The EasySYNC ES-R-2001B-M and ES-R-2101B-M are used to convert RS-232 signals to RS-422/RS485 signals. The converters provide instant connectivity to RS-422/RS-485 communication devices
for factory automation equipment, multi-drop data collection devices, barcode readers, time clocks,
scales, data entry terminals, PC to PC long distance communications (up to 1.3KM) and serial
communication in harsh environments.
This manual covers the following products: EasySYNC Ltd
ES-R-2001B-M
Unit 1, 2 Seaward Place, Centurion Business Park, Glasgow, G41 1HH, United Kingdom
ES-R-2101B-M
Tel.: +44 (0) 141 418 0181
Fax: + 44 (0) 141 418 0110
E-Mail (Support): [email protected]
Web: http://www.easysync.co.uk
Use of EasySYNC devices in life support and/or safety applications is entirely at the user’s risk, and the
user agrees to defend, indemnify and hold harmless EasySYNC from any and all damages, claims, suits
or expense resulting from such use.
Copyright © 2010 - 2011 EasySYNC Limited
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
1
Introduction ............................................................................................ 3
2
Specification ............................................................................................ 4
3
Features of the ES-R-2x01B-M ................................................................. 5
4
3.1
Optical Isolation & Surge Protection (ES-R-2101B-M only) ........................... 5
3.2
Power Supply ................................................................................................ 5
3.3
Enclosure ...................................................................................................... 5
3.4
Configuring for RS-422 and RS-485 Modes ................................................... 5
Hardware Installation .............................................................................. 6
4.1
General Notes and Warnings ......................................................................... 6
4.2
RS-232 DCE or DTE Pin Assignment .............................................................. 7
Table 1
4.3
RS-422 and RS-485 Mode Block Configuration .............................................. 7
Table 2
4.4
RS-422 and RS-485 configuration ........................................................... 7
Termination and Biasing Configuration ......................................................... 8
Table 3
5
Jumper settings for RS-232 DCE or DTE Pin Assignment ......................... 7
Termination and Biasing configuration.................................................... 8
Connector Pinout Information ................................................................. 9
5.1
RS-232 Signal Pin-outs of DB-9 Female (DCE) .............................................. 9
5.2
RS-232 Signal Pin-outs of DB-9 Female (DTE) .............................................. 9
5.3
RS-422 Signal Pin-out ................................................................................. 10
5.4
RS-485 Signal Pin-out (half duplex) ............................................................ 12
5.5
RS-485 Signal Pin-out (full duplex) ............................................................ 14
6
Contact Information ...............................................................................16
7
Legal Disclaimer .....................................................................................17
Appendix A - List of Figures and Tables ........................................................18
Appendix B - Revision History .......................................................................19
©2010 - 2011 EasySYNC Ltd.
2
ES-R-2x01B-M
1
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Introduction
The EasySYNC ES-R-2001B-M and ES-R-2101B-M are used to convert RS-232 signals to RS-422/RS-485
signals. The converters provide instant connectivity to RS-422/RS-485 communication devices for factory
automation equipment, multi-drop data collection devices, barcode readers, time clocks, scales, data
entry terminals, PC to PC long distance communications (up to 1.3KM) and serial communication in harsh
environments.
The ES-R-2001B-M and ES-R-2101B-M provide an industrial solution for applications requiring single
node or multi-drop communications over short or long distances.
In RS-485 half-duplex mode, the ES-R-2001B-M and ES-R-2101B-M also provide automatic data
transmit/receive control.
This user guide covers the following models:
RS-232 to RS-422/RS-485 Converter
(ES-R-2001B-M)
Opto-isolated RS-232 to RS-422/RS-485 Converter
(ES-R-2101B-M)
©2010 - 2011 EasySYNC Ltd.
