Mean Well GC120A48-AD1 120w single output battery charger Datasheet

GC120
120W Single Output Battery Charger
series
Features :
2 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.97
No load power consumption<0.5W
3 pole AC inlet IEC320-C14
Class I power ( with earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Fully enclosed plastic case
2 color LED indicator for charging status
Approvals: TUV / UL / CB / FCC / CE
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
( for GC120Axx-AD1 only)
ORDER NO.
OUTPUT CONNECTOR
SAFETY
GC120Axx-R7B (standard model)
4pin power din
TUV / CB / FCC / CE
GC120Axx-AD1 (optional model)
Anderson connector
UL / TUV / CB / FCC / CE
GC120Axx-
xx=12,24,48 ;
=R7B,AD1
SPECIFICATION
ORDER NO.
GC120A12-
GC120A24-
GC120A48-
GC120A12
13.6V
GC120A24
27.2V
GC120A48
54.4V
RECOMMENDED BATTERY
40 ~ 100Ah
CAPACITY
Note.2
20 ~ 65Ah
10 ~ 35Ah
CONTINUOS OUTPUT
CURRENT (Typ.)
7.5A
4.42A
2.21A
102W
120.2W
120.2W
SAFETY MODEL NO.
DC VOLTAGE (Typ.)
OUTPUT
RATED POWER
LED INDICATOR
VOLTAGE RANGE
INPUT
Charging(CC) : RED
Floating charging(CV) : GREEN
Note.3 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97 / 230VAC
EFFICIENCY (Typ.)
86.5%
AC CURRENT
INRUSH CURRENT (max.)
1.4A / 115VAC
LEAKAGE CURRENT(max.)
0.75mA / 240VAC
OVERLOAD
OVER VOLTAGE
NOTE
Protection type : Hiccup mode, recovers automatically after fault condition is removed
14 ~ 16.5V
29 ~ 33V
59 ~ 69V
Protection type : Shut down o/p voltage, re-power on to recover
100
10 (RTH2) detect on inside ambient temperature
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note. 5)
EMC EMISSION
EMC IMMUNITY
CONNECTOR
91%
70A / 230VAC
OVER TEMPERATURE
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OTHERS
90%
0.7A / 230VAC
90 ~ 110% rated output power
Note.4
Protection type : Constant current limiting recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
PF>0.99 / 115VAC at full load
-40 ~ +85
, 10 ~ 95% RH
0.03% / (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC120Axx-AD1 only), TUV EN60950-1 approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
400.7Khrs min. MIL-HDBK-217F(25
)
MTBF
DIMENSION
PACKING
PLUG
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
See page 2 ; Other type available by customer requested
CABLE
See page 2 ; Other type available by customer requested
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. This is MeanWell's suggested range, please consult your battery manufacturer for their suggestions about maximum charging current limitation.
3. Derating may be needed under low input voltage. Please check the derating curve for more details.
4. Constant current operation region is within 50~100% rated output voltage.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GC120-SPEC 2011-08-09
GC120
120W Single Output Battery Charger
Mechanical Specification
Case No.947A
35
series
Unit:mm
UL2464 18AWGx4C 1200 50mm
167
67
30 3mm
(R7B)
POWER LED
35
SJTW 18AWGx2C 1200 50mm
167
67
30 3mm
(AD1)
POWER LED
Charging Curve
Plug Assignment
DC output connector (standard)
(V,I)
R7B
(KYCON KPP-4S or equivalent)
Stage 1
Stage 2
Constant Current Area
Constant Voltage Area
PIN NO. OUTPUT
2
1
3
4
1,4
+V
2,3
-V
V
100%
AC FG
-V connected to AC FG
Fast Charging
DC output connector (optional)
10%
AD1
[ housing: Anderson 1327FP(red), 1327G6FP(black)
contacts: Anderson 261G2 (45A) or equivalent ]
Red(+V)
Float Charging
Red
Color of LED
I
TIME
Green
Black(-V)
Derating Curve
Static Characteristics
100
230VAC
100
85
80
80
70
100VAC
LOAD (%)
LOAD (%)
60
50
40
20
-30
10
20
30
40 45 50
60
AMBIENT TEMPERATURE ( )
70
(HORIZONTAL)
60
50
40
85
95
100
110
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
File Name:GC120-SPEC 2011-08-09
Similar pages