AD 3B18

Wide Bandwidth Strain Gage Input
3B18
FEATURES
Wideband (20 kHz) single-channel signal conditioning
module.
Module Bandwidth is user-selectable between 20 kHz and
100Hz, with user-supplied filter caps installed in the optional
AC1310 ranging card.
Interfaces, amplifies, and filters signals from balanced 4-arm
full-bridge strain-gage bridges.
Module provides simultaneous precision voltage and
current outputs.
Module circuitry can withstand 130v rms at the input screwterminals
All 3B18 series modules are mix-and-match and Hot
Swappable
APPLICATIONS
Industrial signal conditioning
Industrial signal isolation
Industrial signal filtering
PRODUCT OVERVIEW
The 3B Series of Signal Conditioning I/o Subsystems provide a
low-cost, versatile method of transferring analog transducer
signals to a data acquisition, monitoring or control system
without the inherent noise, non-linearity, drift and extraneous
voltages. The modules are designed to directly accept analog
signals from Thermocouples, RTD’s, AC and DC Strain Gages,
Torque Transducers, Frequency Transducers, LVDTs, millivolt
or process current signals. The modules amplify, isolate,
linearize and convert the transducer output signals to
standardized analog inputs for high-level analog I/O
subsystems. The 3B Series Subsystem consists of a 10” relay
rack with universal mounting backplane and a family of plug-in
(up to 16 per rack) input and output signal conditioning
modules.
Eight and four channel backplanes are also available. Each
backplane incorporates screw terminals for sensor inputs and
current outputs and a 26-pin connector for high-level singleended voltage outputs to the user’s equipment.
The input modules feature complete signal conditioning
circuitry optimized for specific sensors or analog signals and
provide two simultaneous high-level analog outputs: 0 to +10V
(or +10V) and 4-20 mA (or 0-20 mA).
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 3B18 Functional Block Diagram
Output modules accept 0 to +10V (or +10V) single-ended
signals and provide an isolated 4-20 mA (or 0-20 mA) process
signal. All modules feature a universal pin-out and may be
readily hot-swapped under full power and interchanged without
disrupting field wiring.
The Analog Devices 3B Series Signal Conditioning Subsystem is
designed to easily handle signal conditioning problems in
measurement and control applications. Some typical uses are in
microcomputer-based data acquisition systems, programmable
controllers, analog recorders, dedicated control systems, and any
other applications where monitoring of temperature, pressure,
flow and analog signals are required. Since each input module
features two simultaneous outputs, the voltage output can be
used to provide an input to a microprocessor-based data
acquisition or control system while the current output can be
used for analog transmission, operator interface, or an analog
backup system.
Each input module is a single-channel signal conditioner which
plugs into a socket on the backplane and accepts its signal from
the input screw terminals. All input modules provide input
protection, amplification and filtering of the input signal,
accuracy of +0.1%, low drift of +1 uV/oC (low-level input
modules), and feature two high-level analog outputs that are
compatible with most process instrumentation. The isolated
input modules also provide +1500 V peak isolation.
The choice of a specific 3B module depends upon the type of
input signal. Input modules are available to accept millivolt, volt,
process current, thermocouple, RTD, AC and DC strain gage,
frequency and LVDT inputs. The voltage output of each module
is available from the system I/O connector while the current
output is available on the output screw terminals.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable.
However, no responsibility is assumed by Analog Devices for its use, nor for any
infringements of patents or other rights of third parties that may result from its use.
Specifications subject to change without notice. No license is granted by implication
or otherwise under any patent or patent rights of Analog Devices. Trademarks and
registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
www.analog.com
Tel: 781.329.4700
Fax: 781.326.8703
© 2004 Analog Devices, Inc. All rights reserved.
3B18
GENERAL DESCRIPTION
both voltage and current outputs.
The 3B18 is a wideband (20kHz) single-channel signal
conditioning module which interfaces, amplifies, and filters
signals from balanced 4-arm full-bridge strain-gage bridges
with a resistance from 100Ω to 10 kΩ, providing simultaneous
precision voltage and current outputs. The module provides two
user-selectable (via front-panel switches) bridge excitation
voltages: +10 V for bridges with a load impedance down to
300W or +3.33V for 120W bridges or others below 300W.
Module bandwidth is also user-selectable between 20 kHz and
100 Hz, with user-supplied filter capacitors installed in the
optional AC1310 ranging card. The 3B18 protects the computer
side from damage due to field-side over-voltage faults up to
130V rms. In addition, the current output withstands 130V rms
without damage and interfaces user equipment through screw
terminals located on the 3B Series backplane. The 3B18 is a
plug-in, mix-and-match, hot-swappable module which is easily
field calibrated via front-panel zero and span adjustments for
3B Series Custom-Ranging Program – Externallyprogrammable Model 3B18-00, enables the user to configure a
special input range by using the optional plug-on AC1310
ranging card, which houses user-supplied resistors to determine
zero and span. To facilitate selecting resistors, a Windows
program, 3B-CUSTOM, calculates resistor values based on the
user-desired input/output ranges.
A chopper-stabilized low-drift (+1uV/oC) input amplifier
assures long-term stability. For user convenience, the zero and
span can be factory configured to meet custom range needs
(Model 3B18-CUSTOM) or can be externally programmed
(Model 3B18-00) via user supplied resistors inserted in the
optional AC1310 plug-on ranging card.
