MORNSUN LH20-10A15 20(25)w, ac-dc converter Datasheet

AC/DC Converter
LH20(25) Series
20(25)W, AC-DC converter
FEATURES
Universal input range:85~264VAC, 100~370VDC
Regulated output, low ripple and noise
Efficiency up to 87%
Over-current, short circuit and over- voltage
protection
 Plastic case, meets UL94V-0
 IEC60950, UL60950, EN60950 Approval
 PCB mounting, Chassis mounting, DIN-Rail mounting




CB
RoHS
LH 20-25 series -----a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input
voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, which meet
IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and it’s widely used in industrial, office and civil applications. For harsh
EMC environment, the application circuit in the datasheet is strongly recommended.
Selection Guide
Certification
UL/CE/CB
Part No.*
UL/CE/CB
Nominal Output Voltage and
Current
(Vo1/Io1)
(Vo2/Io2)
Efficiency
(230VAC, %/Typ.)
Max. Capacitive
Load(µF)
Vo1
Vo2
LH20-10B03
13.53W
3.3V/4100mA
--
74
48000
--
LH20-10B05
17.5W
5V/3500mA
--
78
12240
--
LH20-10B09
9V/2100mA
--
80
7200
--
LH20-10B12
12V/1600mA
--
82
5400
--
LH20-10B15
15V/1300mA
--
83
2720
--
LH20-10B24
24V/850mA
--
85
1840
--
LH20-10A05
+5V/2000mA
-5V/2000mA
75
8000
8000
LH20-10A12
+12V/830mA
-12V/830mA
82
960
960
LH20-10A15
+15V/650mA
-15V/650mA
83
880
880
LH20-10C0505-05
--
Output Power
20W
5V/2500mA
±5V/500mA
74
11200
4480
LH20-10C0512-04
5V/2000mA
±12V/400mA
75
16000
1600
LH20-10C0515-03
5V/2000mA
±15V/300mA
76
13520
370
LH20-10C0524-02
5V/2000mA
±24V/200mA
77
11200
370
LH20-10D0512-06
5V/2500mA
12V/600mA
75
32400
3250
LH20-10D0515-05
5V/2500mA
15V/500mA
76
28000
1980
LH20-10D0524-03
5V/2500mA
24V/300mA
77
28000
720
LH25-10B03
13.53W
3.3V/4100mA
--
74
48000
--
LH25-10B05
20.5W
5V/4100mA
--
79
12240
--
LH25-10B09
9V/2500mA
--
81
5600
--
LH25-10B12
12V/2100mA
--
83
5400
--
15V/1600mA
--
84
2400
--
LH25-10B24
24V/1100mA
--
85
1440
--
LH25-10B48
48V/500mA
--
87
500
--
LH25-10B15
25W
Note: *About LH20-10AXX, use both positive and negative output as sampling feedback; and all others use Vo1 as sampling feedback.
2015.08.24-B/3
Page 1 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
AC input
85
--
264
VAC
DC input
100
--
370
VDC
Hz
47
--
63
115VAC
--
--
0.6
230VAC
--
--
0.34
115VAC
--
16
--
230VAC
--
30
--
Input frequency
Input current
Inrush current
Unit
A
Leakage current
0.3mA RMS typ./230VAC/50Hz
Recommended External Input
Fuse(Special package series include fuse)
3.15A/250V, slow fusing
Hot Plug
Unavailable
Output Specifications
Item
Operating Conditions
Output Voltage Accuracy
Main circuit
Line Regulation
Full load
10%-100%
load
Load Regulation
Min.
Typ.
Max.
--
±2
--
Main circuit
--
±0.5
--
Auxiliary circuit
--
±1.5
--
Single output
--
±1
--
Dual output(balanced load)
--
±2
--
Isolated triple output
(balanced load)
Main circuit
--
±3
--
Auxiliary circuit
--
±5
--
Isolated and separated twin
output (balanced load)
Main circuit
--
±3
--
Auxiliary circuit
Unit
%
--
±5
--
Ripple & Noise*
20MHz bandwidth (peak-peak value)
--
50
100
mV
Temperature Coefficient
Main circuit
--
±0.02
--
%/°C
Short Circuit Protection
Continuous, self-recovery
≥110%Io self-recovery
Over-current Protection
Over-voltage Protection
Main circuit
3.3 / 5VDC Output
≤7.5VDC
9VDC Output
≤13VDC
12 /15VDC Output
≤20VDC
24VDC Output
≤30VDC
48VDC Output
Min. Load
Hold-up Time
≤60VDC
Single output models
0
--
--
Dual output models (balanced load)
10
--
--
Isolated and separated twin output (balanced load)
10
--
--
Isolated triple output (balanced load)
10
--
--
115VAC input
--
15
--
230VAC input
--
80
--
%
ms
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.
