16.1
17.1
18.1
3.1
4.1
5.1
16.1
3.1
7.1
12.1
3.1
4.1
5.1
All dimensions: mm
F
G
2.5
3.9
3.5
4.9
4
5.4
4.5
5.9
6
7.4
7.5
8.9
8.5
9.9
10.5
11.9
11.5
12.9
12
13.4
12.5
13.9
13.5
14.9
15.5
16.9
16.5
17.9
17.5
18.9
2.5
3.9
3.5
4.9
4.5
5.9
15.5
16.9
2.5
3.9
6.5
7.9
11.5
12.9
2.5
3.9
3.5
4.9
4.5
5.9
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Recommended FPC construction
● Contact FPC manufacturer for specific details.
1. Using Single-sided FPC
FPC : Flexible Printed Circuit
Material Name
Covering film layer
Material
Polyimide
Material Thickness
(µm)
1 mil thick
(25)
Cover adhesive
(25)
Surface treatment
0.2µm thick gold plated over 1
to 5µm thick nickel underplating
Copper foil
Cu
Base adhesive
Thermosetting adhesive
25
Base film
Polyimide
25
3
35
1oz
1 mil thick
35
Reinforcement material adhesive Thermosetting adhesive
Polyimide
Stiffener
7 mil thick
175
Total
2. Using Double-sided FPC
298
FPC : Flexible Printed Circuit
Material
Material Name
Covering layer film
Polyimide
Material Thickness
(µm)
(25)
1 mil thick
Cover adhesive
(25)
Surface treatment
0.2µm thick gold plated over 1
to 5µm thick nickel underplating
Through-hole copper
Cu
Copper foil
Cu
Base adhesive
Thermosetting adhesive
18
Base film
Polyimide
1 mil thick
25
Copper foil
Cu
1/2oz
Cover adhesive
Thermosetting adhesive
25
Covering film layer
Polyimide
25
Reinforcement material adhesive
Thermosetting adhesive
3
15
1/2oz
18
Base adhesive
Stiffener
18
Polyimide
(18)
1 mil thick
50
100
4 mil thick
Total
297
* To prevent release of the FPC due to its bending, use of the double sided FPC with copper foil on the back side is NOT RECOMMENDED.
3. Using FFC
FFC : Flexible Flat Cable
Material Name
Material
Material Thickness
(µm)
Polyester film
Adhesive
(12)
Thermoplastic polyester
Gold plated annealed copper foil
Adhesive
(30)
35
Polyester
30
12
Polyester
Adhesive
Polyester
30
Stiffener
Polyester
188
Total
295
4. Precautions
1. This specification is a recommendation for the construction of the FH34S Series FPC and FFC (t=0.3 ± 0.03).
2. For details about the construction, please contact the FPC/FFC manufacturers.
5
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Packaging Specification
+0.1
0
(1.95)
(1.95)
Unreeling direction
Unreeling direction
0.5
3±
(Ø80)
(Ø380)
Ø1
(Q: INSIDE)
(R: OUTSIDE)
Mounting section
Lead section (400mm min.)
Embossed carrier tape
No connector inserted
(10 pockets min.)
6
1.75±0.1
Flat surface, for placement
with automatic equipment
● Reel Dimensions
End section
M±0.1
(P)
1.5
No connector inserted
(10 pockets min.)
1.7 +0.15
0
Flat surface,
for placement with
automatic equipment
(3.2)
(4)
N±0.1
L±0.3
+
0
0 .1
Ø1
.5
(0.3)
L±0.3
(P)
(0.3)
(2.25)
1.75±0.1
8±0.1
● Embossed Carrier Tape Dimensions
(Tape width of 32mm min.)
M±0.1
4±0.1 2±0.15
(2.25)
Ø1
.5
+
0
0 .1
● Embossed Carrier Tape Dimensions
(Tape width 24mm max.)
Top cover tape
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
All dimensions: mm
Part Number
CL No.
