LEM HXS20-NP Current transducer Datasheet

Current Transducer HXS 20-NP
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 5-10-20 A
All Data are given with a RL = 10 kΩ
Electrical data
IPN
IPM
VOUT
GTH
VREF
RL
ROUT
CL
VC
IC
Primary nominal current rms
Primary current, measuring range
Analog Output voltage @ IP
Theoretical sensitivity Reference voltage 1) Ouput voltage
Ouput impedance
Load impedance
Load resistance
Output internal resistance
Capacitive loading (± 20 %)
Supply voltage (± 5 %) 2)
Current consumption @ VC = 5V
± 20
A
± 60
A
VOE ± (0.625. IP/ IPN) V
0.625
V/ IPN
2.5 ± 0.025
V
typ. 200
Ω
≥ 200
kΩ
≥ 2
kΩ
< 5
Ω
= 4.7
nF
5
V
19
mA
Accuracy - Dynamic performance data
Accuracy 3) @ IPN , TA = 25°C
εL
Linearity error
0 .. IPN
0 .. 3 x IPN
TCVOE Temperature coefficient of VOE
(+25.. 105°C)
(-40.. +25°C)
TCVREF Temperature coefficient of VREF
(+25.. 105°C)
(-40.. +25°C)
TCVOE/VREFTemperature coefficient of VOE /VREF TCG
Temperature coefficient of G VOE
Electrical offset voltage @ IP = 0, TA = 25°C
VOM
Magnetic offset voltage @ IP = 0
after an overload of 3 x IPN
tra
Reaction time to 10 % of IPN step
tr
Response time to 90 % of IPN step
di/dt
di/dt accurately followed
Vno
Output voltage noise (DC .. 10 kHz)
(DC .. 1 MHz)
BW
Frequency bandwidth (- 3 dB) 4)
X
≤ ± 1
%
≤ ± 0.5
%
≤ ± 1
%
≤ ± 0.4
mV/K
≤ ± 0.525
mV/K
≤ ± 0.01
%/K
≤ ± 0.015
%/K
≤ ± 0.15
mV/K
≤ ±0.05% of reading//K
VREF ± 0.0125
V
< ± 0.7
< 3
< 5
> 50
< 20
< 40
DC .. 50
%
µs
µs
A/µs
mVpp
mVpp
kHz
General data
TA
TS
m
Ambient operating temperature 5)
Ambient storage temperature
Mass
Standards Notes:
1)
- 40 .. + 105
°C
- 40 .. + 105
°C
10
g
EN 50178: 1997
It is possible to overdrive VREF with an external reference voltage between 1.5V 2.8V providing its ability to sink or source approximately 5 mA.
2)
Maximum supply voltage (not operating) < 6.5 V
3)
Excluding Offset and Magnetic offset voltage
4)
Small signal only to avoid excessive heatings of the magnetic core.
5)
UL recognized with surrounding temperature until +85℃
Features
●● Hall effect measuring principle
●● Multirange current transducer
through PCB pattern lay-out
●● Galvanic isolation between
primary and secondary circuit
●● Isolation test voltage 3500 V
●● Low power consumption
●● Extremely low profile < 11 mm
●● Single power supply + 5 V
●● Fixed offset & sensitivity
●● Isolated plastic case recognized
according to UL 94-V0.
Advantages
●● Small size and space saving
●● Only one design for wide current
ratings range
●● High immunity to external
interference
●● Internal & external reference.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Page 1/3
120416/21
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Current Transducer HXS 20-NP
Isolation characteristics
Vd
dCp
dCI
CTI
Rms voltage for AC isolation test, 50 Hz, 1 min
Creepage distance
Clearance distance
Comparative Tracking Index (group I)
3.5
> 5.5
> 5.5
> 600
kV
mm
mm
V
Applications examples
According to EN 50178, IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Single isolation
600 V
600 V
Reinforced isolation
300 V
150 V
According to UL508 standard and following conditions: Max. Voltage 600V
●● Over voltage category OV 3
●● Pollution degree PD2
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
120416/21
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HXS 20-NP (in mm)
Required connection circuit
Primary current
Number of
primary turns
1
2
nominal
IPN [ A ]
maximum
IP [ A ]
20
60
10
4
30
5
15
Mechanical characteristics
●● General tolerance
●● Transducer fastening &
connection of primary jumper
●● Transducer fastening &
connection of secondary
Primary
resistance
Primary insertion
inductance
RP [ mΩ ]
LP [ µH ]
0.05
0.025
0.2
1
Recommended PCB
connections
IN
1
3
5
7
IN
2
1
4
3
6
5
8
7
OUT
2
1
4
3
6
5
8
7
OUT
IN
2
4
6
8
OUT
0.1
0.4
Recommended PCB hole
± 0.2 mm
8 pins □ 1.2 mm
(corner R 0.4mm)
4 pins 0.5 x 0.25 mm
●● Primary PCB hole
●● Secondary PCB hole
Remarks
Ø 1.5 mm
Ø 0.7 mm
●● VOUT is positive when IP flows from terminals 1,3, 5, 7 (IN)
to terminals 2, 4, 6, 8 (OUT).
●● Temperature of the primary conductor should not exceed
120°C.
Page 3/3
120416/21
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Similar pages