3
ES-R-2x01B-M
2
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Specification
RS-232 to RS-422/RS-485 Converter (ES-R-2001B-M)
Converts RS-232 port to high speed RS-422 / RS-485 port
RS-232 port can be selected to DCE or DTE pin assignment
Data rate: 300 bps to 1M bps
RS-232 connector: One DB-9 female connector
RS-422 / RS-485 connector: One DB-9 male connector and one 5-pin terminal block
Auto transmit/receive control for 2-wire RS-485 half-duplex operation
Termination and bias resistors installed on-board and selectable by jumpers
RS-422 data signals : TX-, TX+, RX+, RX-, GND, RTS-, RTS+, CTS+, CTSRS-485 data signals (full-duplex) : TX-, TX+, RX+, RX-, GND
RS-485 data signals (half-duplex) : Data-, Data+, GND
LEDs indicate TxD and RxD
Wide input power range : 9V DC to 48V DC
Opto-isolated RS-232 to RS-422/RS-485 Converter (ES-R-2101B-M)
Converts RS-232 port to high speed RS-422 / RS-485 port
RS-232 port can be selected to DCE or DTE pin assignment
RS-422/RS-485 port is optically isolated with 2000 Volt DC optical isolation
RS-422/RS-485 port is surge protected on all signal lines to withstand electrostatic discharge
and power surges up to 25KV ESD
Data rate: 300 bps to 1M bps
RS-232 connector: One DB-9 female connector
RS-422 / RS-485 connector: One DB-9 male connector and one 5-pin terminal block
Auto transmit/receive control for 2-wire RS-485 half-duplex operation
Termination and bias resistors installed on-board and selectable by jumpers
RS-422 data signals : TX-, TX+, RX+, RX-, GND, RTS-, RTS+, CTS+, CTSRS-485 data signals (full-duplex) : TX-, TX+, RX+, RX-, GND
RS-485 data signals (half-duplex) : Data-, Data+, GND
LEDs indicate TxD and RxD
Wide input power range : 9V DC to 48V DC
©2010 - 2011 EasySYNC Ltd.
4
ES-R-2x01B-M
3
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Features of the ES-R-2x01B-M
3.1 Optical Isolation & Surge Protection (ES-R-2101B-M only)
The ES-R-2101B-M converter is optically isolated with 2000 Volt DC optical isolation. The optical isolation
protects the PC from spikes and surges on the RS-422/RS-485 network, by converting the electrical pulse
into an optical signal and then changing it back into an electrical pulse. The computer is well protected,
since the surges and spikes cannot cross the optical link.
The ES-R-2101B-M also features surge protectors, to withstand electrostatic discharge and power surges
up to 25KV ESD. The surge suppression on all signals prevents damage caused by lightning or high
voltage.
3.2 Power Supply
The ES-R-2001B-M and ES-R-2101B-M accept a wide range of supply voltages, from 9V DC to 48V DC.
The power input connector is a 3–pin terminal-block style connector as shown in Figure 1 below.
An external switch-mode power adapter is supplied with the converter.
Figure 1
9V DC to 48V DC power input connector
3.3 Enclosure
The ES-R-2001B-M and ES-R-2101B-M converters have a metal enclosure. Transmit and Receive LEDs
are included to show when data is being transmitted or received on the serial lines. A power LED is also
included to show that the converter is receiving power.
3.4 Configuring for RS-422 and RS-485 Modes
The ES-R-2001B-M and ES-R-2101B-M converters use DIP switches to select RS-422 or RS-485 modes.
They also feature jumpers to set the pinout of the RS-232 port to a DCE or DTE configuration, and to
enable termination and biasing when required.
Please refer to section 4 for more information on the DIP switch and jumper settings available.
©2010 - 2011 EasySYNC Ltd.
5
ES-R-2x01B-M
4
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Hardware Installation
4.1 General Notes and Warnings
Serial Bus Configuration
It is important to configure the DIP switches and jumpers to select the correct type of serial bus (RS-422
or RS-485) for your application before connecting the ES-R-2x01B-M converter to your serial bus.
Otherwise damage can occur to the converter or other equipment on the bus.
To avoid damage, the power supply and serial cables should be disconnected from your converter before
changing DIP switch settings and before opening the case to change jumper settings.
Termination
For RS-422 or RS-485, it may be necessary to enable termination of the data transmission lines. This
depends on the way in which your network is connected and if termination is already provided by other
devices on the network. Before applying the termination, check your cable specification for proper
impedance matching.
