ETC2 DP-100 Dual display digital pressure sensor for gas Datasheet

667
FIBER
SENSORS
Dual Display Digital Pressure Sensor
DP-100 SERIES
Related Information
LASER
SENSORS
■■General terms and conditions............ F-17
■■SC-SU1........................................... P.917
■■General precautions...................... P.1405
For Gas
■■Sensor selection guide.................. P.661~
■■Glossary of terms.......................... P.1373
■■Korea’s S-mark.............................. P.1410
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
Recognition
AREA
SENSORS
Certified
[DP-101(A)/102(A) only]
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
* Passed the UL 991 Environment Test
SENSOR
OPTIONS
* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic-electric-works.net/sunx
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Digital
Auto reference With analog
output
Dual 3-color display makes operation easier!
The dual display means that the “current value” and the “threshold value”, it makes direct setting of threshold value
Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold
value can be checked at the same time, the threshold value can be set and checked smoothly without having to
switch screen modes. ON / OFF operations are still carried out while the threshold values are being set, so setting to
the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped.
FA COMPONENTS
Current value
Previous model with single display
Threshold value setting method
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
–91.8
Note current value
Operate MODE key
Adjust threshold value
Return to RUN operation
DP-100 with dual display
Simply press a button
during RUN operation
Man-hours reduced by
3/4
Threshold value
Flow
Other Products
DP-100
DP-M
3-color display (Red, Green, Orange)
Readable digital display
The main display changes color in line with changes
in the status of output ON / OFF operation, and it also
changes color while setting is in progress. The sensor
status can therefore be understood easily, and operating
errors can be reduced.
12 segments are used and an alphanumeric display has
been adopted. This improves visual checking of letters
and numbers.
Main
Display
OFF: Green (or Red)
ON: Red (or Green)
During normal operation
SET: Orange
During setting
Dual Display Digital Pressure Sensor
DP-100 SERIES
APPLICATIONS
668
FIBER
SENSORS
Confirming suction of electronic component
Confirming reference pressure
Air-leak test for PET bottles
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
BASIC PERFORMANCE
All models in the line-up are compound pressure types
High performance accomplished Low pressure type
No sensor settings are required to switch between positive pressure and negative
pressure, so that the number of registered part numbers can be decreased.
The low pressure type displays measurements in 0.1 kPa
at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
characteristics and ±0.1 % F.S. repeatability, giving it
high performance.
<For low pressure>
Ideal for applications such
as suction.
No mis-operations due to
vacuum breakdown occur.
–100 kPa
For low
pressure
<For high pressure>
100 kPa
0 kPa
DP-101□
Ideal for applications such as
checking reference pressure.
Can also be used for simple
suction.
1 MPa
For high
pressure
DP-102□
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
Displays measurements in 0.1 kPa
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
FUNCTIONS
HUMAN MACHINE
INTERFACES
Copy function reduces man-hours and human error
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to the other
sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number
of changes required to instruction manuals when equipment designs are changed.
Details transmitted
Copying via wiring
Master sensor
Power supply
+V
+V
0V
0V
Comparative output 1
Comparative output 1
Comparative output 2
Comparative output 2
Details received
Slave sensor
Detail
s cop
ied
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU
SETTING mode” for basic settings, and “PRO mode”
for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
Simple setting
RUN mode
MENU SETTING mode
Special and
detailed setting
PRO mode
Other Products
DP-100
RUN mode
Settings such as threshold value
adjustment and key lock operation
can be carried out while the sensor
is operating.
MENU SETTING mode
Basic settings such as output mode
setting and NO / NC switching can
be carried out.
PRO mode
High-level function settings such as
hysteresis adjustment and the copy
function can be carried out.
DP-M
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
FUNCTIONS
Equipped with independent dual output and three output modes
Equipped with two independent comparative outputs,
and separate sensing modes can be selected for each
of them. Since there are two comparative outputs, one
of the comparative outputs can even be used for alarm
output. In addition, if an output is not being used, it can
be disabled.
Vacuum breakdown can also be checked during suction applications!
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
ON
Comparative output 1
EASY mode
OFF
ON
Comparative output 2
EASY mode
OFF
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
–100 kPa
P-1
0 kPa
Alarm output
ON
LASER
MARKERS
Comparative output 2
EASY mode
OFF
PLC /
TERMINALS
0 kPa
Lo-1
Hi-1
P-2
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Hysteresis mode
Hi
H (Hysteresis)
Lo
0
ON
Comparative output
OFF
Note: “
” or “
output 1, and “
3
H: 1 digit or more
” appears in the sub display for comparative
” or “
” appears for comparative output 2.
Window comparator mode
This mode is used for setting comparative output ON
and OFF at pressures within the setting range.
H (Hysteresis)
Hi
H (Hysteresis)
Lo
0
ON
Comparative output
OFF
H: Fixed
Equipped with auto-reference / remote zero-adjustment functions, more precise pressure management is possible with a minimum of effort Multi-function type
If the reference pressure of the device changes, the auto-reference function
partially shift the comparative output judgment level by the amount that the
reference pressure shifts, and the remote zero-adjustment function can reset
the display value to zero via external input. These functions are ideal for
places where the reference pressure fluctuates wildly, or where fine settings
are desired.
With auto-reference function applied
Flow
Other Products
H: Fixed
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
” or “
” appears in the sub display for comparative
output 1, and “
” or “
” appears for comparative output 2.
FA COMPONENTS
UV CURING
SYSTEMS
0
ON
OFF
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
”appears in the sub display for comparative output 1, and
“
” appears for comparative output 2.
