Diodes BAS70-04Q-7-F Surface mount schottky barrier diode Datasheet

BAS70/ -04/ -05/ -06
SURFACE MOUNT SCHOTTKY BARRIER DIODE
Product Summary
VR(V)
IF (mA)
70
1.0
Features and Benefits
VF MAX (V)
@ +25°C
0.41
•
•
•
•
•
•
IR MAX (uA)
@ +25°C
0.1
Low Turn-On Voltage
Fast Switching
PN Junction Guard Ring for Transient and ESD Protection
Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
Halogen and Antimony Free. “Green” Device (Note 3)
Qualified to AEC-Q101 Standards for High Reliability
Description
Mechanical Data
70mA surface mount Schottky Barrier Diode in SOT23 package,
offers low forward voltage drop and fast switching capability,
designed with PN Junction Guard Ring for Transient and ESD
Protection.
•
•
•
•
•
•
•
Top View
BAS70
Case: SOT23
Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Solderable per MIL-STD-202, Method 208 e3
Lead Free Plating (Matte Tin Finish annealed over Alloy 42
leadframe)
Polarity: See Diagrams Below
Weight: 0.008 grams (approximate)
BAS70-04
BAS70-05
BAS70-06
Ordering Information (Note 4 & 5)
Part Number
BAS70-7-F
BAS70-04-7-F
BAS70-04Q-7-F
BAS70-04Q-13-F
BAS70-05-7-F
BAS70-06-7-F
Notes:
Case
SOT23
SOT23
SOT23
SOT23
SOT23
SOT23
Packaging
3000/Tape & Reel
3000/Tape & Reel
3000/Tape & Reel
10000/Tape & Reel
3000/Tape & Reel
3000/Tape & Reel
1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
4. For packaging details, go to our website at http://www.diodes.com/products/packages.html.
5. Product manufactured with Data Code V9 (week 33, 2008) and newer are built with Green Molding Compound. Product manufactured prior to Date Code
V9 are built with Non-Green Molding Compound and may contain Halogens or Sb2O3 Fire Retardants.
BAS70/ -04/ -05/ -06
Document number: DS11007 Rev. 24 - 2
1 of 5
www.diodes.com
August 2014
© Diodes Incorporated
BAS70/ -04/ -05/ -06
Cxx
Date Code Key
Year
2001
Code
M
Month
Code
Jan
1
Kxx
2002
N
2003
P
….
….
Feb
2
Mar
3
Apr
4
K=(SAT,Shanghai Assembly / Test site)
C=(CAT / DTC , ChengDu Assembly / Test site)
xx = Product Type Marking Code:
73, 7C = BAS70
74, 7D = BAS70-04
75, 7E = BAS70-05
76, 7F = BAS70-06
YM = Date Code Marking
Y = Year (ex: B = 2014)
M = Month (ex: 9 = September)
YM
YM
Marking Information
2011
Y
2012
Z
May
5
2013
A
Jun
6
2014
B
Jul
7
2015
C
Aug
8
2016
D
Sep
9
2017
E
Oct
O
2018
F
2019
G
Nov
N
Dec
D
Maximum Ratings (@TA = +25°C, unless otherwise specified.)
Characteristic
Symbol
Value
Unit
VRRM
VRWM
VR
70
V
VR(RMS)
49
V
IFM
70
mA
IFSM
100
mA
Symbol
Value
Unit
PD
200
mW
RθJA
625
°C/W
TJ
-55 to +125
°C
TSTG
-65 to +150
°C
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
RMS Reverse Voltage
Maximum Forward Continuous Current (Note 6)
Non-Repetitive Peak Forward Surge Current
@ t ≤ 1.0s
Thermal Characteristics
Characteristic
Power Dissipation (Note 6)
Thermal Resistance Junction to Ambient Air (Note 6)
Operating Junction Temperature Range
Storage Temperature Range
Electrical Characteristics (@TA = +25°C, unless otherwise specified.)
Characteristic
Max
Unit
70
—
V
VF
—
410
1000
mV
tp <300µs, IF = 1.0mA
tp <300µs, IF = 15mA
Reverse Current (Note 7)
IR

