ETC2 OM1915NKM Hermetic to-3 fixed voltage negative regulators approved to desc drawing Datasheet

OM1905NKM OM1915NKM
OM1912NKM
HERMETIC TO-3 FIXED VOLTAGE NEGATIVE
REGULATORS APPROVED TO DESC DRAWINGS
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Negative Regulators In Hermetic
JEDEC TO-3 Package
FEATURES
•
•
•
•
•
•
Output Voltages: -5V, -12V, -15V
Output Voltages Set Internally to ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Similar To Industry Standards 7905, 7912, 7915
Hi-Rel Screening Available
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed TO-3
metal package . All protective features are designed into the circuit, including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These
units are ideally suited for Military applications where a hermetically sealed package
is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8874601 YX
5962-8874701 YX
5962-8874801 YX
4 11 R0
3.3 - 87
Omnirel Part Number
OM1905NKM
OM1912NKM
OM1915NKM
3.3
OM1905NKM - OM1915NKM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6W
Thermal Resistance
qJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
aa
qJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
ELECTRICAL CHARACTERISTICS -5 Volt
VIN = -10V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Output Voltage
VOUT
TA = 25°C
-4.95
-5.05
V
-4.85
-5.15
V
VIN = -7.5V to -20V
•
Unit
IO = 5mA to 1.0 A, P< 20W
Line Regulation
VRLINE
VIN = -7.5V to -20V
(Note 1)
(Note 4)
Load Regulation
12
mV
•
25
mV
5
mV
•
12
mV
20
mV
•
25
mV
15
mV
•
30
mV
VIN = -8.0V to -12V
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
2.5
mA
3.0
mA
VIN = -7.0V to -20V
•
•
0.4
mA
IO = 5mA to 1000mA
•
0.4
mA
•
2.5
V
3.3
A
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
•
(Note 2)
3.3
Ripple Rejection
Output Noise Voltage
1.5
DVIN
f =120 Hz, DVIN = -10V
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
•
1.2
A
2.8
A
63
dB
60
dB
40
(Note 3)
µV/V
RMS
Long Term Stability
DVOUT
(Note 3)
Dt
TA = 25°C, t = 1000 hrs.
75
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 88
OM1905NKM - OM1915NKM
ELECTRICAL CHARACTERISTICS -12 Volt
VIN = -19V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Output Voltage
VOUT
TA = 25°C
-11.88
-12.12
V
-11.64
-12.36
V
•
VIN = -14.5V to -27V
Unit
IO = 5mA to 1.0 A, PD < 20W
Line Regulation
VRLINE
VIN = -14.5V to -27V
(Note 1)
(Note 4)
20
mV
•
50
mV
10
mV
•
30
mV
32
mV
•
60
mV
16
mV
•
30
mV
VIN = -16V to -22V
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
3.5
mA
4.0
mA
VIN = -14.5V to -27V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
1.8
V
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C, IO = 5mA to 1A
Short Circuit Current
IDS
VIN = -35V
DVIN
f =120 Hz, DVIN = -10V
1.5
•
(Note 2)
Ripple Rejection
3.3
A
1.2
A
2.8
•
dB
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
Dt
Output Noise Voltage
A
56
53
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.3
MECHANICAL OUTLINE
1.197
1.53
REF.
1.177
0.875
MAX.
0.675
0.655
0.188 R.
MAX.
0.135
MAX.
2
0.450
0.250
1
0.312
MIN.
SEATING
PLANE
0.043
0.038
0.225
0.205
0.161
0.151
2 PLCS.
3.3 - 89
0.525 R.
MAX.
0.440
0.420
Pin Connection
Pin 1: Ground
Pin 2: Output
Case: Input
OM1905NKM - OM1915NKM
ELECTRICAL CHARACTERISTICS -15 Volt
VIN = -23V, Io = 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Output Voltage
VOUT
TA = 25°C
-14.85
-15.15
V
-14.55
-15.45
V
•
VIN = -17.5V to -30V
Unit
IO = 5 mA to 1.0 A, PD < 20 W
Line Regulation
VRLINE
VIN = -17.5V to -30V
(Note 1)
(Note 4)
25
mV
•
50
mV
15
mV
•
25
mV
35
mV
•
75
mV
21
mV
•
45
mV
VIN = -20V to -26V
Load Regulation
VRLOAD
IO = 5mA to 1.5 Amp
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
ISCD
Standby Current Drain
DISCD
Change With Line
(Line)
Standby Current Drain
DISCD
Change With Load
(Load)
6.0
mA
6.5
mA
VIN = -17.5V to -30V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
2.5
V
Dropout Voltage
VDO
DVOUT = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = -35V
DVIN
f =120 Hz, DVIN = -10V
1.5
•
(Note 2)
Ripple Rejection
3.3
A
1.2
A
2.8
•
dB
DVOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DVOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
Dt
Output Noise Voltage
A
53
50
dB
µV/V
(Note 3)
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = -35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT CURRENT
RIPPLE REJECTION
DROPOUT VOLTAGE
2.5
3.5
3
Tj =
100
2
80
IOUT = 1A
VOUT = 5V
2
Tj = 25°C
1.5
1
Tj = 150°C
0.5
0
5
10
15
IOUT = 500mA
1
IOUT = 0A
0.5
DVOUT = 100MV
DVOUT = 100mV
0
1.5
20
25
30
35
0
-75 -50 -25
0
25 50 75 100 125 150
Ripple Rejection (dB)
Output Current (A)
2.5
Output Current (A)
3.3
60
40
VIN - V = 8VDC +3.5Vrms
IOUT = 1A
Tj = 25°C
20
0
10
100
1k
10k
205 Crawford
MA 01453
USA (508)
534-5776 FAX (508) 537-4246Frequency (Hz)
Input To Output Differential
(V) Street, Leominster,
Junction
Temperature
(°C)
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246