P-2
Reference
pressure
checking
ENDOSCOPE
MACHINE VISION
SYSTEMS
Comparative output
H (Hysteresis)
P
Vacuum breakdown checking
ON
Comparative output 1
hysteresis mode
OFF
STATIC CONTROL
DEVICES
EASY mode
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON / OFF control.
Reference pressure alarm output is possible during reference pressure checking!
MEASUREMENT
SENSORS
Standard type
This mode is used for comparative output ON / OFF control.
2
PARTICULAR
USE SENSORS
WIRE-SAVING
SYSTEMS
Suction checking
1
Pressure
LASER
SENSORS
DP-100 SERIES
Pressure
FIBER
SENSORS
Dual Display Digital Pressure Sensor
Pressure
669
With remote zero-adjustment function applied
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
Auto-reference input
The display remains at “30” and
only the threshold level is changed.
DP-100
DP-M
30
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
Remote zero-adjustment input
The display is forced to “0”, and only the
filling pressure drop range is displayed.
30
OK
25
20
Threshold level after applying
auto-reference input
15
0
–5
25
20
Threshold level after applying
remote zero-adjustment input
15
Threshold level before applying
auto-reference input
Threshold level before applying
remote zero-adjustment input
Trial 1
Pressure 0
–5
Trial 1
Pressure 0
Auto-reference input value…
Time
When auto-reference input is applied, the reference pressure “30”
is added to the threshold level. If the reference pressure changes
to “20” or “40”, the auto-reference input compensates for this
every time by changing the threshold level, so any variation in
the filling pressure can be ignored.
OK
–5
Time
Displayed when remote zero-adjustment
input is applied…
When remote zero-adjustment input is applied, the reference
pressure is forced to “0”. If the reference pressure changes to
“20” or “40”, the remote zero-adjustment input adjusts the
reference pressure to “0” every time the reference pressure
changes, so any variation in the filling pressure can be ignored.
Dual Display Digital Pressure Sensor
DP-100 SERIES
FUNCTIONS
Sub display can be customized
Setting details can be understood at a glance
The sub display can be set to indicate any other desired
values or letters apart from the threshold value. This
eliminates the need for tasks such as affixing a label to
the device to indicate the normal pressure value.
The DP-100 setting details appear in the digital display.
Because the settings are in numeric form that can be
easily understood, it is useful for times such as when
receiving technical support by telephone.
2nd digit: Setting status for
comparative output 2
1st digit: Setting status for
comparative output 1
3rd digit: Threshold value setting
4th digit: Display color setting
670
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
5th digit: Response time
setting
6th digit: Display unit setting
8th digit: ECO mode setting
7th digit: Display refresh rate setting
MOUNTING
MEASUREMENT
SENSORS
An exclusive mounting bracket that is suitable for 1 to 6
mm 0.039 to 0.236 in panel thickness is available.
Takes up
much
less space
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Tight installation to panels is possible
Tight installation is possible
SENSOR
OPTIONS
STATIC CONTROL
DEVICES
Front protection
cover available
MS-DP1-3
ENDOSCOPE
LASER
MARKERS
A single mounting hole!
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available
Space savings can also be obtained if an L-shaped mounting bracket is used.
• MS-DP1-1
• MS-DP1-5
FA COMPONENTS
Tight installation is possible
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Ceiling mounting
Floor mounting
Rear mounting
Positioning bosses for easier
mounting bracket installation
Cable can be connected with one-touch connection
Types without connector attached
cable are also available
The accessory connector
attached cable (2 m 6.562 ft)
can be connected easily with
one-touch connection.
Commercially-available connectors can be used for
cable connections. Only the required length of cable
needs to be used, which contributes to a reduced
amount of wastage for unneeded cable.
DP-10□-J
Environmentally
friendly
* Connection cable
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
Commercially-available
parts can be used!
Flow
Other Products
DP-100
DP-M
671
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Dual Display Digital Pressure Sensor
DP-100 SERIES
VARIETIES
DP-10□-M
Short pressure port type is lightweight and takes up little space
Compact size with a depth of only 30 mm 1.181 in, so
that it can easily fit into narrow spaces.
Further, 10 g lighter than standard types. This reduces
the loads on movable parts such as robot arms.
Standard type
M5 female thread + R 1/8 male thread
Elbow joint
Short pressure
port type DP-10□-M
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Short pressure port type
INDUCTIVE
PROXIMITY
SENSORS
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
M5 female thread
[Material: Stainless steel (SUS)]
30 mm
1.181 in
SIMPLE
WIRE-SAVING
UNITS
*T
he illustration shows connection using an elbow joint.
The elbow joint is sold separately.
M8 piug-in connector types are also available (for Europe)
STATIC
CONTROL
DEVICES
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)
ENDOSCOPE
DP-11□-E-P-J
M8 connector
LASER
MARKERS
PLC /
TERMINALS
G 1/8 male thread
M5 female thread
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Switch-over of the pressure port or flat mounting
For short pressure port type
on the wall is possible
Rc1/8 conversion bushing improves compatibility
with the previous model For short pressure port type
By mounting the flat
attachment to DP-10□-M(-P),
pressure port and cable can
now be pulled out in downward,
left or right directions. Flat
mounting on surfaces such as
the wall is made possible.
By equipping the push-in converter with DP-10□-M(-P),
pressure port can be converted from M5 female thread to
Rc1/8 female thread.
Bore diameter conversion to the DP2 / DP3 series is
possible.
Previous model DP2 / DP3
series can be switched over to
DP-100 series.
Previous model
Pressure/
Digital Display
Pressure/
Head-separated
Flow
M5 female thread
Rc1/8 female thread
Flat attachment
MS-DP1-F□
Other
Products
20 mm
0.787 in pitch
DP-100
Model No.