General Specifications
Item
Isolation Voltage
Input-output
Operating Temperature
Storage Temperature
Storage Humidity
Operating Conditions
Min.
Test time: 1min
3000
Typ.
--
--
LH20-10A/C/D series
-25
--
+70
LH20(25)-10B series
-40
--
+70
LH20-10A/C/D series
-25
--
+85
LH20(25)-10B series
-40
--
+85
--
--
95
2015.08.24-B/3
Max.
Unit
VAC
°C
%RH
Page 2 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
Wave-soldering
Welding Temperature
260±5℃; time:5~10s
Manual-welding
360±10℃; time:3~5s
Switching Frequency
Power Derating
--
65
--
-25℃~-10℃(LH20-10A/C/D Series)
2.0
--
--
-40℃~-10℃(LH20(25)-10B Series)
2.0
--
--
+50℃~+70℃(LH25-10B Series)
3.0
--
--
4.0
--
--
+55℃~+70℃ (LH20-10A/B/C/D Series)
Safety Standard
IEC60950/EN60950/UL60950
Safety Certification
IEC60950/EN60950/UL60950
Safety Class
CLASS I
kHz
MIL-HDBK-217F@25°C > 300,000 h
MTBF
Physical Specifications
Casing Material
Dimension
Weight
Black flame-retardant and heat-resistant plastic (UL94-V0)
Horizontal packageg
70.00x48.00x23.50mm
A2 chassis mounting
96.10x54.00x32.00mm
A3 chassis mounting
99.00x54.00x32.00mm
A4 Din-Rail mountin
96.10x54.00x36.60mm
Horizontal package/A2 chassis mounting/
A3 chassis mounting/A4 Din-Rail mounting
120g/170g /170g /210g (Typ.)
Cooling method
Free convection
EMC Specifications
EMI
EMS
CE
CISPR22/EN55022, CLASS B
RE
CISPR22/EN55022, CLASS B
ESD
IEC/EN61000-4-2
±6KV/±8KV
Perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
IEC/EN61000-4-4
±2KV
perf. Criteria B
IEC/EN61000-4-4
±4KV (See Fig. 5 for recommended circuit)
perf. Criteria B
IEC/EN61000-4-5
±1KV/±2KV
perf. Criteria B
IEC/EN61000-4-5
±2KV/4KV (See Fig. 5 for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
PFM
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-8
10A/m
perf. Criteria A
EFT
Surge
EMS
IEC/EN61000-4-11
0%-70%
perf. Criteria B
Te mperature Der ating C ur ve
10 0
70
LH20-10A/B/C/D se rie s
LH20(25)-10B s eries
L H 25-10B s eries
L H 20-10A/C/D s eries
40
20
Input voltage: 85~264VAC
100~370VDC
-4 0-2 5 -1 0
50 55
Ambi ent Temper atur e(℃ )
70
Output Power Percent age(%)
Outpu t Power Percentage(%)
Product Characteristic Curve
Input Voltage Derating Cur ve
100
80
75
60
40
Ambient temperatu re: 25℃
20
85
100
100
120
240
340
In pu t Voltage
264 VAC
370 VDC
Note: ①When input 85~100VAC/240~264VAC/100~120VDC/340~370VDC, it need to be voltage derated on basis of temperature derating;
②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
2015.08.24-B/3
Page 3 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
Design Reference
1. Typical application circuit
F US E
A C(L)
NTC
AC(L)
+Vo
C1
C2
F US E
TV S
A C(L)
AC DC
MO V
- Vo
Fig. 1: LH20(25)-10B series (Single Output)Typical application circuit
F USE
NTC
+
AC(L)
M OV
AC(N)
ACDC
A C(N)
C1
C 2 TV S1
RL
AC(L)
NTC
+
Vo1
AC(L)
C 4 TV S2
RL
C1
C 2 TV S1
RL
C3
C 4 TV S2
RL
C5
C 6 TV S3
RL
-
ACDC
A C(N)
AC(N)
+
Vo2
C2(µF)
330
330
220
220
220
220
470
120
68
330
330
330
330
330
330
330
330
330
330
330
330
120
68
F USE
MO V
+Vo2
C om
C3
C 4 TV S2
RL
-Vo2
Fig. 3: LH20-10D series (Isolate Twin Output) typical application circuit
Model
LH20-10B03
LH20-10B05
LH20-10B09
LH20-10B12
LH20-10B15
LH20-10B24
LH20-10A05
LH20-10A12