Termination is normally used in the node at each end of the bus, but nodes in the middle of the bus
should not have termination enabled. The ES-R-2x01B-M converters have jumpers to allow internal
termination resistors to be enabled if required. This avoids the need to provide an external resistor at the
ES-R-2x01B-M end of the bus.
Since a computer controlled serial port is normally at one end of the cable, termination is enabled by
default in the converter. If termination is not required, please disable this feature using the jumpers
inside the converter.
ES-R-2x01B-M converters have jumpers for both Tx ± termination and Rx ± termination. When using RS485 half-duplex, only the Tx ± termination should be enabled.
Biasing
For RS-485 half-duplex, it may be necessary to enable biasing of the data transmission lines. In some
cases, the RS-485 lines may float to undefined levels when no transmitter is active. This can cause
additional unexpected characters to appear at the start or end of a message. Biasing resistors are used to
guarantee a defined logic level on the serial lines when no node is transmitting.
The ES-R-2x01B-M models feature internal 750 ohm resistors with jumpers to enable/disable them.
These should be disabled if another device on your serial bus already provides biasing as biasing of data
lines must only occur at a single point in the cabling. They are typically not required in RS-422 and some
RS-485 full-duplex applications since the transmitter is always enabled.
The ES-R-2x01B-M converters have four jumpers to select biasing on Tx+, Tx-, Rx+ and Rx-. For biasing
of an RS-485 half-duplex bus, enable only the Rx biasing (Pull-up Rx+ to VCC by 750 Ohm Bias resistor
and Pull-down Rx- to GND by 750 Ohm Bias resistor). The Tx biasing (Pull-up Tx+ to VCC by 750 Ohm
Bias resistor and Pull-down Tx- to GND by 750 Ohm Bias resistor) should not be enabled as this would
provide two biasing resistors per line.
©2010 - 2011 EasySYNC Ltd.
6
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
4.2 RS-232 DCE or DTE Pin Assignment
Inside the unit, there are two 2x3 (JP1, JP2) header blocks which are jumpered to select the RS-232 port
pin assignment to DCE or DTE. The factory default setting is DCE.
Jumper
JP1
JP1
JP2
JP2
JP1
JP1
JP2
JP2
1-3
2-4
1-3
2-4
3-5
4-6
3-5
4-6
Function
RS-232 port assigned to DCE (Data Communications Equipment). See
Figure 2.
RS-232 port assigned to DTE (Data Terminal Equipment). See See
Figure 2.
Table 1
Jumper settings for RS-232 DCE or DTE Pin Assignment
DCE setting
2
1
4
3
6
5
JP2
2
1
4
3
6
5
JP1
Jumper pin numbers
Figure 2
DTE setting
Jumpers used to select RS-232 DCE and DTE
4.3 RS-422 and RS-485 Mode Block Configuration
A 3-pin DIP switch is used to set to select the mode of operation. The switches should be set to RS-422
mode or RS-485 mode as per the requirements of your application.
The RS-422 & RS-485 Mode Block Configuration Settings are shown in Table 2.
RS-422
Operation Mode
S1
S2
S3
4 wire with handshaking
ON
ON
ON
Full Duplex (4 wire)
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
Half Duplex (2 wire)
with Echo
Half Duplex (2 wire )
without Echo
RS-485
Table 2
RS-422 and RS-485 configuration
©2010 - 2011 EasySYNC Ltd.
7
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
4.4 Termination and Biasing Configuration
Inside the converter, there is a 7x3 (21pin) header block which has jumpers to enable the Tx, Rx and
CTS 120 Ohm termination resistors, and the Tx and Rx 750 Ohm biasing resistors. Open the case and set
the jumpers as per the requirements of your application. The settings are detailed below.
21 20 19
3
Figure 3
2
1
Setting termination and biasing resistors
Jumper
Function
1-2
enable
Tx± Termination of 120 Ohm.
2-3
disable
This function should be enabled for RS485 Half-Duplex mode.
4-5
enable
Pull-up Tx+ to VCC by 750 Ohm Bias resistor.
5-6
disable
This function should be enabled to pull-up Tx+.
7-8
enable
Pull-down Tx- to GND by 750 Ohm Bias resistor.