DP-M
3 possible directions to mount
20 mm
0.787 in pitch
Pressure port
MS-DP1-FM
M5 female thread
MS-DP1-FR
Rc1/8 female thread
MS-DP1-FN
NPT1/8 female thread
MS-DP1-FE
G1/8 female thread
Conversion bushing
MS-DP1-7
Dual Display Digital Pressure Sensor
DP-100 SERIES
ORDER GUIDE
FIBER
SENSORS
Asia
Type
Standard
Multi-function
Europe
M8 plug-in connector type
Multi-function
North America
Standard pressure port type
Standard
Standard
Multi-function
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
For low pressure
–100.0 to +100.0 kPa
For high pressure
–0.100 to +1.000 MPa
Standard
Multi-function
For high pressure
Standard
Asia
Short pressure port type
Rated pressure
range
Appearance
For low pressure
Multi-function
672
*CN-14A-C2
Connector attached
cable 2 m 6.562 ft
is attached.
Excluding M8 plug-in
connector type
(
(
)
–100.0 to +100.0 kPa
)
–0.100 to +1.000 MPa
Model No.
DP-101
DP-102
DP-101A
DP-102A
DP-101-E-P
DP-102-E-P
DP-101A-E-P
DP-102A-E-P
DP-111-E-P-J
DP-112-E-P-J
DP-111A-E-P-J
DP-112A-E-P-J
DP-101-N
DP-101-N-P
DP-102-N
DP-102-N-P
DP-101A-N
DP-101A-N-P
DP-102A-N
DP-102A-N-P
For low pressure
–100.0 to +100.0 kPa
DP-101-M
For high pressure
–0.100 to +1.000 MPa
DP-102-M
For low pressure
–100.0 to +100.0 kPa
DP-101A-M
For high pressure
–0.100 to +1.000 MPa
DP-102A-M
Type without connector attached cable
Type without connector attached cable CN-14A-C2 is available.
When ordering this type, suffix “-J” to the Model No.
(e.g.) Type without connector atlached cable of DP-101-N is “DP-101-N-J”
Accessory
• CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
LASER
SENSORS
Pressure
port
Comparative output
M5 female
thread
+
R 1/8
male thread
NPN open-collector transistor
M5 female
thread
+
G 1/8
male thread
PNP open-collector transistor
M5 female
thread
+
G 1/8
male thread
PNP open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
M5 female
thread
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
NPN open-collector transistor
M5 female
thread
+
NPT 1/8
male thread
PHOTOELECTRIC
SENSORS
NPN open-collector transistor
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
DP-100
DP-M
673
FIBER
SENSORS
Dual Display Digital Pressure Sensor
DP-100 SERIES
OPTIONS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Designation
Model No.
Connector attached cable
Description
• CN-14A-C□
• CN-14A-R-C□
CN-14A-C1
CN-14A-C2 (Note)
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-24A-C2
CN-24A-C5
CN-14A
Length: 1 m 3.281 ft
MS-DP1-1
Allows sensors to be installed on the flooring or ceiling. Multiple
sensors can also be mounted closely.
MS-DP1-5
Allows sensors to be installed on the wall. Multiple sensors can also
be mounted closely.
MS-DP1-2
Allows installation to panels with thickness of 1 to 6 mm 0.039 to
0.236 in. Multiple sensors can also be mounted closely.
MS-DP1-4
Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
set-up, please use panel mounting bracket MS-DP1-2 for panel mounting.
STATIC
CONTROL
DEVICES
Front protection
cover
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
ENDOSCOPE
Conversion
bushing
MS-DP1-7
By equipping with DP-10□-M(-P), pressure port can be converted to
Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
SC-SU1
M5 female thread
MICRO
PHOTOELECTRIC
SENSORS
Connector
attached cable
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
Connector
attached cable
(Flexible cable)
INDUCTIVE
PROXIMITY
SENSORS
M8 connector
attached cable
PARTICULAR
USE
SENSORS
Connector
SENSOR
OPTIONS
Sensor mounting
bracket
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Panel mounting
bracket
Flat
attachment
Copy unit
0.2 mm2 4-core cabtyre cable with connector
on one end
Cable outer diameter: ø3.7 mm ø0.146 in
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
0.2 mm2 4-core flexible cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm ø0.146 in
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
For M8 plug-in connector type
The connector on one end
Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in
Set of 10 housings and 40 contacts
Length: 2 m 6.562 ft
Pressure port and cable can now be pulled
out in downward, left or right directions. Flat
NPT1/8 female thread mounting on surfaces such as the wall is
made possible.
G1/8 female thread
Rc1/8 female thread
M8 connector attached cable
• CN-24A-C□
31.4
1.236
ø9
ø0.354
• MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-1
(
Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series.
(Excluding M8 plug-in connector type).
• MS-DP1-4
Front protection cover
MS-DP1-3
DP2 / DP3
DP
2-2
0
ñ101
.3kPa
Remove
OUT
1
OUT
2
0-AD
J
MOD
E
Remove
• MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-5
Insert
DP-100
Selection
Guide
Panel mounting bracket
MS-DP1-2
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
Flat attachment
• MS-DP1-FM
)
Sensor mounting
bracket
MS-DP1-1
Panel mounting bracket, Front protection cover
Front protection cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
(Unit: mm in)
Sensor mounting bracket
Copy the controller settings to other controllers.
• MS-DP1-2
• MS-DP1-3
ø4
ø0.157
Mounting holes
for DP2 / DP3 series
can be used as is.
(
)
Panel mounting bracket MS-DP1-4
Sensor mounting
bracket
MS-DP1-5
• MS-DP1-FR
• MS-DP1-FN
• MS-DP1-FE
DP-100
DP-M
Net weight: MS-DP1-FM 15 g approx.
