LEM LAH100-P Current transducer Datasheet

Current Transducer LAH 100-P
IPN = 100 A
For the electronic measurement of currents: DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
16052
Electrical data
IPN
IPM
RM
Primary nominal current rms
Primary current, measuring range
Measuring resistance @
100
0 .. 160
TA = 70°C
TA = 85°C
RM min RM max RM min RM max
1)
with ± 12 V
@ IPN [± A DC ]
@ IPN [A RMS ] 2)
with ± 15 V
@ IPN [± A DC ]
@ IPN [A RMS ] 2)
@ IP < IPN 3)
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
ISN
KN
VC
IC
0
0
20
20
63
11
120
51
0
0
45
45
57
5
114
45
50
1 : 2000
± 12 .. 15
10 (@ ± 15V)
A
A
ε
Accuracy 4) @ IPN, TA = 25°C
Linearity error
Ω
Ω
Ω
Ω
mA
V
+ I S mA
L
± 0.25
< 0.15
Typ
IO
IOM
IOT
tr a
tr
di/dt
BW
%
%
Offset current @ TA = 25°C
Magnetic offset current @ IP = 0 and specified RM,
after an overload of 5 x IPN
Temperature variation of IO
0°C .. + 70°C
- 25°C .. + 85°C
Max
± 0.15
mA
± 0.10 ± 0.15
± 0.10 ± 0.40
± 0.10 ± 0.50
mA
mA
mA
Reaction time @ 10 % of IPN
Response time 5) to 90 % of IPN step
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 200
< 500
> 200
DC .. 200
ns
ns
A/µs
kHz
General data
TA
TS
RS
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance
m
Mass
Standards
Notes:
1)
2)
3)
4)
5)
@ TA = 70°C
@ TA = 85°C
• Closed loop (compensated) current
transducer using the Hall effect
Accuracy - Dynamic performance data
X
Features
- 25 .. + 85
°C
- 40 .. + 90
°C
115
Ω
121
Ω
24
g
EN 50178: 1997
• Printed circuit board mounting
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Application domain
• Industrial.
For 10 s, with R M ≤ 25 Ω (V C = ± 15 V)
50 Hz Sinusoidal
The measuring resistance RM min may be lower
(see "LAH Technical Information" leaflet)
Without IO & IO M
With a di/dt of 100 A/µs.
071129/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
Page 1/3
w w w .lem.com
Current Transducer LAH 100-P
Isolation characteristics
Vd
Vw
Ve
Rms voltage for AC isolation test, 50/60 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction voltage rms @ 10pC
5
12
>2
dCp
dCl
CTI
Creepage distance 6)
Clearance distance 6)
Comparative Tracking Index (Group III a)
Min
11.75
11.75
175
kV
kV
kV
mm
mm
Application examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
• Over voltage category OV 3
• Pollution degree PD2
• Non-uniform field
EN 50178
IEC 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
1000 V
1000 V
Reinforced isolation
500 V
500 V
dCp, dCI
Note : 6) On PCB with soldering pattern UTEC93-703.
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
071129/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions LAH 100-P
(in mm. 1 mm = 0.0394 inch)
Connection
Bottom view
Left view
Front view
Number
Primary current
N o m i n a l
Turns
Primary
Primary insertion
of primary
nominal
maximum
output current
r a t i o
resistance
i n d u c t a n c e
t u r n s
IPN [ A ]
IP
ISN
KN
RP
LP
1
100
[A]
160
[ mA ]
50
1 : 2000
Mechanical characteristics
• General tolerance
• Fastening & connection of primary
Recommended PCB hole
• Fastening & connection of secondary
Recommended PCB hole
[ mΩ ]
0.08
[ µH ]
0.007
Remarks
± 0.2 mm
6 pins 1.4 x 1 mm
2 mm
3 pins 0.7 x 0.6 mm
1.2 mm
• IS is positive when IP flows from terminals "IN" to terminals
"OUT".
• The jumper temperature and PCB should not exceed 100°C.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
Page 3/3
071129/10
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Similar pages