8-9
disable
This function should be enabled to pull-down Tx-.
10-11 enable
Rx± Termination of 120 Ohm.
11-12 disable
This function should be enabled for RS-422 and RS485 Full-Duplex mode.
13-14 enable
Pull-up Rx+ to VCC by 750 Ohm Bias resistor.
14-15 disable
This function should be enabled to pull-up Rx+.
16-17 enable
Pull-down Rx- to GND by 750 Ohm Bias resistor.
17-18 disable
This function should be enabled to pull-down Rx-.
19-20 enable
CTS Termination of 120 Ohm.
20-21 disable
This function should be enabled for RS-422 mode.
Note: See section 4.1 for further information before setting termination and biasing
Table 3
Termination and Biasing configuration
©2010 - 2011 EasySYNC Ltd.
8
ES-R-2x01B-M
5
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Connector Pinout Information
This section shows the connector pinouts used on the ES-R-2001B-M and ES-R-2101B-M converters.
This allows the use of a straight-through cable between the host computer and the RS-232 port of the
ES-R-2x01B-M.
5.1 RS-232 Signal Pin-outs of DB-9 Female (DCE)
Pin Number
Description
1
DCD = Data Carrier Detect
2
RXD = Receive Data
3
TXD = Transmit Data
4
DTR = Data Terminal Ready
5
GND = RS232 signal ground
6
DSR = Data Set Ready
7
RTS = Request To Send
8
CTS = Clear To Send
9
No Connect
Table 4
RS-232 Pin-Out for DB-9 connector (DCE)
5.2 RS-232 Signal Pin-outs of DB-9 Female (DTE)
Pin Number
Description
1
DCD = Data Carrier Detect
2
TXD = Transmit Data
3
RXD = Receive Data
4
DSR = Data Set Ready
5
GND = RS232 signal ground
6
DTR = Data Terminal Ready
7
CTS = Clear To Send
8
RTS = Request To Send
9
No Connect
Table 5
RS-232 Pin-Out for DB-9 connector (DTE)
©2010 - 2011 EasySYNC Ltd.
9
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
5.3 RS-422 Signal Pin-out
DB-9 Male connector
The table below shows the RS-422 pin-out of the DB-9 Male connector.
Pin Number
Description
1
TxD- = Transmit data, negative polarity
2
TxD+ = Transmit data, positive polarity
3
RxD+ = Receive data, positive polarity
4
RxD- = Receive data, negative polarity
5
GND = Signal ground
6
RTS- = Request to send, negative polarity
7
RTS+ = Request to send, positive polarity
8
CTS+ = Clear to send , positive polarity
9
CTS- = Clear to send, negative polarity
Table 6
RS-422 Pin-Out for DB-9 connector
5-way Terminal Block
The table below shows the RS-422 pin-out of the 5-way terminal block.
Pin Number
Description
1
TxD- = Transmit data, negative polarity
2
TxD+ = Transmit data, positive polarity
3
RxD+ = Receive data, positive polarity
4
RxD- = Receive data, negative polarity
5
GND = Signal ground
Table 7
RS-422 Pin-Out for 5-way terminal block
©2010 - 2011 EasySYNC Ltd.
10
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Wiring diagrams
The following diagram shows an RS-422 full-duplex bus. The ES-R-2x01B-M converters have a built-in
resistor for terminating their RxD ± input, which can be enabled using a jumper. The Tx ± lines which are
outputs from the ES-R-2x01B-M are terminated at the receiver at the other end of the bus as shown.
Twisted pair wires are required for each signal pair.
ES-R-2x01B-M
RS-422 Device
TxD+
RxD+
TxD-
RxD-
RxD+
TxD+
RxD-
TxD-
GND
GND
Figure 4
RS-422 4 Wire Full Duplex
The following diagram shows an RS-422 full-duplex bus with handshaking signals connected. The ES-R2x01B-M converters have built-in resistors for terminating their RxD ± and CTS ± inputs, which can be
enabled using jumpers. The TxD ± and RTS ± lines which are outputs from the ES-R-2x01B-M are
terminated at the receiver at the other end of the bus as shown. Twisted pair wires are required for each
signal pair.
