LEM LF205-S Current transducer Datasheet

Current Transducer LF 205-S
For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic separation between the primary circuit and the secondary
circuit.
Features
Electrical data
IPN
Primary nominal rms current
IPM
Primary current, measuring range
RM
Measuring resistance @
with ± 12 V
@ ± 200 A max
@ ± 420 A max
with ± 15 V
@ ± 200 A max
@ ± 420 A max
ISN
Secondary nominal rms current
KN
Conversion ratio
UC
Supply voltage (+ 5 %)
IC
Current consumption @ ± 15 V
200
A
0 .. ± 420
A
TA = 70 °C
TA = 85 °C
RM min RM max RM min RM max
0
71
0
69
Ω
0
14
0
12
Ω
0
100
23
98
Ω
0
28
23
26
Ω
100
mA
1 : 2000
± 12 .. 15
V
17 + IS
mA
Accuracy - Dynamic performance data
XG
εL
IO
IOM
IOT
tra
tr
di/dt
BW
IPN = 200 A
Overall accuracy @ IPN, TA = 25 °C
± 0.5
Linearity error
< 0.1
Typ
Max
Offset current @ IP = 0, TA = 25 °C
± 0.2
Magnetic offset current 1) @ IP = 0 and specified RM,
after an overload of 3 x IPN
± 0.1
Temperature variation of IO
- 40 °C .. + 85 °C ± 0.12 ± 0.4
Reaction time to 10 % of IPN step
< 500
Response time 2) to 90 % of IPN step
< 1
di/dt accurately followed
> 100
Frequency bandwidth (- 3 dB)
DC .. 100
%
%
mA
mA
mA
ns
µs
A/µs
kHz
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
RS
Secondary coil resistance
@ TA = 70 °C
@ TA = 85 °C
m
Mass
Standard
- 40 .. + 85
°C
- 40 .. + 90
°C
33
Ω
35
Ω
78
g
EN 50178: 1997
●● Closed loop (compensated)
current transducer using the Hall
effect
●● Insulating plastic case recognized
according to UL 94-V0.
Advantages
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
●● Current overload capability.
Applications
●● AC variable speed drives and
servo motor drives
●● Static converters for DC motor
drives
●● Battery supplied applications
●● Uninterruptible Power Supplies
(UPS)
●● Switched Mode Power Supplies
(SMPS)
●● Power supplies for welding
applications.
Application domain
●● Industrial.
Notes: 1) The result of the coercive force (Hc) of the magnetic circuit
2)
With a di/dt of 100 A/µs.
Nº 97.14.44.000.0
8June2013/version 17
Page 1/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Current Transducer LF 205-S
Isolation characteristics
Rms voltage for AC insulation test, 50/60 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction voltage rms @ 10 pC
Creepage distance
Clearance
Comparative Tracking Index (group IIIa)
Ud
ÛW
Ue
dCp
dCI
CTI
3.5
8.8
> 2
Min
11
10.2
175
kV
kV
kV
mm
mm
Applications examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
●● Over voltage category OV 3
●● Pollution degree PD2
●● Non-uniform field
EN 50178
IEC 61010-1
Rated insulation voltage
Nominal voltage
Basic insulation
500 V
500 V
Reinforced insulation
250 V
250 V
dCp, dCI, ÛW
Safety
This transducer must be used in limited-energy secondary circuits according to
IEC 61010-1.
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer’s
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
8June2013/version 17
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LF 205-S (in mm)
:
dCI
dCp
IS
IP
RM
UC
UC
dCI
dCp
IP
Connection
IP
IS
RM
UC
UC
Mechanical characteristics
●● General tolerance
●● Transducer fastening
Vertical position
Remarks
± 0.2 mm
2 holes Ø 4.3 mm
2 steel screws M4
Recommended fastening torque 2.3 N·m
Or
4 holes Ø 1.9 mm
depth: 7 mm
4 screws PTKA 25
length: 6 mm
●● Transducer fastening
Horizontal position
4 holes Ø 4.3 mm
4 steel screws M4
Recommended fastening torque 3.2 N·m
Or
4 holes Ø 1.9 mm
4 screws PTKA 25
min length: 11.5 mm with
thickness of fixed plate
Recommended fastening torque 0.7 N·m
●● Primary through-hole
Ø 15.5 mm
●● Connection of secondary
Molex 6410
3 Tin plated pins
8June2013/version 17
●● IS is positive when IP flows in the direction of the arrow.
●● Temperature of the primary conductor should not exceed
100 °C.
●● Dynamic performances (di/dt and response time) are
best with a single bar completely filling the primary hole.
●● This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 3/3
www.lem.com
dCI