MS-DP1-FR/FN/FE 25 g approx.
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws are attached.
Recommended connector
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg.Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Copy unit
Conversion bushing
• MS-DP1-7
M5 female
thread
Rc1/8 female
thread
• SC-SU1
Conversion bushing
MS-DP1-7
Dual Display Digital Pressure Sensor
DP-100 SERIES
SPECIFICATIONS
Item
Model No.
Type
FIBER
SENSORS
Standard
LASER
SENSORS
Multi-function
For low pressure
For high pressure
For low pressure
For high pressure
DP-101(-M)(-P)
DP-102(-M)(-P)
DP-101A(-M)(-P)
DP-102A(-M)(-P)
DP-101-E-P
DP-102-E-P
DP-101A-E-P
DP-102A-E-P
M8 plug-in connector type
DP-111-E-P-J
DP-112-E-P-J
DP-111A-E-P-J
DP-112A-E-P-J
North America (Note 2)
DP-101-N(-P)
DP-102-N(-P)
DP-101A-N(-P)
DP-102A-N(-P)
–100.0 to +100.0 kPa
–0.100 to +1.000 MPa
–100.0 to +100.0 kPa
–0.100 to +1.000 MPa
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
500 kPa
1.5 MPa
500 kPa
1.5 MPa
Asia (Note 2)
Europe
Type of pressure
Rated pressure range
Set pressure range
Pressure withstandability
Gauge pressure
Applicable fluid
Non-corrosive gas
Selectable unit
For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage
Power consumption
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less at STD (Current consumption 25 mA or less at 24 V supply voltage)
480 mW or less at FULL (Current consumption 20 mA or less at 24 V supply voltage)
<Asia (PNP output) , Europe, North America (PNP output)>
<Asia (NPN output) , North America (NPN output)>
PNP open-collector transistor
NPN open-collector transistor
Comparative output
• Maximum source current: 100 mA
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between comparative output and +V)
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Residual voltage: 2 V or less (at 100 mA source current)
• Residual voltage: 2 V or less (at 100 mA sink current)
Output operation / Output modes
NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis
Repeatability
Response time
Minimum 1 digit (variable) (however, 2 digits when using psi unit)
±0.1 % F.S. (within ±2 digits)
±0.2 % F.S. (within ±2 digits)
External input (Note 3)
Auto-reference function /
Remote zero-adjustment
function
–
Analog voltage output (Note 3)
–
Displayable pressure
range
Incorporated
<Asia (NPN output) , North America
(NPN output)>
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Output voltage: 1 to 5 V DC
Zero point: within 3 V ± 5 % F.S.
Span: within 4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Environmental resistance
Protection
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
±0.2 % F.S. (within ±2 digits)
<Asia (PNP output) , Europe,
North America (PNP output)>
ON voltage: 5 V to +V DC
OFF voltage: 0.6 V DC or less, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Output voltage: 0.6 to 5 V
Zero point: within 1 V ± 5 % F.S.
Span: within 4.4 V ± 5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
Orange LED
Indicator
±0.1 % F.S. (within ±2 digits)
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection
Display
Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON
–100.0 to +100.0 kPa
–1.020 to +1.020 kgf/cm2
–1.000 to +1.000 bar
–14.50 to +14.50 psi
–750 to +750 mmHg
–29.5 to +29.5 inHg
–0.100 to +1.000 MPa
–100 to +1,000 kPa
–1.02 to +10.20 kgf/cm2
–1.00 to +10.00 bar
–14.6 to +145.0 psi
Orange LED
Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting
IP40 (IEC)
–10 to +50 °C +14 to +122 °F, Storage: –10 to +60 °C +14 to +140 °F (No dew condensation or icing allowed)
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each
Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) Within ±1 % F.S. (at +20 °C +68 °F)
Pressure port
Asia: M5 female thread + R (PT) 1/8 male thread (excluding DP-□-M(-P)), Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303)] ,
Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Weight
Accessories
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Other
Products
35 to 85 % RH, Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
Temperature characteristics
Material
674
Net weight: 40 g approx. [DP-10□-M(-P): 30 g approx.], Gross weight: 135 g approx. [DP-10□-M(-P): 125 g approx.]
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M” are short pressure port type. Model Nos. of North America type having the suffix “-P” are PNP output type.
3) Cannot be used at the same time.
DP-100
DP-M
675
Dual Display Digital Pressure Sensor
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
DP-10□
NPN output type
I/O circuit diagram
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Color code of connector attached cable
1
2
Tr1
ZD1
Tr2
ENDOSCOPE
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
5V
+
–
3
4
Terminal
No.
(Blue) 0 V
Designation
1
+V
2
Comparative output 1
3
Standard type: Comparative output 2
Multi-function type: Analog voltage output or External input
4
0V
Color code of connector attached cable
3
1kΩ
2
(White) Analog voltage output
or External input
Load
(Black) Comparative output 1
+
–
12 to 24 V DC
±10 %
100mA max.
ZD1
4
Internal circuit
(Blue) 0 V
Users’ circuit
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1 : PNP input transistor
Tr2 : NPN output transistor
DP-10□-P
PNP output type
I/O circuit diagram
Terminal arrangement diagram
Terminal No.
Standard type
Color code of connector attached cable
ZD1
Tr1
D
(Brown) +V
1
100mA max.
ZD2
Tr2
2
(Black) Comparative output 1
100mA max.
Load
3
(White) Comparative output 2
Load
(Blue) 0 V
+
–
Internal circuit
Users’ circuit
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: PNP output transistor
DP-100
Terminal No.
Sensor circuit
Multi-function type
D1
ZD1
Tr1
D2
3
4
Internal circuit
(Brown) +V
100mA max.