Number of Contacts
L
M
FH34S-4S-0.5SH(50)
FH34S-6S-0.5SH(50)
FH34S-7S-0.5SH(50)
FH34S-8S-0.5SH(50)
FH34S-11S-0.5SH(50)
FH34S-14S-0.5SH(50)
FH34S-16S-0.5SH(50)
FH34S-20S-0.5SH(50)
FH34S-22S-0.5SH(50)
FH34S-23S-0.5SH(50)
FH34S-24S-0.5SH(50)
FH34S-26S-0.5SH(50)
FH34S-30S-0.5SH(50)
FH34S-32S-0.5SH(50)
FH34S-34S-0.5SH(50)
FH34SJ-4S-0.5SH(50)
FH34SJ-6S-0.5SH(50)
FH34SJ-8S-0.5SH(50)
FH34SJ-30S-0.5SH(50)
FH34SW-4S-0.5SH(50)
FH34SW-12S-0.5SH(50)
FH34SR-22S-0.5SH(50)
FH34SRJ-4S-0.5SH(50)
FH34SRJ-6S-0.5SH(50)
FH34SRJ-8S-0.5SH(50)
CL580-1203-2-50
CL580-1205-8-50
CL580-1224-2-50
CL580-1204-5-50
CL580-1213-6-50
CL580-1206-0-50
CL580-1211-0-50
CL580-1217-7-50
CL580-1216-4-50
CL580-1228-3-50
CL580-1210-8-50
CL580-1212-3-50
CL580-1201-7-50
CL580-1208-6-50
CL580-1207-3-50
CL580-1237-4-50
CL580-1234-6-50
CL580-1235-9-50
CL580-1239-0-50
CL580-1225-5-50
CL580-1233-3-50
CL580-1240-9-50
CL580-1238-7-50
CL580-1236-1-50
CL580-1231-8-50
4
6
7
8
11
14
16
20
22
23
24
26
30
32
34
4
6
8
30
4
12
22
4
6
8
16
16
16
16
16
24
24
24
24
24
24
24
32
32
32
16
16
16
32
16
24
24
16
16
16
7.5
7.5
7.5
7.5
7.5
11.5
11.5
11.5
11.5
11.5
11.5
11.5
14.2
14.2
14.2
7.5
7.5
7.5
14.2
7.5
11.5
11.5
7.5
7.5
7.5
N
—
—
—
—
—
—
—
—
—
—
—
—
28.4
28.4
28.4
—
—
—
28.4
—
—
—
—
—
—
P
Q
R
4.3
5.3
5.8
6.3
7.8
9.3
10.3
12.3
13.3
13.8
14.3
15.3
17.3
18.3
19.3
4.3
5.3
6.3
17.3
4.3
8.3
13.3
4.3
5.3
6.3
17.4
17.4
17.4
17.4
17.4
25.4
25.4
25.4
25.4
25.4
25.4
25.4
33.4
33.4
33.4
17.4
17.4
17.4
33.4
17.4
25.4
25.4
17.4
17.4
17.4
21.4
21.4
21.4
21.4
21.4
29.4
29.4
29.4
29.4
29.4
29.4
29.4
37.4
37.4
37.4
21.4
21.4
21.4
37.4
21.4
29.4
29.4
21.4
21.4
21.4
Tape and reel packaging (5,000 pieces/reel).
7
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Temperature Profile
MAX 250ç
250
Temperature(ç)
230ç
200
HRS test condition
Solder method
: Reflow, IR/hot air
Environment
: Room air
Solder composition : Paste, 96.5%Sn/3.0%Ag/0.5%Cu
(Senju Metal Industry, Co., Ltd.'s Part Number:
200ç
M705-221CM5-42-10.5)
150
150ç
100
Test board
: Glass epoxy 25mm∞40mm∞0.8mm thick
Land dimensions
: 0.3mm∞0.8mm
Metal mask
: 0.25∞0.65∞0.1mm thick
The temperature profiles shown are based on the above conditions.
In individual applications the actual temperature may vary, depending
on solder paste type, volume / thickness and board size / thickness.
50
25ç (60 sec.)
0
Consult your solder paste and equipment manufacturer for specific
90 to 120 sec.
