Murata NMR Isolated 1w single output dc/dc converter Datasheet

NMR Series
www.murata-ps.com
Isolated 1W Single Output DC/DC Converters
FEATURES
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
NMR118C
NMR119C
NMR120C
5
5
5
12
12
12
24
24
24
5
12
15
5
12
15
5
12
15
200
83
67
200
83
67
200
83
67
„
Short circuit protection option
„
UL 60950 recognised
„
1kVDC isolation ‘Hi Pot Test’
„
Wide temperature performance at full
1 watt load, –40°C to 85°C
„
Industry standard pinout
NMR100PC
5
5
„
5V, 12V & 24V input
„
5V, 12V & 15V output
„
Fully encapsulated with toroidal magnetics
„
Custom solutions available
„
No electrolytic or tantalum capacitors
290
12 14
6
10
260
6.9 7.7 4.6 10
253
6.5 7.5 4.3 10
121 12.5 13.4 5.3 10
110
6.9 7.7 5
10
110
6.5 7.5 4
10
60
6.8 10
8
15
53
2.8 4
7
15
52
2.5 3.5 8
15
Short Circuit Protection Option
200
255
10 12 10 25
%
pF
69
77
79
69
76
76
70
78
80
74
MIL. Tel.
kHrs
28 1847
33 981
40 667
36 1485
58 869
56 613
61 1253
98 784
122 566
76.5
22
3095 61060
Recommended
Alternative
NMR112C
NMR113C
NMR114C
15
15
15
5
12
15
200
83
67
93
85
84
8.1
3.3
2.8
10
4
3.5
14
12
14
20
15
20
69
77
78
27
58
67
2110
1790
1560
MER1S1505SC
MER1S1512SC
MER1S1515SC
INPUT CHARACTERISTICS
Parameter
DESCRIPTION
The NMR series of industrial temperature range
DC/DC converters are the standard building
blocks for on-board distributed power systems.
They are ideally suited for providing single rail
supplies on primarily digital boards with the added
benefit of galvanic isolation to reduce switching
noise. Surface mount technology and advanced
packaging materials produce rugged reliable
performance over an extended temperature range
from -40ºC to 85ºC. For the NMR100PC protection
is continuous and auto-resetting on removal of the
short circuit.
%
mV p-p
Typ. Max. Typ. Max.
MTTF1
mA
Efficiency
(Min)
Efficiency
(Typ)
Isolation
Capacitance
mA
Ripple &
Noise3
V
Load
Regulation
Input
Current at
Rated Load
V
Order Code
Nominal Input
Voltage
Output
Voltage
Output Current
SELECTION GUIDE
Voltage range
Input short circuit current
Input reflected ripple
current
Conditions
Min.
Typ.
Max.
Units
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 15V input types
Continuous operation, 24V input types
Short circuit variants
Short circuit types
5V & 12V input types
15V & 24V input types
4.5
10.8
13.5
21.6
5
12
15
24
95
2
1.6
5
5.5
13.2
16.5
26.4
V
15
2
10
mA p-p
Typ.
Max.
Units
1.0
W
1.15
1.0
1.2
1.2
%/%
Typ.
Max.
Units
mA
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power2
Voltage Set Point Accuracy
TA=-40°C to 85°C, See derating graph
See tolerance envelope
High VIN to low VIN ; Short circuit types
High VIN to low VIN ; All other output types
Line regulation
Min.
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation voltage
Resistance
Flash tested for 1 second
Viso=1000VDC
1000
10
VDC
GΩ
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, NMR100C, NMR101C, NMR102C
Input voltage VIN, NMR106C, NMR107C, NMR108C
Input voltage VIN, NMR112C, NMR113C, NMR114C
Input voltage VIN, NMR118C, NMR119C, NMR120C
For full details go to
www.murata-ps.com/rohs
260°C
7V
15V
18V
28V
1. Calculated using MIL-HDBK-217 FN2 and Telcordia SR-332 calculation model with nominal input voltage at full load.
2. See derating graph.
3. See ripple & noise characterisation method.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com/support
KDC_NMR.F01 Page 1 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
5V input types
12V input types
15V input types
24V input types
Short circuit types
Min.
Typ.
Max.
110
160
90
80
97
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-50
Case Temperature above ambient
Cooling
5V output types
All other output types
Short circuit types
Free air convection
Typ.
Max.
Units
85
130
°C
33
28
18
TOLERANCE ENVELOPES
NMR118
NMR113, NMR 114, NMR119, NMR120
+7%
0%
-5%
10
75
50
25
Output Load Current (%)
100
Output Voltage
Output Voltage
+4%
+2%
VNOM
All other output types:
VNOM
-7.5%
50
75
Output Load Current (%)
100
Output Voltage
Output Voltage
+2.5%
25
-3%
10
75
50
25
Output Load Current (%)
100
Short circuit types:
+10%
+10%
10
+1%
VNOM
+5%
0%
VNOM
-6%
10
25
50
75
100
Output Load Current (%)
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
www.murata-ps.com/support
KDC_NMR.F01 Page 2 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMR series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMR is recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMR series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
UL60950
The NMR series is recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum still air ambient temperature of 100°C as measured at any point
on the case of the unit (hotspot).