100
nA
tp <300µs, VR = 50V
Total Capacitance
CT

2.0
pF
VR = 0V, f = 1.0MHz
Reverse Recovery Time
trr
—
5.0
ns
IF = IR = 10mA to IR = 1.0mA,
RL =100Ω
Reverse Recovery Time (for BAS70-04 only)
trr
—
2.0
ns
IF = IR = 10mA to IR = 1.0mA,
RL =100Ω
Reverse Breakdown Voltage (Note 7)
Forward Voltage
Notes:
6.
7.
Symbol
Min
V(BR)R
Test Condition
IR = 10µA
Part mounted on FR-4 board with recommended pad layout, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf.
Short duration pulse test used to minimize self-heating effect.
BAS70/ -04/ -05/ -06
Document number: DS11007 Rev. 24 - 2
2 of 5
www.diodes.com
August 2014
© Diodes Incorporated
250
PD, POWER DISSIPATION (mW)
Note 6
200
150
100
50
0
40
120
160
80
200
TA, AMBIENT TEMPERATURE (°C)
Figure 1 Power Derating Curve, Total Package
100
TA = 125ºC
TA = 75ºC
TA = 25ºC
10
1.0
TA = 0ºC
TA = -40ºC
0.1
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Figure 2 Typical Forward Characteristics
1.8
10,000
1.6
1,000
CT, TOTAL CAPACITANCE (pF)
IR, INSTANTANEOUS REVERSE CURRENT (nA)
0
IF, INSTANTANEOUS FORWARD CURRENT (mA)
BAS70/ -04/ -05/ -06
100
10
1
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.1
0
0
40
50
10
20
30
60
70
VR, INSTANTANEOUS REVERSE VOLTAGE (V)
Figure 3 Typical Reverse Characteristics
BAS70/ -04/ -05/ -06
Document number: DS11007 Rev. 24 - 2
3 of 5
www.diodes.com
0
20
25
35 40
15
30
10
VR, DC REVERSE VOLTAGE (V)
Figure 4 Total Capacitance vs. Reverse Voltage
5
August 2014
© Diodes Incorporated
BAS70/ -04/ -05/ -06
Package Outline Dimensions
Please see AP02002 at http://www.diodes.com/datasheets/ap02002.pdf for latest version.
All 7°
H
K1
SOT23
Dim
Min
Max
Typ
A
0.37
0.51
0.40
B
1.20
1.40
1.30
C
2.30
2.50
2.40
D
0.89
1.03 0.915
F
0.45
0.60 0.535
G
1.78
2.05
1.83
H
2.80
3.00
2.90
J
0.013 0.10
0.05
K
0.890 1.00 0.975
K1
0.903 1.10 1.025
L
0.45
0.61
0.55
L1
0.25
0.55
0.40
M
0.085 0.150 0.110
a
8°
All Dimensions in mm
J
K
a
M
A
L
C
L1
B
D
Suggested Pad Layout
Please see AP02001 at http://www.diodes.com/datasheets/ap02001.pdf for the latest version.
Y
Z
C
X
BAS70/ -04/ -05/ -06
Document number: DS11007 Rev. 24 - 2
Dimensions Value (in mm)
Z
2.9
X
0.8
Y
0.9
2.0
C
1.35
E
E
4 of 5
www.diodes.com
August 2014
© Diodes Incorporated
BAS70/ -04/ -05/ -06
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
This document is written in English but may be translated into multiple languages for reference. Only the English version of this document is the
final and determinative format released by Diodes Incorporated.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2014, Diodes Incorporated
www.diodes.com
BAS70/ -04/ -05/ -06
Document number: DS11007 Rev. 24 - 2
5 of 5
www.diodes.com
August 2014
© Diodes Incorporated
Similar pages