.
.
Figure 2
Rev. 0 | Page 2 of 8
3B18
3B18 Models Available
Model
Input
Bridge
Input
Range
Excitation1
Sensitivity
Output
Ranges
3B18-00
Full
Bridge
Externally
Programmable3
+10.0 V or +3.33 V
Externally
Programmable3
-10 V to +10 V &
0 mA to 20 mA
3B18-01
Full
Bridge
-30 mV to +30 mV
+10.0 V or +3.33 V
3 mV/V @ 10 Vexc
-10 V to +10 V &
0 mA to 20 mA
3B18-02
Full
Bridge
-10 mV to +10 mV
+10.0 V or +3.33 V
3 mV/V @ 3.33 Vexc
-10 V to +10 V &
0 mA to 20 mA
3B18-Custom
Full Bridge
*
+10.0 V or +3.33 V
*
*
1
Output current range may be user programmed to 4 mA to 20 mA using jumper supplied.
Requires AC1310 ranging card.
* Custom Input/Output ranges are available. Refer to configuration guide.
2
3B18 Specifications
(typical @ +25°C and ±15 V dc, and +24 V dc Power)
Description
Model 3B18
Input Range
Standard Range
±30 mV (3 mV/V sensitivity @ Vexc = +10V)
±10 mV (3 mV/V sensitivity @ Vexc = +3.33 V)
Custom Ranges
±5 mV to ±500
Output Range
-10 V to +10 V
Voltage (RL > 2 KΩ)
Current (RL = 0 to 850Ω)
1
Maximum Current Output Span
4 mA to 20 mA or 0 mA to 20 mA
0 mA to 31 mA
Accuracy2
Initial @ +25°C
2
Nonlinearity
±0.1% Span
±0.01% Span
Stability vs. Temperature
Voltage Output
Zero
±3 µV/°C (RTI)
Span
±25 ppm of Reading/°C
Current Output3
Zero
±25 ppm of Span/°C
Span
±25 ppm of Reading/°C
Bridge Excitation
Voltage user-selectable
+10 V or +3.33 V
Voltage, tolerance
±2%
Voltage vs. Temperature
±0.0015%/°C
Bridge Resistance Range
Vexc= +10.0 V
300 Ωto 1 kΩ
Rev. 0 | Page 3 of 8
3B18
100 Ωto 10 kΩ
Vexc = +3.33 V
4
Zero and Span Adjustment Range
±5% of Span
Input Bias Current
+25 nA
Input Resistance
100 MΩ
Bandwidth, -3 dB
20 kHz
Output Rise Time, 10% to 90% Span
24µs
Common-Mode Voltage (CMV)
Input-to-Output, Continuous
±10 V peak, maximum
Transient
ANSI/IEEE C37.90.1- 1989
Common Mode Rejection (CMR)
1k
Source Imbalance, 50/60 Hz
100 dB
Input Protection, Signal and Excitation Voltage
Continuous
130 V rms maximum
Transient
ANSI/IEEE C37.90.1-1989
Voltage Output Protection
Continuous Short to Ground
Current Output Protection
130 V rms, continuous
Power Supply Voltages5
±15 V dc Supplies
Rated Operation
±(13.5 V dc to 16.5 V dc)
Current
+50 mA, -15 mA
Sensitivity
±0.01% span/V
+24 V dc Loop Supply
Rated Operation
+12 V dc to +30 V dc
Current
+27 mA @ lout = 20 mA
Sensitivity
±0.0002% span/V
Mechanical Dimensions
3.15" x 3.395" x 0.775"
(80.0 mm x 86.2 mm x 19.7 mm)
Environmental
Temperature Range
Rated Performance
-25°C to +85°C
Storage
-55°C to +85°C
Relative Humidity, 24 hours
0 to 95% @ +60°C non-condensing
RFI Susceptibility
±0.5% Span error @ 400 MHz, 5 Watt, 3 ft
1
For a 0 mA to 20 mA range, a typical minimum output current is 10 µA.
Includes the combined effects of repeatability, hysteresis, and nonlinearity.
With respect to the voltage output.
4
A wide range of custom zero suppression and span is available with the 3B18-00 model, using the AC1310 ranging card.
5
+24 V dc loop power is required for driving the current output at loads up to 850Ω. If a current output load of 400Ω or less is applied, +15 V dc is sufficient for loop power. If only
voltage output is used, loop power is not required.
2
3
Rev. 0 | Page 4 of 8
3B18
PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS
Figure 3 3B18 Input Field Connections
Table 1. Pin Function Descriptions—
Pin No.
1
2
3
4
Description
+EXC
HI
LO
-EXC
Figure 4 . Model 3B Series Module, with pin-out assignments.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human
body and test equipment and can discharge without detection. Although this product features proprietary ESD
protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges.
Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
Rev. 0 | Page 5 of 8
3B18
OUTLINE DIMENSIONS
Figure 5. Outline Dimensions
Rev. 0 | Page 6 of 8
3B18
NOTES
Rev. 0 | Page 7 of 8
3B18
NOTES
© 2004 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective companies.
D05091-0-9/04(0)
Rev. 0 | Page 8 of 8