AIMTEC AMEPR30D-4270AZ-220 Up to 2a | ac-dc led driver Datasheet

Click on Series name for product info on aimtec.com
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
FEATURES:




AC-DC Constant current LED Driver
Input range 90-264VAC/47-440Hz
Active PFC with TRIAC dimmable②
Operating temperature -20 to 80°C




Leading or Trailing Edge Triac
IP67 Case
High Efficiency up to 87%
SCP, Over Load Protection
 Total Harmonic Distortion < 20%
 5 Year Limited Warranty
Models
Single output
Model
+Suffix②
AMEPR30D-5070AZ
AMEPR30D-4270AZ+Suffix②
AMEPR30D-3670AZ+Suffix②
AMEPR30D-36100AZ+Suffix②
AMEPR30D-24125AZ+Suffix②
AMEPR30D-24140AZ+Suffix②
AMEPR30D-15200AZ+Suffix②
Max
Output
Power
(W)①
Output
Voltage
Range
(V)
No Load
Output
Voltage
(V max.)
Output
Current (A)
35
29.4
25.2
36
30
33.6
30
36-50
32-42
24-36
24-36
12-24
12-24
8-15
64
54
52
52
34
34
23
0.7
0.7
0.7
1
1.25
1.4
2
Input Voltage
(VAC/Hz)
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
Efficiency
(%)
115
230
VAC
VAC
82
84
83
83
82
80
78
85
87
84
84
84
83
80
①
Exceeding the maximum output power will permanently damage the converter.
②
Model Nomenclature for Ordering:
Add Suffix “-U”
Universal AC input 90-264VAC, (no TRIAC dimming option)
Add Suffix “-110”
AC input 90-135VAC, 115VAC typical value
Add Suffix “-220”
AC input 180-264VAC, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/termssale
AMEPR30D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone
to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause
early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Conditions
Typical
115VAC
230VAC
15
30
0.25
500
350
Leakage current
AC current
Power Factor
External fuse
115VAC
230VAC
115VAC
230VAC
Recommended slow blow
type
Maximum
A
mA
mA
0.9
0.9
1
Start up time
Units
200
A
ms
Output Specifications
Parameters
Current accuracy
Line regulation
Load regulation
www.aimtec.com
F 052.1e R3.T
Conditions
Typical
LL-HL
0-100% load
±7
±10
±7
Tel: +1 514 620 2722
1 of 5
Maximum
Units
%
%
%
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
3
Ripple & Noise ③
Hold-up time
1
Minimum Load Voltage
See the models table
③ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
V p-p
ms
Isolation Specifications
Parameters
Conditions
Tested I/O voltage
Isolation Resistance
Typical
60sec
Maximum
Units
3000
VAC
MΩ
>1000
General Specifications
Parameters
Conditions
Typical
Switching frequency
Over load protection
Maximum
65
KHz
%
≧110
Over voltage protection
Short circuit protection
Over temperature protection
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Wires
Weight
Dimensions (L X H X W)
MTBF
With derating over 55°C
Units
%
≧110
Auto recovery
>105°C
-20 to +80
oC
100
oC
oC
-40 to +95
±0.02
Free air convection
% / oC
95
Plastic
UL1015 Input 18AWG*10CM/ Output 20 AWG * 10CM
200
133x33x30mm (5.24 x 1.30 x 1.18 inch)
>400,000 hrs (MIL-HDBK-217F at +25°C)
% RH
g
Environment Approval
Test
Shock
Vibration
Parameters
Wave form
Acceleration amplitude
Bump duration
Converter operation
Number of bumps
Test mode
Displacement
Acceleration
Converter operation
Conditions
Half sine wave
5gn
30 ms
Before and after test, body mounted (on chassis)
18 (3 in each direction for every axis)
Sweep sine, 10-100Hz, speed 0.05Hz/s
1 mm
3g, 3 loops 30min one cycle, 3h total, every axis tested
Before and after test, body mounted (on chassis)
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.T
cULus, CE, FCC
EN61347-1, EN61347-2-13, IEC62384, UL8750, UL60950-1, EN55015, EN55024, FCC Part 15 Subpart B, Class
B, ANSI C63.4 :2003
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient/Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 2
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 2
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Dimensions
Temperature Graph
Free Air Convection
55 º C
100
80
Safe Operating Area
60
40
20
0
- 25
- 20
0
20
40
60
Ambient Temperature
www.aimtec.com
F 052.1e R3.T
80
ºC
100
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Triac Dimming Feature
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Series AMEPR30D-AZ
up to 2A | AC-DC LED driver
Triac Dimming Performance
AMEPR30D-3670AZ
(mA)
Dimming Performance(Input 110Vac)
700
NS‐1223B
653
600
533
602
LUTRON DVCL‐
15SP‐WH
500
386
400
300
240
200
100
15
0
38
20
70
(mA)
120
170
Angle
Dimming Performance(Input 230 Vac)
800
712
700
629 614
600
NS‐1223C
678
609
Berker 286710
LUTRON LLSI‐
502B‐FAW‐M
LUTRON RNSI‐
452
525
500
427
449
400
300
257
205
200
158
75
100
20
0
20
70
96 102
70
120
170
220
Angle
Triac dimming performance is typical as with other models, for specific details on other model
performance, please see the Aimtec Triac Dimming Application note at www.aimtec.com
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet.
www.aimtec.com
F 052.1e R3.T
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC (924 6832)
North America only
Similar pages