AIMTEC AM6GH-2405SZ 6 watt | dc-dc converter Datasheet

Click on Series name for product info on aimtec.com
Series AM6GH-Z
6 Watt | DC-DC Converter
FEATURES:
 SIP8 Package
 High Efficiency up to 87%
 On / Off Control
 No Minimum Load




Operating Temperature -40°C to +85°C
Continuous Short Circuit Protection
Input / Output Isolation 1500 & 3000 VDC
Wide 4:1 Input Range
Models
Single Output
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current Max
(mA)
Isolation
(VDC)
AM6GH-2403SZ
AM6GH-2405SZ
AM6GH-2409SZ
AM6GH-2412SZ
AM6GH-2415SZ
AM6GH-2424SZ
AM6GH-4803SZ
AM6GH-4805SZ
AM6GH-4809SZ
AM6GH-4812SZ
AM6GH-4815SZ
AM6GH-4824SZ
9-36
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
18-75
3.3
5
9
12
15
24
3.3
5
9
12
15
24
1500
1200
666
500
400
250
1500
1200
666
500
400
250
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
261
298
290
287
287
287
131
151
147
144
144
144
AM6GH-2403SH30Z
AM6GH-2405SH30Z
AM6GH-2409SH30Z
AM6GH-2412SH30Z
AM6GH-2415SH30Z
AM6GH-2424SH30Z
AM6GH-4803SH30Z
AM6GH-4805SH30Z
AM6GH-4809SH30Z
AM6GH-4812SH30Z
AM6GH-4815SH30Z
AM6GH-4824SH30Z
9-36
9-36
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
18-75
18-75
3.3
5
9
12
15
24
3.3
5
9
12
15
24
1500
1200
666
500
400
250
1500
1200
666
500
400
250
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
261
298
290
287
287
287
131
151
147
144
144
144
Input
Voltage
(V)
Output
Voltage
(V)
Output
Current Max
(mA)
Isolation
(VDC)
9-36
9-36
9-36
18-75
18-75
18-75
±5
±12
±15
±5
±12
±15
±600
±250
±200
±600
±250
±200
1500
1500
1500
1500
1500
1500
Model
Input Current
Full | No Load
(mA)
Capacitor
Load
(μF)
Efficiency
(%)
6
6
6
6
6
6
6
6
6
6
6
6
4700
2200
1000
470
220
100
4700
2200
1000
470
220
100
79
84
86
87
87
87
79
83
85
87
87
87
6
6
6
6
6
6
6
6
6
6
6
6
4700
2200
1000
470
220
100
4700
2200
1000
470
220
100
79
84
86
87
87
87
79
83
85
87
87
87
Capacitor
Load
(μF)
Efficiency
(%)
±330
±220
±100
±330
±220
±100
84
86
87
82
85
86
Models
Dual output
Model
AM6GH-2405DZ
AM6GH-2412DZ
AM6GH-2415DZ
AM6GH-4805DZ
AM6GH-4812DZ
AM6GH-4815DZ
Input Current
Full | No Load
(mA)
298
291
287
152
147
145
6
6
6
6
6
6
AM6GH-2405DH30Z
9-36
±5
±600
3000
298
6
±330
84
AM6GH-2412DH30Z
9-36
±12
±250
3000
291
6
±220
86
AM6GH-2415DH30Z
9-36
±15
±200
3000
287
6
±100
87
AM6GH-4805DH30Z
18-75
±5
±600
3000
152
6
±330
82
AM6GH-4812DH30Z
18-75
±12
±250
3000
147
6
±220
85
AM6GH-4815DH30Z
18-75
±15
±200
3000
145
6
±100
86
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified
www.aimtec.com
F 051e R11.A
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6GH-Z
6 Watt | DC-DC Converter
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
Filter
Transient recovery time
Transient Response deviation
On / Off Control
Input reflected ripple current*
Units
VDC
µs
±3
±5
3.3 & 5 V output
Start up time
Absolute Maximum Rating
Maximum
9-36
18-75
Capacitor
250
%
30
-0.7-50
-0.7-100
24 Vin
48 Vin
ms
VDC
ON – high impedance or open;