2
1kΩ
Tr2
Color code of connector attached cable
1
(Black) Comparative output 1
(White) Analog voltage output
Load
or External input
+
–
(Blue) 0 V
Users’ circuit
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1 : PNP output transistor
Tr2 : NPN input transistor
1
12 to 24 V DC
±10 %
4
Flow
DP-M
2
(Brown) +V
1
D2
Tr2
1
12 to 24 V DC
±10 %
Terminal No.
D1
Tr1
Pressure/
Head-separated
Other
Products
(White) Comparative output 2
Users’ circuit
Multi-function type
Sensor circuit
Pressure/
Digital Display
Load
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: NPN output transistor
UV
CURING
SYSTEMS
Selection
Guide
3
Internal circuit
LASER
MARKERS
PLC /
TERMINALS
100mA max.
4
Sensor circuit
STATIC
CONTROL
DEVICES
(Black)
Load
Comparative output 1
100mA max.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
(Brown) +V
ZD2
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Terminal No.
D
Sensor circuit
PRESSURE /
FLOW
SENSORS
Terminal arrangement diagram
Standard type
AREA
SENSORS
LIGHT
CURTAINS
DP-100 SERIES
12 to 24 V DC
±10 %
2
3
4
Terminal
No.
Designation
1
+V
2
Comparative output 1
3
Standard type: Comparative output 2
Multi-function type: Analog voltage output or External input
4
0V
Dual Display Digital Pressure Sensor
DP-100 SERIES
676
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
DP-11□-E-P-J
PNP output type
I/O circuit diagram
Terminal No.
Sensor circuit
Color code of connection cable
ZD1
Tr1
D
1
Tr2
4
(Black) Comparative output 1
100 mA max.
Load
2
(White) Comparative output 2
Load
(Blue) 0 V
Internal circuit
+
–
12 to 24 V DC
±10 %
Users’ circuit
Symbols … D: Reverse supply polarity protection diode
ZD1, ZD1: Surge absorption zener diode
Tr1, Tr2: PNP output transistor
Sensor circuit
D1
ZD1
1
AREA
SENSORS
Terminal
No.
Designation
1
+V
2
Standard type: Comparative output 2
Multi-function type: Analog voltage output or External input
3
0V
4
Comparative output 1
(Black) Comparative output 1
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
+
–
12 to 24 V DC
±10 %
STATIC
CONTROL
DEVICES
ENDOSCOPE
(Blue) 0 V
LASER
MARKERS
Users’ circuit
Symbols … D1, D2: Reverse supply polarity protection diode
ZD1: Surge absorption zener diode
Tr1: PNP output transistor
Tr2: NPN input transistor
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• The DP-100 series is designed for use with
non-corrosive gas. It cannot be used with
liquid or corrosive gas.
Connection
• Do not apply stress directly to
the connection cable leader or
to the connector.
LIGHT
CURTAINS
SIMPLE
WIRE-SAVING
UNITS
(Brown) +V
(White) Analog voltage output Load
2
or External input
3
Internal circuit
4
100 mA max.
4
D2
3
MICRO
PHOTOELECTRIC
SENSORS
Terminal No.
Color code of connection cable
Multi-function type
Tr2
2
(Brown) +V
3
1kΩ
1
100 mA max.
ZD2
Tr1
PHOTOELECTRIC
SENSORS
Terminal arrangement diagram
Standard type
LASER
SENSORS
Refer to General precautions.
Mounting
• The MS-DP1-1 sensor mounting bracket is available
separately, and it should be used for mounting. When
tightening the sensor to the sensor mounting bracket, use
a tightening torque of 0.5 N·m or less.
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-1)
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Flow
Other
Products
Connector
attached cable
[CN-14A(-R)-C□]
• The MS-DP1-2 panel mounting bracket (optional) and
the MS-DP1-3 front protection cover (optional) are also
available.
Front protection cover
MS-DP1-3(optional)
Conditions
• The line to connect with this sensor should be less than
30 m 98.425 ft.
FA
COMPONENTS
Pressure/
Head-separated
Sensor mounting bracket
MS-DP1-1 (Optional)
Conditions in use for CE conformity
• The DP-100 series is a CE conformity product complying
with EMC Directive. The harmonized standard with regard
to immunity that applies to this product is EN 61000-6-2
and the following condition must be met to conform to that
standard.
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Panel mounting bracket
MS-DP1-2(optional)
DP-100
DP-M
677
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Dual Display Digital Pressure Sensor
PRECAUTIONS FOR PROPER USE
Mounting
• The MS-DP1-4 panel mounting bracket is available when
switching from the DP2 / DP3 series.
DP2 / DP3
DP
2-2
0
ñ10
1
OUT
0-AD
J
2
MO
DE
Remove
Insert
DP-100
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
WIRE-SAVING
SYSTEMS
Pa
OUT
Remove
PRESSURE /
FLOW
SENSORS
SIMPLE
WIRE-SAVING
UNITS
1.3k
Front protective cover
DPX-04 (Optional)
can be installed on
MS-DP1-4.
LIGHT
CURTAINS
SENSOR
OPTIONS
DP-100 SERIES
Mounting holes
for DP2 / DP3 series
can be used as is.
Panel mounting bracket MS-DP1-4
• An conversion bushing is available for when using the
DP-10□-M short pressure port type. It can be used to
switch between this model and the DP2 / DP3 series. When
connecting to the pressure port, use a tightening torque of
M5 female thread
Rc1/8 female thread
1.0 N·m or less.
Refer to General precautions.