ES-R-2x01B-M
RS-422 Device
TxD+
RxD+
TxD-
RxD-
RxD+
TxD+
RxD-
TxD-
GND
GND
RTS+
CTS+
RTS-
CTS-
CTS+
RTS+
CTS-
RTS-
Figure 5
RS-422 with handshaking signals connected
©2010 - 2011 EasySYNC Ltd.
11
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
5.4 RS-485 Signal Pin-out (half duplex)
DB-9 Male connector
The table below shows the RS-485 (half duplex) pinout of the DB-9 male connector.
Pin Number
Description
1
Data– = Transmit / Receive Data, negative polarity
2
Data+ = Transmit / Receive Data, positive polarity
5
GND = Signal ground
Note: Other pins have no function in this mode and should be left unconnected.
Table 8
RS-485 half-duplex pin-out for DB-9 connector
5-way Terminal Block
The table below shows the RS-485 (half duplex) pinout of the 5 way terminal block.
Pin Number
Description
1
Data– = Transmit / Receive Data, negative polarity
2
Data+ = Transmit / Receive Data, positive polarity
5
GND = Signal ground
Note: Other terminals have no function in this mode and should be left unconnected.
Table 9
RS-485 half-duplex pin-out for 5-way terminal block
©2010 - 2011 EasySYNC Ltd.
12
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Wiring Diagrams
The diagram shows an ES-R-2x01B-M converter connected to an RS-485 half-duplex bus. If the ES-R2x01B-M is at one end of the bus (as shown), the built-in resistor can be enabled to terminate the Data
± lines. The Tx ± termination jumper is used to enable this resistor. A second termination resistor is
fitted at the other end of the bus as shown.
If additional unexpected zero bytes are being received, the ES-R-2x01B-M converters also features bias
resistors (not shown below) which can be enabled by enabling the Pull-up Rx+ to VCC by 750 Ohm Bias
resistor and Pull-down Rx- to GND by 750 Ohm Bias resistor) jumpers. For further details see sections
4.1 and 4.4. These should not be enabled if another device on the bus is already providing biasing.
Twisted pair wires are required for each signal pair.
ES-R-2x01B-M
RS-485 Devices
Data+
DataData+
GND
DataGND
Data+
DataGND
Data+
DataGND
Figure 6
RS-485 Half Duplex Wiring
©2010 - 2011 EasySYNC Ltd.
13
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
5.5 RS-485 Signal Pin-out (full duplex)
DB-9 Male connector
The table below shows the RS-485 (full duplex) pinout of the DB-9 male connector.
Pin Number
Description
1
TxD- = Transmit data, negative polarity
2
TxD+ =
3
RxD+ = Receive data, positive polarity
4
RxD– = Receive data, negative polarity
5
GND = Signal ground
Transmit data, positive polarity
Note: Other pins have no function in this mode and should be left un-connected.
Table 10
RS-485 full duplex pin-out for DB-9 connector
5-way Terminal Block
The table below shows the RS-485 (full duplex) pinout of the 5 way terminal block.
Pin Number
Description
1
TxD- = Transmit data, negative polarity
2
TxD+ = Transmit data, positive polarity
3
RxD+ = Receive data, positive polarity
4
RxD– = Receive data, negative polarity
5
GND = Signal ground
Table 11
RS-485 full duplex pin-out for terminal block
©2010 - 2011 EasySYNC Ltd.
14
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Wiring Diagrams
The following diagram shows an RS-485 full-duplex bus. The ES-R-2x01B-M has a built-in resistor for
terminating its RxD ± input, which can be enabled using a jumper. The Tx ± lines which are outputs from
the ES-R-2x01B-M would be terminated at the receiver at the other end of the bus as shown. Twisted
pair wires are required for each signal pair.
ES-R-2x01B-M
RS-485 Device
TxD+
RxD+
TxD-
RxD-
RxD+
TxD+
RxD-
TxD-
GND
GND
Figure 7
RS-485 Full Duplex Wiring
©2010 - 2011 EasySYNC Ltd.