OFF – 2-4mA input current through 1KΩ (standby 2.5mA max)
24Vin
20
48Vin
40
mA p-p
* The input reflected ripple current should be measured with connected 12μH inductor and 47μF input capacitor (ESR<1Ω at 100 KHz)
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
Typical
3 sec
Rated
Units
1500 & 3000
VDC
MOhm
pF
Maximum
Units
> 1000
50
Output Specifications
Parameters
Conditions
Typical
Voltage accuracy
Cross Regulation (Dual)
Short Circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
1st output 25% to 100%, 2nd
output 100%
±1
%
±5
%
Continuous
Auto recovery
±0.2
±0.5
±1.0
±0.02
125
LL~HL
(0 to 100% load) Single
(0 to 100% load) 3V, 5V, & Dual
At 20MHz Bandwidth
%
%
%/oC
mV p-p
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Potting material
Pin Material
Weight
Dimensions (L X W X H)
MTBF
www.aimtec.com
F 051e R11.A
Conditions
Typical
100% load
Derating Chart at +71
580
Maximum
Units
+100
KHz
o
C
oC
oC
-40 to +85
-55 to +125
Free air convection
95
Non-conductive black plastic
epoxy (UL94V-0 rated)
C5191R-H Solder coated
4.8
0.86 x 0.36 x 0.44 inch
21.85 x 9.20 x 11.10 mm
>TBD hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Tel: +1 514 620 2722
2 of 5
%
g
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6GH-Z
6 Watt | DC-DC Converter
Safety Specifications
Parameters
Agency Approvals
CE
EN55022 Class A, EN55024 (external circuit required)
IEC61000-4-2, Perf. Criteria A
IEC61000-4-3, Perf. Criteria A
IEC61000-4-4, Perf. Criteria A (external circuit required)
IEC61000-4-5, Perf. Criteria A (external circuit required)
IEC61000-4-6, Perf. Criteria A
IEC61000-4-8, Perf. Criteria A
NOTE: designed to meet IEC 60950-1:2001
Standards
Pin Out Specifications
Pin
1
2
3
5
6
7
8
1500 VDC
Single
Dual
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
- V Output
N.C.
- V Input
+ V Input
On/Off Control
N.C.
+ V Output
Common
- V Output
3000 VDC
Single
Dual
- V Input
+ V Input
On/Off Control
No Pin
+ V Output
- V Output
N.C.
- V Input
+ V Input
On/Off Control
No Pin
+ V Output
Common
- V Output
Dimensions
Input Reflected Ripple Test Circuit
www.aimtec.com
F 051e R11.A
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6GH-Z
6 Watt | DC-DC Converter
Derating
Output Power( % )
Free Air Convection
71C
100
80
60
Safe Operating Area
50
40
20
71
0
85
- 40 - 20 0 20 40 60 80 100
Ambient Temperature º C
EMI, external filter
C6
C3
L
12uH
C1
+V output
+V input
DC/DC
Converter
Load
C2
-V input
-V output
C4
C5
Vin
24VDC
48VDC
C1 & C2
10µF/35V, MLCC
2.2µF/100V, MLCC
www.aimtec.com
F 051e R11.A
C3 & C4
470pF/3KV, MLCC
1000pF/3KV, MLCC
C5 & C6
1000pF/3KV, MLCC
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6GH-Z
6 Watt | DC-DC Converter
EFT/Surge Application circuit
+Vout
+Vin
DC/DC
Converter
C1
D1
Load
-Vin
-Vout
Vin
24VDC
48VDC
C1
300µF/100V
470µF/100V
D1
TVS, 3kW, 75V
TVS, 3kW, 130V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R11.A
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages