CANDD NPH15S2405I Isolated 15w single output dc-dc converter Datasheet

NPH15S SERIES
Isolated 15W Single Output DC-DC Converters
SELECTION GUIDE
Nominal
Input Voltage
Output
Voltage
Output
Current
(V)
24
24
24
24
48
48
48
48
(V)
3.4
5.1
12.1
15.1
3.4
5.1
12.1
15.1
(mA)
4.4
3.0
1.3
1.0
4.4
3.0
1.3
1.0
Order Code1
NPH15S2403i
NPH15S2405i
NPH15S2412i
NPH15S2415i
NPH15S4803i
NPH15S4805i
NPH15S4812i
NPH15S4815i
FEATURES
■ High Efficiency to 89%
■ Power Density up to 2.4W/cm3
(39W/in3 )
Current
Limit
(A)Min
7.5
5.0
2.5
2.0
7.5
5.0
2.5
2.0
Efficiency
(A)Max
11.0
7.5
3.7
3.0
11.0
7.5
3.7
3.0
(%)
81
84
86
87
83
85
88
89
INPUT CHARACTERISTICS
Parameter
Conditions
Voltage Range
Continuous operation, 24V input types
Continuous operation, 48V input types
MIN
NOM
MAX
Units
18
36
24
48
36
75
V
■ 1.5kV Input to Output Isolation
■ Industry Standard Pinout
OUTPUT CHARACTERISTICS
■ UL 1950 Recognised
Parameter
Conditions
MAX
Units
Voltage Set
Point Error
50% load
0.5
%
Overall
Voltage Error
Case temperature –40°C to 110°C
Load 0% - 100%
Input specified range
2.5
%
250
ppm°C
■ Non Latching Current Limit
■ Constant 350kHz Frequency
■ Versatile Control Options
■ Continuous Rating to 30W
at 40°C Without Heatsink
■ Operation to Zero Load
■ Protected Against Load Faults
■ Internal Over Temperature Protection
■ Uses No Electrolytic Capacitors
■ UL 94V-0 Package Materials
DESCRIPTION
The NPH15S series of DC-DC Converters
combines ease of application with versatility.
The pin pattern is based on the popular
industry standard, but two additional pins
may optionally be fitted to provide a variety
of features not commonly found on units of
this type. High efficiency enables full rating to
be achieved in a small package without
heatsinking, and a high surge capability will
provide for start-up and transient loads, whilst
being thermally protected against sustained
overload. Overload protection of the
“constant current” type ensures start-up
into complex load conditions. The copper
case achieves efficient heat transfer and
screening. The product range has been
recognised by Underwriters Laboratory (UL)
to UL 1950 for operational insulation, file
number E179522 applies.
Temperature Coefficient
of Output Voltage
(slope)
Deviation of
Output Voltage
Line Regulation
Load Regulation
Ripple
MIN
Temperature MIN-MAX
TYP
0.5
Operating voltage range, 50% load
0% - 100% rated load2
rms
1
%
0.1
0.5
%
%
mV
MAX
Units
70
CONTROL CHARACTERISTICS
Parameter
Conditions
Voltage Trimming
Range
Remote Switch Input3
At rated load,
Trim control at either output
Not operating
(voltage relative
to input negative)
Start Delay
Synchronisation3
Switching Frequency
MIN
TYP
±10
Operating, open circuit voltage
Time from application of valid input
voltage to output being in specification
Specified drive signal
%
-15
0
1.5
9
10
11
320
330
V
25
50
mS
350
440
395
kHz
kHz
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output Voltage
Output trim control
Synchronisation/shutdown control
–0.5V to 40V4
–0.5V to 80V4
–0.3V to regulated voltage
–1V to +30V
±15V relative to input return
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation Voltage
Resistance
Flash tested for 1 second
Viso=500VDC
MIN
TYP
1500
1
4000
MAX
Units
VDC
GΩ
1 If optional pins ADJ and SS are required (as indicated in the pin connections diagram) prefix the ending “i” with
an E when ordering, e.g. NPH15S4803Ei.
www.cdpoweronline.com
2 A minimum load of 10% of rating is recommended for typical applications.
3 Optional where fitted.
4 Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NPH15S SERIES
Isolated 15W Single Output DC-DC Converters
ENVIRONMENTAL
Parameter
Conditions
MIN
Case Temperature
Storage
Relative Humidity
Thermal Protection
Full load
Absolute MAX internal temperature
Non condensing 85°C
Operates at case temperature
–40
–40
Power (W)
40
50
60
70
15.0
15.0
13.7
11.7
80
85
90
9.8
8.8
7.8
Output Power (W)
Temperature (°C)
20
NPH15S4803
NPH15S4805
NPH15S4812
NPH15S4815
2403
10
0
-40
110°C
12
15
19
21
13
16
23
25
-20
0
20
40
60
W
100 120
4815
30
W
80
Ambient Temperature (°C)
35
Units
Output Power (W)
NPH15S2415
2405
15
5
Case Temperature
NPH15S2412
2415
25
MAX power rating with case temperature maintained by external means
(eg forced air cooling)
105°C
16
19
22
24
17
20
26
28
2412
30
Power (W)
NPH15S2405
°C
°C
%
°C
35
Temperature (°C)
NPH15S2403
Units
110
125
85
THERMAL PERFORMANCE
UL 1950 recognition MAX permissible loads for a given ambient temperature for any NPH15S model
100°C
19
22
25
26
20
23
28
30
MAX
110
THERMAL CHARACTERISTICS
Part Number
TYP
4812
25
20
4805
15
4803
10
5
0
-40
-20
0
20
40
60
80
Ambient Temperature (°C)
100 120
MECHANICAL DIMENSIONS
1.97 (50.00)
0.09 (2.34)
BOTTOM VIEW
SS
0.20
(5.08)
0.98
(25.00)
+V OUT
+VIN
0.20
(5.08)
0.80
20.32
-VIN
ADJ
0.39
(9.96)
0V
0.20 (5.08)
0.4
(10.00)
0.18 (4.50)
0.15 (3.70)
0.58
(14.84)
0.40 (1.04)
Ø
0.04 (0.90)
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
For information and instructions on use, please consult the NPH SERIES
APPLICATION NOTES.
© C&D Technologies (NCL) Limited 2002
Weight: 36g
All dimensions in Inches(mm) ± 0.01(0.25)
All pins on a 0.10(2.54) pitch and within ±0.01(0.25) of true position
Case connected to 0V pin
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax: +44 (0)1908 617545
email: [email protected]
NDC NPH15S.5
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.cdpoweronline.com
0.80
(20.32)
www.cdpoweronline.com
C&D Technologies Inc.
3400 E Britannia Drive, Tucson,
Arizona 85706, USA
Tel: +1 (800) 547-2537
Fax: +1 (520) 741-4598
email: [email protected]
Similar pages