POINN Y1112L

THE FLUORACTOR® Y1112L
FLUORESCENT LAMP STARTER SWITCH
Copyright © 1998, Power Innovations Limited, UK
●
V(BR) 1200 to 1500 V
●
IH > 175 mA
●
IGT < 2 mA
MARCH 1998 - REVISED MAY 1998
L PACKAGE
(TOP VIEW)
description
This product is intended for use as a T8/T12
fluorescent tube starter switch on 200-240 V a.c.
supplies with tube sizes up to 5 ft with leading
and lagging ballast circuits.
K
1
A
2
G
3
Pin 2 is in electrical contact with the heat slug.
MDXXAO
absolute maximum ratings at 25°C case temperature (unless otherwise noted)
RATING
SYMBOL
VALUE
Crest working off-state voltage (Full wave rectified 50 Hz a.c.)
VDWM
375
V
Peak reverse gate voltage
VRGM
6
V
IT
1.5
On-state current
— continuous
UNIT
— repetitive peak
ITRM
2
— non-repetitive peak
ITSM
10
Peak gate current
IGRM
0.5
A
Average gate power
PG(av)
0.3
W
°C
A
Operating case temperature range
TC
-5 to +85
Storage temperature range
Tstg
-10 to +110
°C
Lead temperature during soldering 1.6 mm from the case for 10 seconds
Tlead
230
°C
electrical characteristics at 25°C case temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
ID
Off-state current
VD = VDWM
VT
On-state voltage
IT = 2 A
V (BR)
Clamping voltage
I(BR) = 5 mA
Holding current
See application circuit
IH
IGTM
VGTM
Peak gate
trigger current
Peak gate
trigger voltage
MIN
Tj = 65°C
tp < 200 µs, 2% duty cycle
1200
TYP
MAX
UNIT
1
mA
3.1
V
1500
V
175
mA
VAA = 10 V
RL = 10 Ω
2
mA
VAA = 10 V
RL = 10 Ω
3
V
Fluoractor® is a Registered Trade Mark of Power Innovations Ltd
PRODUCT
INFORMATION
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.
1
THE FLUORACTOR® Y1112L
FLUORESCENT LAMP STARTER SWITCH
MARCH 1998 - REVISED MAY 1998
applications data
The conventional method of starting fluorescent tubes employs the use of an electromechanical canister. This
consists of a bimetallic strip which opens as it cools and in conjunction with the ballast inductor, provides the
tube striking voltage. However, the random nature of the pulsing results in repeated striking attempts and
degradation of both the tube and starter. The tube degradation is illustrated by its progressively blackening
ends and ultimately required tube replacement.
The Y1112L, “Fluoractor®”, has been specifically introduced for use in electronic starters. This unique device
offers the lighting industry an opportunity to develop electronic starters small enough to be retrofit
replacements for the established electromechanical canisters. Its double thyristor structure with integrated
zener clamp diode and current mirror provides the technology for a starter with enhanced features such as
controlled flicker free start up, automatic tube shutdown at end of tube life and reduced degradation of tube
ends leading to extended life. The increased functionality, lifetime and reliability of these starters has led in
some cases to them being embodied in the ballast itself, a development not feasible with the old
electromechanical canisters.
R1
150 kΩ
R6
330 kΩ
D1 to 4
(see Note 1)
ΤΗ2
R4
270 kΩ
Figure 1. Two terminal starter circuit
1: These rectifiers need to be voltage selected for VR ≥ V(BR)max + 150 V
PRODUCT
2
INFORMATION
Y1112L
K
R2
68 k Ω
R3
6.8 kΩ
NOTE
A
G
D5
D6
D8
R5
4.7 kΩ
D7
C1
100 µF
THE FLUORACTOR® Y1112L
FLUORESCENT LAMP STARTER SWITCH
MARCH 1998 - REVISED MAY 1998
MECHANICAL DATA
SOT-82
3-pin plastic single-in-line package
This single-in-line package consists of a circuit mounted on a lead frame and encapsulated within a plastic
compound. The compound will withstand soldering temperature with no deformation, and circuit performance
characteristics will remain stable when operated in high humidity conditions. Leads require no additional
cleaning or processing when used in soldered assembly.
SOT-82
2,7
2,4
7,8
7,4
10,8
10,5
Exposed
Heat Slug
2,54 typ
0,9
0,7
15,7 typ
1
2
3
0,75
0,49
2,2 typ
4,4 typ
1,2 typ
ALL LINEAR DIMENSIONS IN MILLIMETERS
NOTE:
contact with
with the
the heat
heat slug.
slug.
NOTE A: The
The centre
centre pin
pin is
is in
in electrical
electrical contact
PRODUCT
MDXXAQ
INFORMATION
3
THE FLUORACTOR® Y1112L
FLUORESCENT LAMP STARTER SWITCH
MARCH 1998 - REVISED MAY 1998
IMPORTANT NOTICE
Power Innovations Limited (PI) reserves the right to make changes to its products or to discontinue any
semiconductor product or service without notice, and advises its customers to verify, before placing orders, that the
information being relied on is current.
PI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with PI's standard warranty. Testing and other quality control techniques are utilized to the extent PI
deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except as mandated by government requirements.
PI accepts no liability for applications assistance, customer product design, software performance, or infringement
of patents or services described herein. Nor is any license, either express or implied, granted under any patent
right, copyright, design right, or other intellectual property right of PI covering or relating to any combination,
machine, or process in which such semiconductor products or services might be or are used.
PI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED, OR WARRANTED TO BE
SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS.
Copyright © 1998, Power Innovations Limited
PRODUCT
4
INFORMATION