Preheating
Start
Time (Seconds)
8
(60 sec.)
Soldering
recommendations.
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Operation and Precautions
Exercise care when handling connectors. Follow recommendations given below.
Operation
Precautions
1. As delivered
Delivered with the actuator
open. There is no need to
operate the actuator prior to
inserting the FPC/FFC.
• Do not close the actuator without the FPC/FPC inserted.
2. FPC/FFC insertion (The top contact specification)
Insert the FPC/FFC with the
conductive surfaces facing
up.
Align the FPC/FFC straight
with the connector and insert
it firmly all the way.
FPC/FFC contact
surfaces face up.
• The contacts are making connection with the FPC/FFC
pads from the top.
Do not insert the FPC/FFC with the pads facing down.
When inserting the FPC/FFC do not twist it. Insert
straight. Improper insertion may cause deformation of the
contacts and connection failures.
• Be sure to insert the FPC/FFC when the actuator is fully
open.
3. Locking
After FPC/FFC insertion, rotate the actuator down to a
full stop, pushing it at the center.
Rotate
• Do not operate the actuator by only one end. Open or
close by pushing at the center.
• Do not try to rotate the actuator past the fully open 90°
position. This will damage the connector, preventing it
from use.
• Do not apply excessive force to the connector when the
actuator is closed.
Push at the center of the actuator.
4. FPC/FFC removal (Lock release)
Carefully rotate the actuator up to 90°, lifting it at the
center.
• Do not operate the actuator from one end only.
• The actuator opens only 90°. Do not attempt to open it
past this angle or grasp it.
• During the opening of the actuator do not press it toward
the connector body. Rotate up at the center.
Raise
Lift at the center
9
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
■Precautions at the Design Stage
(1) Route the FPC/FFC so that a direct pull force
(2) Make sure that there is enough space to insert/remove the FPC/FFC straight.
(3) Follow the recommendations given in this catalog in regard to mounting pattern, metal mask dimensions and FPC/FFC mating
dimensions.
(4) Consult the manufacturer of the FPC/FFC for the details on the flexibility of the specific FPC/FFC.
(5) When designing the board lay-out and spaces in the device assure that there is enough clearances for the actuator to fully
open/close.
■Precautions when mounting connectors on the PCB
◆Handling before mounting on PCB
Insertion of the FPC/FFC or operation of the actuator prior to mounting on the PCB is NOT RECOMMENDED.
◆PC board warpage
Minimize the warpage as much as possible. The connector are straight within 0.1 mm max. Make sure that the mounting area
flatness can accept the connector terminals without causing any failure of the solder joints.
◆Forces on the board
◆When braking the large PC board into individual boards exercise care NOT to damage the installed connectors.
◆When attaching the boards or other components with the screws make sure that any stresses will NOT cause board deflections
affecting the mounting areas of the connector.
Connectors
PCB
◆When hand soldering:
· Do not perform hand soldering with the FPC inserted in the connector.
* Do not apply excessive heat or touch the soldering iron anywhere other than the connector leads.
* Do not use excessive amount of solder or flux compounds.
Operation of the actuator or contacts may be affected by excessive amounts of solder or flux compounds.
10
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
NOTES :
11
FH34(S)Series●0.5 mm Pitch, 1.0 mm above the board Top and Bottom Contact, Back-Flip actuator Flexible Printed Circuit & Flexible Flat Cable ZIF Connectors
USA:
HIROSE ELECTRIC (U.S.A.), INC. Headquarters
2688 Westhills Court, Simi Valley, CA 93065-6235
Phone : +1-805-522-7958
Fax : +1-805-522-3217
http://www.hiroseusa.com
USA:
HIROSE ELECTRIC (U.S.A.), INC. San Jose Office
20400 Stevens Creek Blvd., Ste 250, Cupertino,
CA 95014
Phone : +1-408-253-9640
Fax : +1-408-253-9641
http://www.hiroseusa.com
USA:
HIROSE ELECTRIC (U.S.A.), INC. Detroit Office (Automotive)
37677 Professional Center Drive, Suite #100C
Livonia, MI 48154
Phone : +1-734-542-9963
Fax : +1-734-542-9964
http://www.hiroseusa.com
THE NETHERLANDS:
HIROSE ELECTRIC EUROPE B.V.
Hogehillweg #8 1101 CC Amsterdam Z-O
Phone : +31-20-6557460
Fax : +31-20-6557469
http://www.hiroseeurope.com
GERMANY:
HIROSE ELECTRIC EUROPE B.V. GERMAN BRANCH
Herzog-Carl-Strasse 4 D-73760 Ostfildern
(Scharnhauser Park)
Phone : +49-711-4560-02-1
Fax : +49-711-4560-02-299
http://www.hirose.de
UNITED KINGDOM:
HIROSE ELECTRIC EUROPE B.V. UK BRANCH
First Floor, St Andrews House, Caldecotte Lake
Business Park, Milton Keynes MK7 8LE
Phone : +44-1908-369060
Fax : +44-1908-369078
http://www.hirose.co.uk
CHINA:
HIROSE ELECTRIC (SHANGHAI) CO., LTD.
1601,Henderson Metropolitan,NO.300 ,East Nanjing
Road,Huangpu District, Shanghai,China 200001
Phone : +86-21-6391-3355
Fax : +86-21-6391-3335
http://www.hirose-china.com.cn
CHINA:
HIROSE ELECTRIC (SHANGHAI) CO., LTD. BEIJING BRANCH
A1001, Ocean International Center, Building 56# East 4th
Ring Middle Road, Chao Yang District, Beijing, 100025
Phone : +86-10-5165-9332
Fax : +86-10-5908-1381
http://www.hirose-china.com.cn
CHINA:
HIROSE ELECTRIC TECHNOLOGIES (SHENZHEN) CO., LTD.
Room 09-13, 19/F, Office Tower Shun Hing Square, Di Wang Commercial Centre
5002, ShenNanDong Road, ShenZhen City, Guangdong Province, 518008
Phone : +86-755-8207-0851
Fax : +86-755-8207-0873
http://www.hirose-china.com.cn
HONG KONG:
HIROSE ELECTRIC HONGKONG TRADING CO., LTD.
Room 1001, West Wing, Tsim Sha Tsui Centre, 66
Mody Road, Tsim Sha Tsui East, Kowloon, Hong Kong
Phone : +852-2803-5338
Fax : +852-2591-6560
http://www.hirose-hongkong.com.hk
TAIWAN:
KOREA:
HIROSE KOREA CO., LTD.
1261-10, Jeoungwhang-Dong, Shihung-City,
Kyunggi-Do 429-450
Phone : +82-31-496-7000,7124
Fax : +82-31-496-7100
http://www.hirose.co.kr
SINGAPORE:
HIROSE ELECTRIC SINGAPORE PTE. LTD.
10 Anson Road #26-16 International Plaza 079903
Phone : +65-6324-6113
Fax : +65-6324-6123
http://www.hirose-singapore.com.sg
INDIA:
HIROSE ELECTRIC SINGAPORE PTE. LTD. BANGALORE LIAISON OFFICE
Unit No.03, Ground Floor, Explorer Building International Tech
Park Whitefield Road, Bangalore 560066 Karnataka, India
Phone : +65-6324-6113
Fax : +65-6324-6123
http://www.hirose-singapore.com.sg
®
12
HIROSE ELECTRIC TAIWAN CO., LTD.
103 8F, No.87, Zhengzhou Rd., Taipei
Phone : +886-2-2555-7377
Fax : +886-2-2555-7350
http://www.hirose-taiwan.com.tw
6-3,Nakagawa Chuoh-2-Chome,Tsuzuki-Ku,Yokohama-Shi 224-8540,JAPAN
TEL: +81-45-620-3526 Fax: +81-45-591-3726
http://www.hirose.com
http://www.hirose-connectors.com
The contents of this catalog are current as of date of 03/2012. Contents are subject to change without notice for the purpose of improvements.
Similar pages