Piping
12 mm 0.472 in
• If connecting a commercially-available
spanner
coupling to the pressure port, attach a
12 mm 0.472 in spanner (14 mm 0.551
in spanner for DP-100-E type) to the
hexagonal section of the pressure port
to secure it, and tighten at a torque of
9.8 N·m or less. If it is tightened using
excessive torque, it may damage the
coupling or the pressure port.
In addition, wrap sealing tape around
the coupling when connecting it to prevent leaks.
• If connecting a commercially-available joint to the pressure
port of the DP-10□-M, hold the main unit in your hand to
steady it, and tighten to a torque of 1.0 N·m or less. If it is
tightened to an excessive torque, the joint or the main unit
may become damaged.
• If connecting a commercially-available joint to the pressure
port of the MS-DP1-7, tighten to a torque of 9.8 N·m or less.
14 mm 0.551 in
spanner
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
Conversion bushing MS-DP1-7
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
• The MS-DP1-F□ flat attachment is available.
If using the MS-DP1-F□ flat attachment (optional), install
by following the procedures given below.
1 Decide the direction of this product to mount with the sensor.
• The tightening torque should be 1 N·m or less when
connecting a coupling to the pressure port of MS-DP1-FM.
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Pressure port
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Coupling (Purchase separately.)
Pressure port
faces downward
Pressure port
faces leftward
Note: It is not possible to mount this product such
that the pressure port faces upward.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Pressure port
faces rightward
Pressure port
faces upward
• When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm
0.551 in spanner and make sure that the tightening
torque is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a
sealing tape on the coupling when connecting.
2 Mount
this product with the M3 female threads of the sensor
by using the attached M3 (length 8 mm 0.315 in) screws.
The tightening torque should be 0.5 N·m or less.
M3 female thread
Other
Products
M3 (length 8 mm 0.315 in)
screw (Accessory)
DP-100
DP-M
14 mm 0.551 in
spanner
M3 female thread
3 Mount
this product with the mounting surface by using the attached
M4 (length 20 mm 0.787 in) screws. The tightening torque should
be 1.2 N·m or less.
Groove Groove
Connector
Connector
attachedattached
cable cable
M420
(length
20 mm
M4 (length
mm 0.787
in)0.787 in)
screw (Accessory)
screw (Accessory)
Note: Take
Note:
care
Take
that
care
if the
thatcable
if thewith
cable
connector
with connector
is sticking
is sticking
out of the
outside
of the side
groove groove
of this product
of this product
when mounting,
when mounting,
the cable
themay
cable
disconnected.
may disconnected.
Note: Do not tighten the pressure port by holding the product with the spanner.
It may cause the product breakage.
Flat attachment
• Make sure to mount MS-DP1-F□ with the sensor properly.
If it is not mounted properly, air leakage may occur.
• Take care that the excessive mounting and dismounting of
this product may cause deterioration of the O-ring.
• If you touch the O-ring of MS-DP1-F□, or any scratch or
dust, etc. is attached to it, air leakage may occur and the
sensing performance may deteriorate.
Take sufficient care when using and storing MS-DP1-F□.
Dual Display Digital Pressure Sensor
PRECAUTIONS FOR PROPER USE
DP-100 SERIES
678
Refer to General precautions.
LASER
SENSORS
PRO mode
Others
• Use within the rated pressure range.
• Do not apply pressure exceeding the pressure
withstandability value. The diaphragm will get damaged
and correct operation shall not be maintained.
• Do not use during the initial transient time (0.5 sec. approx.)
after the power supply is switched on.
• Avoid dust, dirt, and steam.
• Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
• Do not insert wires, etc., into the pressure port. The diaphragm
will get damaged and correct operation shall not be maintained.
• Do not operate the keys with pointed or sharp objects.
RUN mode
• This is the normal operating mode.
Setting item
Description
Threshold value
setting
The threshold values for ON / OFF operation can be changed directly
by pressing the increment key (UP) and the decrement key (DOWN).
Zero-adjustment
function
This forces the pressure value display to be reset to zero when
the pressure port is open on the atmospheric pressure side.
Key lock function
Stops key operations from being accepted.
Peak hold /
bottom hold function
Displays the peak value and bottom value for fluctuating
pressure. The peak value appears in the main display,
and the bottom value appears in the sub display.
• If the mode selection key is pressed and held for 5 sec. in
RUN mode, the mode will switch to PRO mode.
• If the mode selection key is pressed while a setting
is being made, the mode will switch to RUN mode. In
this case, the settings that have been changed will be
entered.
Setting item
Sub display switching
Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
Display refresh rate
switching
Changes the display refresh rate for the
pressure value displayed in the main display.
Hysteresis fix value
switching
Sets the response time for EASY mode and
window comparator mode. (8 steps)
Linked display color
switching
(standard type only)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
ECO mode setting
Allows power consumption to be reduced by
dimming the display or turning it off.
Setting check code
Allows the setting details to be checked via
codes.
Setting copy mode
Allows the setting details for the master sensor
to be copied to slave sensors.
Reset setting
Resets the settings to the factory settings.
Code
Table of codes
Description
Sets the output mode for comparative output 1.
Comparative output 2 output mode
Sets the output mode for comparative output 2.
setting (standard type only)
Allows switching between analog voltage output and
auto-reference input / remote zero-adjustment input.
NO / NC switching
Sets normally open (NO) or normally closed (NC).
Response time setting
Sets the response time.
The response time can be selected from 2.5 ms,
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500
ms, 1,000 ms and 5,000 ms.
Display color switching
for main display
Unit switching
AREA
SENSORS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
Allows the color for the main display to be changed.
The colors can be set to “red / green” or “green /
red” to correspond to ON / OFF output, or it can
be fixed at “red” or “green” all the time.
Pressure unit can be changed.