15
ES-R-2x01B-M
6
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Contact Information
Head Office – Glasgow, UK
EasySYNC Limited
Unit 1, 2 Seaward Place,
Centurion Business Park
Glasgow, G41 1HH
United Kingdom
Tel: +44 (0) 141 418 0181
Fax: +44 (0) 141 418 0110
E-mail (Sales)
E-mail (Support)
E-mail (General Enquiries)
Web Site URL
Web Shop URL
[email protected]
[email protected]
[email protected]
http://easysync-ltd.com
http://easysync-ltd.com
Branch Office – Hillsboro, Oregon, USA
EasySYNC Limited (USA)
7235 NW Evergreen Parkway, Suite 600
Hillsboro, OR 97123-5803
USA
Tel: +1 (503) 547 0909
Fax: +1 (503) 547 0990
E-Mail (Sales)
E-Mail (Support)
E-Mail (General Inquiries)
Web Site URL
Web Shop URL
[email protected]
[email protected]
[email protected]
http://easysync-ltd.com
http://easysync-ltd.com
©2010 - 2011 EasySYNC Ltd.
16
ES-R-2x01B-M
7
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Legal Disclaimer
System and equipment manufacturers and designers are responsible to ensure that their systems, and
any EasySYNC devices incorporated in their systems, meet all applicable safety, regulatory and systemlevel performance requirements. All application-related information in this document (including
application descriptions, suggested EasySYNC devices and other materials) is provided for reference only.
While EasySYNC has taken care to assure it is accurate, this information is subject to customer
confirmation, and EasySYNC disclaims all liability for system designs and for any applications assistance
provided by EasySYNC. Use of EasySYNC devices in life support and/or safety applications is entirely at
the user’s risk, and the user agrees to defend, indemnify and hold harmless EasySYNC from any and all
damages, claims, suits or expense resulting from such use. This document is subject to change without
notice. No freedom to use patents or other intellectual property rights is implied by the publication of this
document. Neither the whole nor any part of the information contained in, or the product described in
this document, may be adapted or reproduced in any material or electronic form without the prior written
consent of the copyright holder. EasySYNC Ltd, Unit 1, 2 Seaward Place, Centurion Business Park,
Glasgow G41 1HH, United Kingdom. Scotland Registered Company Number: SC224924
©2010 - 2011 EasySYNC Ltd.
17
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Appendix A - List of Figures and Tables
List of Figures
Figure 1
9V DC to 48V DC power input connector .................................................. 5
Figure 2
Jumpers used to select RS-232 DCE and DTE ........................................... 7
Figure 4
RS-422 4 Wire Full Duplex ..................................................................... 11
Figure 5
RS-422 with handshaking signals connected ......................................... 11
Figure 6
RS-485 Half Duplex Wiring ..................................................................... 13
Figure 7
RS-485 Full Duplex Wiring ..................................................................... 15
List of Tables
Table 1
Jumper settings for RS-232 DCE or DTE Pin Assignment ............................ 7
Table 2
RS-422 and RS-485 configuration .............................................................. 7
Table 3
Termination and Biasing configuration ....................................................... 8
Table 4
RS-232 Pin-Out for DB-9 connector (DCE) ................................................. 9
Table 5
RS-232 Pin-Out for DB-9 connector (DTE) .................................................. 9
Table 6
RS-422 Pin-Out for DB-9 connector .......................................................... 10
Table 7
RS-422 Pin-Out for 5-way terminal block ................................................. 10
Table 8
RS-485 half-duplex pin-out for DB-9 connector ....................................... 12
Table 9
RS-485 half-duplex pin-out for 5-way terminal block ............................... 12
Table 10
RS-485 full duplex pin-out for DB-9 connector ...................................... 14
Table 11
RS-485 full duplex pin-out for terminal block ........................................ 14
©2010 - 2011 EasySYNC Ltd.
18
ES-R-2x01B-M
Document Reference No.: ES_000086
RS-232 to RS-422/RS-485 Converters Manual
Version 1.0
Clearance No.: ES#42
Appendix B - Revision History
Version 1.0
24th August 2011
First Release
©2010 - 2011 EasySYNC Ltd.
19
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
EasySync:
ES-R-2001B-M ES-R-2101B-M
Similar pages