FUSING
The NMR Series of converters are not internally fused so to meet the requirements of UL an anti-surge input line fuse should always be used with ratings as defined below.
Input Voltage, 5V 0.5A
Input Voltage, 12V 0.25A
Input Voltage, 24V 0.12A
All fuses should be UL recognized, 125V rated.
File number E151252 applies.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering
systems.
For further information, please visit www.murata-ps.com/rohs
TEMPERATURE DERATING GRAPHS
All other types.
Output Power (W)
Output Power (W)
Short Circuit types.
85°C
1
Safe Operating Area
0
-40
100
50
0
Ambient Temperature (°C)
150
85°C
1
Safe Operating Area
120°C
0
-40
100
50
0
Ambient Temperature (°C)
150
www.murata-ps.com/support
KDC_NMR.F01 Page 3 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
EFFICIENCY VS LOAD
NMR100C
NMR101C
NMR102
NMR106C
NMR107C
NMR108C
www.murata-ps.com/support
KDC_NMR.F01 Page 4 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
EFFICIENCY VS LOAD
NMR118C
NMR119C
NMR120C
NMR100PC
90
80
70
Efficiency (%)
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata-ps.com/support
KDC_NMR.F01 Page 5 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Typical Start-Up Wave Form
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
Start-up time
μs
2301
5570
8289
783
4770
4850
NMR112C
NMR113C
NMR114C
NMR118C
NMR119C
NMR120C
NMR100PC
Start-up time
μs
744
1908
6620
671
5335
6370
360
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com/support
KDC_NMR.F01 Page 6 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
NMR112C
NMR113C
NMR114C
NMR118C
NMR119C
NMR120C
NMR100PC
L, μH
10
47
47
10
47
47
10
47
47
10
47
47
22
Inductor
SMD
82103C
82473C
82473C
82103C
82473C
82473C
82103C
82473C
82473C
82103C
82473C
82473C
82223C
C
Load
DC
Through Hole
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
11R223C
Capacitor
C, μF
4.7
1
1
4.7
1
1
4.7
1
1
4.7
1
1
1
www.murata-ps.com/support
KDC_NMR.F01 Page 7 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The following filter circuit and filter table shows the input filters typically required to meet EN 55022 Curve B, Quasi-Peak EMC limit, as shown in the following plots. The
following plots show positive and negative quasi peak and CISPR22 Average Limit B (pink line) and Quasi Peak Limit B (green line) adherence limits.
L
DC
C
DC
C
Ceramic capacitor
Inductor
Capacitor
Part Number
L, μH
SMD
Through Hole
C, μF
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
NMR118C
NMR119C
NMR120C
NMR100PC
10
82103C
13R103C
10
NMR100C
NMR101C
NMR102C
NMR106C
www.murata-ps.com/support
KDC_NMR.F01 Page 8 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
EMC FILTERING AND SPECTRA
NMR107C
NMR108C
NMR118C
NMR119C
NMR120C
NMR100PC
80
70
60
dBuV
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata-ps.com/support
KDC_NMR.F01 Page 9 of 10
NMR Series
Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS - 7 PIN SIP
7 Pin SIP Package
19.50±0.25 [0.768±0.010]
Pin
Function
1
2
4
6
+VIN
-VIN
-VOUT
+VOUT
6.00±0.25 [0.236±0.010]
TUBE OUTLINE DIMENSIONS
9.3 [0.366]
10.00±0.25 [0.394±0.010]
S
4.10±0.5 [0.161±0.020]
0.50±0.05 [0.020±0.002]
5.08 [0.200]
12.43 [0.489]
0.25±0.05 [0.010±0.002]
18.0 [0.709]
1
(1.13 [0.044])
(1.93 [0.076])
2
4
6
2.54 [0.100]
12.70 [0.500]
5.0 [0.197]
Weight: 2.1g (C) 1.9g (PC)
All dimensions in mm (inches) Controlling dimension is mm.
All pins on a 2.54 (0.100) pitch and within ±0.1 (0.004) of true position from pin 1 at seating plane ‘S’
Unless otherwise specified all dimensions in mm [inches] ±0.55mm [0.022].
Tube Length : 520mm [20.472] ±2.0 [0.079].
Tube quantity: 35
RECOMMENDED FOOTPRINT DETAILS
2.54 [0.100]
x4 HOLES
Ø 0.045
0.039
Ø 1.15
1.00
[
]
2.54 [0.100]
All dimensions in mm (inches) Controlling dimension is mm.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2016 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NMR.F01 Page 10 of 10
Similar pages