1st digit
Comparative NO / NC
output 1
output mode switching
NO
EASY
NC
NO
Hysteresis
NC
NO
Window
comparator
NC
–
–
–
–
4th digit
Standard
type only
2nd digit
3rd digit
Standard type Multi-function
type
Comparative NO / NC Analog voltage Threshold Display
Display
output 2
value
output /
color for
output mode switching External input display
main display color linking
Comparative
voltage
OFF Analog
OFF
P-1, Lo-1 Red
output
output 1
Autowhen ON Comparative
NO
Hi-1
output 2
reference
EASY
Comparative
Remote
NC
output 1
zero-adjustment P-2, Lo-2 Green
Comparative
when
ON
–
NO
Hi-2
output 2
Hysteresis
Comparative
–
NC
ADJ. Always output 1
Comparative
red
–
–
NO
output 2
Window
Comparative
comparator
–
–
NC
Always output 1
Comparative
green
–
–
–
–
output 2
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Code
Analog voltage output /
external input switching
(multi-function type only)
MICRO
PHOTOELECTRIC
SENSORS
LASER
MARKERS
• If the mode selection key is pressed and held for 2 sec. in
RUN mode, the mode will switch to MENU SETTING mode.
• If the mode selection key is pressed while a setting is being
made, the mode will switch to RUN mode. In this case, the
settings that have been changed will be entered.
Comparative output 1
output mode setting
PHOTOELECTRIC
SENSORS
LIGHT
CURTAINS
Description
MENU SETTING mode
Setting item
FIBER
SENSORS
5th digit
Response time
2.5 ms
5 ms
10 ms
25 ms
50 ms
100 ms
250 ms
500 ms
1,000 ms
5,000 ms
6th digit
Unit switching
MPa
kPa
kgf/cm2
bar
psi
mmHg
inchHg
–
–
–
7th digit
Display refresh rate
250 ms
500 ms
1,000 ms
–
–
–
–
–
–
–
8th digit
ECO mode
OFF
STD
FULL
–
–
–
–
–
–
–
Other
Products
DP-100
DP-M
679
FIBER
SENSORS
LASER
SENSORS
Dual Display Digital Pressure Sensor
DP-100 SERIES
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
DP-10□
Sensor
PHOTOELECTRIC
SENSORS
30
1.181
MICRO
PHOTOELECTRIC
SENSORS
25.5
1.004
42.5
1.673
20
0.787
7.5 9.5
0.295 0.374
Connector
AREA
SENSORS
12
0.472
20
0.787
30
1.181
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
R (PT) 1/8
male thread
(North America: NPT 1/8)
1.5
0.059
INDUCTIVE
PROXIMITY
SENSORS
Europe
PARTICULAR
USE
SENSORS
M5 female thread
M3 female thread, 4 0.157 deep
Europe
10
7
0.394 0.276
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
14
0.551
G 1/8
male thread
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
DP-10□-M(-P)
Sensor
30
1.181
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
ø8.3
ø0.327
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
MACHINE
VISION
SYSTEMS
4.5
0.177
30
1.181
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
20
0.787
30
1.181
25.5
1.004
connector
M3 female thread,
4 0.157 deep
1.5
0.059
M5 female thread,
4 0.157 deep
DP-11□-E-P-J
UV
CURING
SYSTEMS
Sensor
30
1.181
25.5
1.004
47.5
1.870
20
0.787
7
0.276
9.5
0.374
30
1.181
Selection
Guide
Pressure/
Digital Display
20
0.787
4.5
0.177
Pressure/
Head-separated
1.5
0.059
Other
Products
15
0.591
CN-14A-C□ CN-14A-R-C□
DP-M
14
0.551
M3 female thread,
4 0.157 deep
7
0.276
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
• Length L
L
35
1.378
M8 connector
M5 female thread
G 1/8 male thread
Flow
DP-100
20
0.787
50
0.969
Model No.
8
0.315
8
0.315
ø3.7 ø0.146 cable
Length L
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
Sensor mounting bracket (Optional)
ø2.3
ø0.091
9.5
14.5
0.571 0.374
22
0.866
22
0.866
30
1.181
20
0.787
13
0.512
5.3
(0.209
)
R13
20
0.787 R0.512
5.5
0.217
20
0.787
AREA
SENSORS
14.5
0.571
4.2
0.165
2-ø3.5 ø0.138
LIGHT
CURTAINS
25.5
1.004
42.5
1.673
45
1.772
30
1.181 45
1.772
INDUCTIVE
PROXIMITY
SENSORS
12
0.472
30
1.181
15
0.591
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
PRESSURE /
FLOW
SENSORS
9.5
0.374
7.5
0.295
44
1.732
SIMPLE
WIRE-SAVING
UNITS
t2
t 0.079
MS-DP1-5
Sensor mounting bracket (Optional)
STATIC
CONTROL
DEVICES
R6.75
R0.266
ENDOSCOPE
29.5
1.161
20
0.787
4.5
0.177
16
0.630
ø4.5
ø0.177
8.5
0.335
13.5
0.531
20
0.787
LASER
MARKERS
28
1.102
PLC /
TERMINALS
30
1.181
4.5
0.177
44.5
30 1.752
1.181
20
0.787
HUMAN
MACHINE
INTERFACES
49.5
(1.949
)
ø4.5
ø0.177
20
0.787
29.5
1.161
30
1.181
MS-DP1-2 MS-DP1-3
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
ø8.3
ø0.327
20
49.5
0.787 28.5 1.949
1.122
t 1.5
t 0.059
2-ø3.5 ø0.138
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
1.5
0.059
4.5
0.177
FA
COMPONENTS
28
1.102
MACHINE
VISION
SYSTEMS
t 1.5
t0.059
53.5
2.106
UV
CURING
SYSTEMS
Panel mounting bracket (Optional), Front protection cover (Optional)
Assembly dimensions
Mounting drawing with DP-10□
Panel cut-out dimensions
Selection
Guide
When 1 unit is installed
Pressure/
Digital Display
Pressure/
Head-separated
0
31 −0.4
0
1.220 −0.016
39.3
( 1.547
)
34.5
1.358
(
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Assembly dimensions
Mounting drawing with DP-10□-M
34.5 20
1.358 0.787
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
1.5
0.059
30
1.181
22.75
0.896
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
2-R2.1 R0.083
9.5
0.374
2-R2.1 R0.083
FIBER
SENSORS
PHOTOELECTRIC
SENSORS
Assembly dimensions
Mounting drawing with DP-10□
1
0.039
4.2
0.165
680
The CAD data in the dimensions can be downloaded from our website.
MS-DP1-1
t2
t 0.079
DP-100 SERIES
7.2
0.283
11
0.433
18.3 7.5
0.720 0.295
Front
protection
cover
)
50
1.969
33.4
1.315
8.7
0.343
Flow
Other
Products
0
31 −0.4
0
1.220 −0.016
9.5
0.374
When “n” units are installed horizontally in series When “n” units are installed vertically in series
0
12
0.472
R(PT) 1/ 8
male thread
Panel thickness dimension
1 to 6 mm 0.039 to 0.236 in
31 −0.4
0
1.220 −0.016
31 1.220 × n + 3.5 0.138 × (n-1)
0
31 −0.4
0
1.220 −0.016
55 2.165
or more
31 1.220 × n + 3.5 0.138 × (n-1)
Connector
33.4
1.315
M5 female thread,
4 0.157 deep
(52 2.047 max)
View A
M3 female thread,
4 0.157 deep
Material: POM (Panel mounting bracket)
Polycarbonate (Front protection cover)
55 2.165
or more
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
DP-100
DP-M
681
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
(
42.7
1.681
40
1.575
30
1.181
)
(
Panel cut-out dimensions
9.7
0.382
36
1.417
26.5
1.043
6.5
0.256
3
0.118
)
56
2.205
36 +0.5
0
1.417 +0.020
0
Panel mounting
bracket body
Front protection cover (DPX-04)
8
0.315
Panel thickness dimension 1 to 3.2 mm
0.039 to 0.126 in
Panel mounting
bracket
MS-DP1-7
MEASUREMENT
SENSORS
M5 female
thread
80
3.150
36 +0.5
0
1.417 +0.020
0
Spacer
Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.
Material: Panel mounting bracket body ··· Nylon 6
Panel mounting bracket ··· Stainless steel (SUS304)
Spacer ··· Cold rolled carbon steel (SPCC)(Uni-chrome plated)
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Connector
R 1/ 8
male thread
12
0.472
42.7
1.681
40
30
1.575 1.181
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Panel mounting bracket (Optional)
Assembly dimensions
Mounting drawing with DP-10□
LIGHT
CURTAINS
INDUCTIVE
PROXIMITY
SENSORS
The CAD data in the dimensions can be downloaded from our website.
MS-DP1-4
AREA
SENSORS
PRESSURE /
FLOW
SENSORS
DP-100 SERIES
Conversion bushing (Optional)
15.8
0.622
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
14
0.551
3.5
0.138
0.5
( 0.020
)
11 0.433
7.8
0.307
M5 male thread
Gasket
8
0.315
10 0.394
Rc1/8 female thread
FA
COMPONENTS
Material: Brass (Nickel plated)
Weight: 10 g approx.
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
MS-DP1-FM
Assembly dimensions
Mounting drawing with DP-10□-M
Pressure/
Digital Display
44.5
(1.752
)
24
(0.945
)
Pressure/
Head-separated
Flow
Other
Products
DP-100
Flat attachment (Optional)
30
1.181
44.5
1.752
DP-M
2-ø4.3 ø0.169
20
0.787
24
0.945
30
1.181
52.5
( 2.067
)
24
(0.945
)
37
1.457
11.5
0.453
24
0.945
8.5 0.335
37
1.457
11.5
0.453
11
0.433
30
1.181
52.5
2.067
24
0.945
6.5 0.256
5.5 0.217 13.5
0.531
17.5
0.689
M5 female thread
Flat attachment (Optional)
Assembly dimensions
Mounting drawing with DP-10□-M
11
0.433
6.5 0.256
5.5 0.217
MS-DP1-FR/FN/FE
Material: Enclosure···Polybutylene
terephthalate (PBT)
(Glass fiber reinforced)
Pressure port···Stainless steel
(SUS303)
O-ring···Hydrogenated Nitrile
Butadiene Rubber
(H-NBR)
Weight: 15 g approx. (flat attachment only)
Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.
2-ø4.3
ø0.169
14
0.551
20
0.787
24
0.945
30
1.181
Product distinguishing mark
MS-DP1-FR: 0 line
MS-DP1-FN: 1 line
MS-DP1-FE: 2 line
17.5
0.689
8.5
0.335
Pressure port
G1/8 female thread (Note)
Material: Enclosure···Polybutylene terephthalate (PBT)
(Glass fiber reinforced)
Pressure port···Stainless steel (SUS303)
O-ring···Hydrogenated Nitrile
Butadiene Rubber (H-NBR)
Weight: 25 g approx. (flat attachment only)
Note: MS-DP1-FR has a
Rc1/8 female thread.
MS-DP1-FN has a
NPT1/8 female thread.
Two M3 (length 8 mm 0.315 in) screws, two M4 (length
20 mm 0.787 in) screws are attached.
682
MEMO