LH20-10A15
LH20-10C0505-05
LH20-10C0512-04
LH20-10C0515-03
LH20-10C0524-02
LH20-10D0512-06
LH20-10D0515-05
LH20-10D0524-03
LH25-10B03
LH25-10B05
LH25-10B09
LH25-10B12
LH25-10B15
LH25-10B24
LH25-10B48
C3
Fig. 2: LH20-10A series (Dual Output) typical application circuit
Vo1
-
-
RL
AC DC
A C(N) C om
A C(N )
- Vo
AC(L)
C 1 C 2 TV S1
+Vo
A C(L)
MO V
RL
A C(N)
A C(N )
NTC
C4(µF)
470
120
68
120
120
120
47
220
220
120
Fig. 4: LH20-10C series (Triple Output) typical application circuit
C6(µF)
120
120
120
47
TVS1
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ64A
TVS2
TVS3
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ20A
SMBJ20A
SMBJ30A
SMBJ7.0A
SMBJ20A
SMBJ20A
SMBJ30A
Note:
Note: Output filtering capacitors C2, C4, C6 are electrolytic capacitors, it is recommended to use high frequency and low impedance electrolytic capacitor.
For capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor withstand voltage derating should be 80% or above. C1,C3, C5
are ceramic capacitors, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails. External input
NTC is recommended to use 5D-9. External input MOV model is recommended to use S14K300.
2015.08.24-B/3
Page 4 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
2. EMC solution-recommended circuit
Can u se M OR NSUN ' s FC-LX1 D
FUSE
LDM
LCM
AC( L)
AC( L)
+Vo
C1
C2
CY1
TVS1
RL
+
ACDC
MOV1 CX
CY2
-Vo
AC( N)
AC( N)
Fig 5: EMC Recommended circuit with higher requirements
Element
model
MOV1
Recommended value
S14K300
CY1 , CY2
1000pF/400VAC
CX
0.1μF/275VAC
LCM
10mH, recommended to use MORNSUN’s FL2D-Z5-103
LDM
4.7μH/2A
FC-LX1D
2KV/4KV EMC filter
FUSE
3.15A/250V slow fusing, necessary
3. Application of Trim and calculation of Trim resistance
+Vot
+Vot
Calculation formula of Trim resistance:
R1
V ref
R2
RT
R1
R3
Trim
V ref
RT
R3
0V
Trim up
Trim down
aR 2
R 2 -a
-R 3
down : R T =
aR 1
R 1 -a
-R 3
Trim
R2
0V
up: R T =
Vref
R1
RVotresistance
T is Trim
Vref
a is a self-defined parameter, with
Vot- Vref
no real meaning.
a=
R2
Vref
a=
Applied circuits of Trim (Part in broken line is the interior of models):
Vout
R1(KΩ)
R2(KΩ)
R3(KΩ)
Vref(V)
3.3V
3.3
1.98
1
1.24
5V
3.3
3.3
1
2.5
9V
7.5
2.87
1
2.5
12V
3.83
1
1
2.5
15V
7.5
1.5
1
2.5
24V
8.66
1
1
2.5
48V
68
3.73
1
2.5
Vot(V)
Output voltage
after regulation,
variation ≤ ±10%
4. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
2015.08.24-B/3
Page 5 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
Dimensions and Recommended Layout
LHXXA2 Dimensions
2015.08.24-B/3
Page 6 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
LHXXA3 Dimensions
LHXXA4 Dimensions
2015.08.24-B/3
Page 7 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LH20(25) Series
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing
bag number of Horizontal package : 58220006, the Packing bag number of A2/A3/A4 package:58220010;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal
4.
5.
6.
7.
input voltage and rated output load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
We can provide product customization service;
Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.08.24-B/3
Page 8 of 8
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation