Omron G6D-F4B Easy-to-use, space-saving terminal relay with four-point output Datasheet

Terminal Relay
G6D-F4B/G3DZ-F4B
Easy-to-use, Space-saving Terminal
Relay with Four-point Output
Almost the same size as PYF Socket: 31 x 35 x
68 mm (W x H x D)
Each terminal circuit (with coil or contact) is
independent from one another.
Short Bar ensures easy connection of common and
adjacent terminals.
Provided with a terminal cover that prevents
electric-shock accidents.
Relay and MOS FET relay models are available.
LED operation indicator.
Built-in diode absorbs coil surge.
Mounts either on DIN track or screws.
Tool for easy mounting or removal of Relays
provided.
Ordering Information
Model Number Legend:
G6D/G3DZ-jj
1
1.
2
Terminal Form
F:
Flat type
Output
Relay
e ay ou
output
u
2.
Contact configuration
SPST-NO
S
S
O
4
Terminals
Phillipss head
ead screw
sc e
t
terminal
i l
Power
o e MOS
OS FET relay
e ay
output
t t
Note:
Number of Relays Mounted
4B:
4
Rated coil voltage
Model
G6D-F4B
G6
12 VDC
24 VDC
G3DZ-F4B
G3
12 VDC
24 VDC
When ordering add the rated coil voltage to the model number.
Example: G6D-F4B 24 VDC
Rated coil voltage
Accessories (Order Separately)
Replacement Relays
Applicable Terminal Relay
G6D-F4B
G6
Rated voltage
Model
G6D-1A (see note)
G6
o e)
12 VDC
24 VDC
G6D-1A-AP (see note)
G6
o e)
12 VDC
24 VDC
G3DZ-F4B
G3
G3DZ-2R6PL
G3
6
12 VDC
24 VDC
Note:
Error rate (P level) for the G6D-1A is 5 V at 10 mA and that for the G6D-1A-AP is 5 V at 1 mA.
Short Bar
Applicable Terminal Relay
G6D-F4B
Model
G6D-4-SB
G3DZ-F4B
1
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
Specifications
Ratings
Coil Ratings (per G6D Relay)
Rated voltage
Rated current
Coil resistance
12 VDC
18.7 mA
720 Ω
24 VDC
10.5 mA
2,880 Ω
Note:
Must operate
voltage
70%
0% max.
a
(
(see
note
t 1)
Must release
voltage
10%
0% min.
Max. voltage
130%
30%
Power
consumption
Approx.
o 200
00 mW
1. The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down.
2. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%.
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply.
There is no continuous allowance.
5. The rated current includes the terminal’s LED current.
Contact Ratings (per G6D Relay)
Item
Resistive load (cosφ = 1)
Rated load
3 A at 250 VAC, 3 A at 30 VDC
Rated carry current
5A
Max. switching voltage
250 VAC, 30 VDC
Max. switching current
5A
Max. permissible capacity (reference value)
1,250 VA, 150 W
Error rate (reference value) (see note)
5 VDC, 1 mA
Note:
This value is for a switching frequency of 120 times per minute.
Power MOS FET Relay Specifications
Input (per G3DZ Power MOS FET Relay)
Rated voltage
Operating voltage
Must operate
voltage level
12 VDC
9.6 to 14.4 VDC
9.6 VDC max.
24 VDC
19.2 to 28.8 VDC
19.2 VDC max.
Note:
The rated current includes the terminal’s LED current.
Output (per G3DZ Power MOS FET Relay)
Load voltage
3 to 264 VAC
3 to 125 VDC
2
Load current
100 µ to 0.3 A
Inrush current
6 A (10 ms)
Must release
voltage level
1 VDC
C min.
Input impedance
Rated current
2 kΩ±20%
8.0 mA±20%
4 kΩ±20%
8.2 mA±20%
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
Characteristics
G6D-F4B
Item
e
Relay output
Contact resistance (see note 2)
100 mΩ max.
Must operate time (see note 3)
10 ms max.
Release time (see note 3)
10 ms max.
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric
e ec c s
strength
e g
2,000 VAC, 50/60 Hz for 1 min between coil and contacts.
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
50 µs)
Impulse withstand voltage (between
coil and contacts)
4,000 V (1.2
Vibration resistance
Destruction:10 to 55 Hz, 1.5-mm double amplitude
Malfunction:10 to 55 Hz, 1.5-mm double amplitude
Shock
S
oc resistance
es s a ce
Destruction:500 m/s2
Malfunction:100 m/s2
Life
e expectancy
e pec a cy
Mechanical:20,000,000 operations min. (at 18,000 operations/hr)
Electrical:
100,000 operations min. (3 A at 250 VAC, resistive load)
100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr)
Ambient temperature
Operating: –25°C to 55°C (with no icing)
Storage:
–25°C to 55°C (with no icing)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 65 g
Note:
1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC
3. Ambient temperature condition: 23°C
G3DZ-F4B
Item
e
Power MOS FET relay output
Must operate time
10 ms max.
