LEM HTA600-S Current transducer Datasheet

Current Transducer HTA 100 .. 1000-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN = 100 .. 1000 A
Electrical data
Type
Primary nominal
Primary current, RoHS since
current rms
measuring range
date code
IPN (A)
IPM (A)
HTA 100-S
100
± 300
46179
HTA 200-S
200
± 600
46170
HTA 300-S
300
± 900
46097
HTA 400-S
400
± 1000
46100
HTA 500-S
500
± 1000
46083
HTA 600-S
600
± 1000
46222
HTA 1000-S
1000
± 1000
46118
VOUT
Output voltage (Analog) @ ± IPN
± 4
V
RL
Load resistance
TA = 0 .. + 70°C
> 1
kΩ
TA = - 25 .. + 85°C
> 3
kΩ
VC
Supply voltage (± 5 %)
± 15
V
IC
Current consumption
< 25
mA
RIS
Isolation resistance @ 500 VDC
> 500
MΩ
Accuracy - Dynamic performance data
X
Accuracy 1) @ IPN , TA = 25°C , @ ± 15 V
± 1
%
εL
Linearity error 1) (0 .. ± IPN)
± 0.5
%
VOE
Electrical offset voltage, @ IP = 0, TA = 25°C
< ± 10
mV
VOH
Hystersis offset voltage @ IP = 0,
after an excursion of 3 x IPN
< ± 10
mV
TCVOE Temperature coefficient of VOE
TA = - 25 .. + 85°C < ± 1
mV/K
TCVOUT Temperature coefficient of VOUT
TA = - 25 .. + 85°C < ± 0.05
%/K
tr
Response time to 90 % of IPN step
< 3
µs
di/dt di/dt accurately followed
> 50
A/µs
BW
Frequency bandwidth (- 3 dB) 2)
DC .. 50
kHz
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
Standards
Safety
EMC
Deviation in output when tested to EN 61000-4-3
- 25 .. + 85
°C
- 25 .. + 85
°C
230
g
EN 50178(1994)
EN 50082-2(1992)
EN 50081-1(1992)
< 25
% of IPN
Features
●● Open loop transducer using Hall
effect
●● Panel mounting-Horizontal or
Vertical
●● Insulated plastic case recognized
according to UL 94-V0
Advantages
●●
●●
●●
●●
●●
●●
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external
interference
●● Current overload capability
●● Low power consumption
●● Wide dynamic range,
100 to 1000 A in one package.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Notes: 1)Excludes the electrical offset
2)
Refer to derating curves in the technical file to avoid excessive core
heating at high frequency.
090430/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
www.lem.com
Current Transducer HTA 100 .. 1000-S
Isolation characteristics
Vd
Vw
dCp
dCI
CTI
Rms voltage for AC isolation test, 50 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
Creepage distance
Clearance distance
Comparative Tracking Index (group IIIa)
4.0
> 7.3
Min
7.2
7.2
600
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category III
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
600 V
600 V
Reinforced isolation
300 V
300 V
dCp, dCI, Vw
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
090430/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HTA 100 .. 1000-S (in mm. 1 mm = 0.0394 inch)
Dimensions HTA 100..1000-S (in mm. 1 mm = 0.0394 inch)
Bottom view
Left view
Secondary terminals
Secondary terminals
Front view
Mechanical characteristics
●● General tolerance
± 0.5 mm
characteristics Ø 32 mm
●● Mechanical
Primary through-hole
●● Connection of secondary
Molex 5045-04A
• General tolerance
± 0.5 mm
• Primary through-hole
Ø 32 mm
• Connection of secondary
Molex 5045-04A
Terminal 1
Terminal 1
Terminal 2
Terminal
Terminal2 3
Terminal3 4
Terminal
: supply voltage + 15 V
: Supply voltage + 15 V
: supply voltage - 15 V
: Supply: output
voltage - 15 V
:
0V
: Output
Terminal 4
: 0V
Remarks
●● VOUT is positive when IP flows in the direction of the arrow.
●●Safety
Temperature of the primary conductor should not exceed
90°C.
●● This is a standard model. For different versions (supply
voltages,
secondary
connections,
unidirectional equipment
This
transducer
must be
used in electric/electronic
measurements,
operating
temperatures,
etc.,) please
with respect to applicable standards and safety
requirements
contact
us.
in accordance with the manufacturer's operating instructions.
Remarks
• VOUT is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
90°C.
• This is a standard model. For different versions (supply
voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us.
090430/6
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 3/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Page 2/2
080516/5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Similar pages