Release time
15 ms max.
Output ON-resistance
2.4 Ω max.
Leakage current at OFF state
10 µA max. (at 125 VDC)
Insulation resistance
100 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between input and output terminals
Vibration resistance
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
500 m/s2
Ambient temperature
Operating: –25°C to 55°C (with no icing)
Storage:
–25°C to 55°C (with no icing)
Ambient humidity
Operating: 45% to 85%
Weight
Approx. 65 g
3
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
Engineering Data
G6D-F4B
DC resistive load
AC resistive load
Life Expectancy
Life expectance (x10 4 operations)
Switching current (A)
Max. Switching Capacity
250 VAC/30 VDC resistive load
Switching current (A)
Switching voltage (V)
G3DZ-F4B
Load current (A)
Ambient temperature (°C)
4
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value
if it occurs repetitively.)
Inrush current (A. Peak)
Load Current vs. Ambient Temperature
Characteristics
Energizing time (ms)
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
G6D-F4B
G3DZ-F4B
Mounting Dimensions
16, M3 Phillips
head screws
Two, 4 dia. or M3.5 holes
Terminal Arrangement/
Internal Connections
(Top View)
Input side
68 max.
Output side
31 max.
35 max.
Note:
Make sure that the polarity
of the coil is correct.
Accessories
G6D-4-SB Short Bar
Applicable
model
G6D-F4B
Model
G6D-4-SB
G6
S
G3DZ-F4B
5
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
Precautions
Wiring
Coil Voltage
Be sure to turn OFF the power when wiring the Unit and do not touch
the charged terminals of the Unit. Otherwise, an electric shock may
result.
Do not apply overvoltage to the input terminals. Otherwise, the Unit
may malfunction or burn.
Make sure not to impose voltage exceeding the permissible voltage
on the coil continuously.
Do not connect any inductive load in parallel to the coil input as
shown in the following example or power supply with a surge voltage. Otherwise, the surge absorption diode will be damaged.
Relay Models
Do Not Use the Following Circuit
Do not connect the Unit to loads exceeding the rated switching capacity (switching voltage or current). Otherwise, faulty insulation,
contact weld, or faulty contact of Relays, or damage to Relays may
result, or the Relays may malfunction or burn.
The life of Relays varies with the switching condition. Test the
Relays under the actual operating conditions before using the
Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or
cause the Relays to burn.
Do not use the Unit in locations with inflammable gas. Otherwise, a
fire or explosion due to the heat of the Relays or sparks from the
Relays may result when they are switched.
SSR Output (Power MOS FET Relay Model)
Do not connect the Unit to loads consuming a total current exceeding the rated output current of the Unit. Otherwise, the output element of the Unit may be damaged and a short or open-circuit malfunction may result.
If the Unit is connected to a DC inductive load, connect a diode to the
Unit to protect the Unit from counter-electromotive voltage, otherwise the counter-electromotive voltage may damage the output element and a short or open-circuit malfunction may result.
Correct Use
Mounting
When mounting two or more Units, reduce the current and ON duty
and provide an appropriate distance between the Units so that the
ambient temperature will not exceed 55°C.
Relay Replacement
Use the Relay Removal Tool provided with the Unit to dismount a
Relay.
Be sure to turn OFF the power to the Unit before replacing a Relay.
When mounting a Relay, insert the Relay vertically so that the relay
terminals will come in contact with the socket contact pins properly.
Do not mount Relays that are different to one another in voltage.
Wiring
Pay utmost attention not to make mistakes with the polarity of the
input terminals.
6
Inductive load
G6D coil
Coil surge
absorption
diode
Handling
Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction.
Make sure that all the Relays are properly mounted before use.
Screw Tightening Torque
Tighten each terminal screw to a torque of 0.78 to 1.18N S m.
Tighten each mounting screw to a torque of 0.59 to 0.98 N S m.
Installation Environment
Do not install the Unit in the following locations. Otherwise, damage
to the Unit may result or the Unit may malfunction.
Locations with direct sunlight.
Locations with an ambient temperature range not within –25°C to
55°C.
Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 45% to
85%.
Locations with corrosive or inflammable gas.
Locations with excessive dust, salinity, or metal powder.
Locations with vibration or shock affecting the Unit.
Locations with water, oil, or chemical sprayed on the Unit.
Disassembly, Repair, and Modification
Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction.
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
7
G6D-F4B/G3DZ-F4B
G6D-F4B/G3DZ-F4B
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J115-E1-1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Industrial Control Components Division
28th Fl., Crystal Tower Bldg.,
1-2-27, Shiromi, Chuo-ku,
Osaka 540-6028 Japan
Phone: (81)6-6949-6025 Fax: (81)6-6949-6029
8
Printed in Japan
0799-1M (0799) a
Similar pages