DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
Rev A
FEATURES
•
•
•
•
Quarter Brick Package
Wide Input Range
High Efficiency
No Minimum Load
Requirement
• Remote On/Off
• Over Load, Short Circuit, Over Voltage, and Over
Temperature Protection
• UL/cUL 60950-1 recognition (UL certificate), IEC/EN
60950-1 (CB-Report), EN 50155, IEC 60571
DESCRIPTION
The DCMQ75 series of DC/DC railway converters offers 75 watts of output power in a
2.28” x 1.45” x 0.50” quarter brick package. This series consists of single output
models with wide input range and high efficiency. Each model in this series has no
minimum load requirement, over load, short circuit, over voltage, and over temperature
protection as well as remote on/off. This series has UL/cUL 60950-1 recognition (UL
certificate), IEC/EN 60950-1 (CB-Report), EN 50155, IEC 60571 safety approvals.
Size: 2.28in x 1.45in x 0.50in
(57.9mm x 36.8mm x 12.7mm)
MODEL SELECTION TABLE
Model Number(1)
DCMQ75-72S05
DCMQ75-72S12
DCMQ75-72S15
DCMQ75-72S24
DCMQ75-110S05
DCMQ75-110S12
DCMQ75-110S15
DCMQ75-110S24
Input Voltage
Range
72VDC
(43~101VDC)
110VDC
(66~160VDC)
Output
Voltage
5VDC
12VDC
15VDC
24VDC
5VDC
12VDC
15VDC
24VDC
Input Current
Max. Output
Maximum
Current
Capacitive Load
No Load Max Load
50mA
1170mA
15000mA
25500µF
45mA
1132mA
6250mA
4400µF
45mA
1132mA
5000mA
2800µF
55mA
1145mA
3125mA
1100µF
40mA
766mA
15000mA
25500µF
35mA
749mA
6250mA
4400µF
35mA
749mA
5000mA
2800µF
50mA
758mA
3125mA
1100µF
Over Voltage
Protection
Efficiency
6.2VDC
15VDC
18VDC
30VDC
6.2VDC
15VDC
18VDC
30VDC
89%
92%
92%
91%
89%
91%
91%
90%
Reflected
Ripple Current
Output
Power
35mA
75W
35mA
75W
SPECIFICATIONS
All specifications are based on 25°C, Resistive Load, Nominal Input Voltage, and Rated Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
Min
Typ
Max
43
66
-0.7
-0.7
72
110
101
160
165
250
43
66
Unit
INPUT SPECIFICATIONS
Input Voltage Range
Input Surge Voltage (100ms. Max)
Start-Up Threshold Voltage
Under Voltage Shutdown
Input Filter
OUTPUT SPECIFICATIONS
Output Voltage
Voltage Accuracy
Line Regulation
Load Regulation
Output Power
Output Current
Minimum Load
Maximum Capacitive Load
Ripple & Noise (20MHz bandwidth)(2)
Transient Recovery Time(3)
Transient Response Deviation
Trim Up/Down Range
Start-Up Time
Temperature Coefficient
8/16/2016
72V Input Models
110V Input Models
72V Input Models
110V Input Models
72V Input Models
110V Input Models
72V Input Models
110V Input Models
Vin=Min. to Max. @Full Load
Io=0% to 100%
24V Output
Others
25% Load Step Change
25% Load Step Change
% of Nominal Output Voltage
All Models
40
63
Internal Pi Type
VDC
VDC
VDC
VDC
See Table
±1.0
%Vnom.
±0.2
%
±0.3
%
See Table
See Table
No Minimum Load Requirement
See Table
150
mVp-p
100
250
µsec
±3
±5
%
±10
%
0.35
S
±0.02
%/ºC
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 1 of 7
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
Rev A
SPECIFICATIONS
All specifications are based on 25°C, Resistive Load, Nominal Input Voltage, and Rated Output Current unless otherwise noted.
We reserve the right to change specifications based on technological advances.
SPECIFICATION
TEST CONDITIONS
REMOTE ON/OFF CONTROL
Converter On
Converter Off
Control Input Current (On)
Control Input Current (Off)
Control Common
Standby Input Current
PROTECTION
Short Circuit Protection
Over Load Protection
Over Temperature Protection
Over Voltage Protection
ENVIRONMENTAL SPECIFICATIONS
Min
Vctrl=5.0V
Vctrl=0V
Nominal Vin
Hiccup Mode 0.3Hz typ.
Hiccup
Base Plate
DCMQ75-75S12, 72S15
DCMQ75-72S24, 110S12, 110S15
DCMQ75-110S24
DCMQ75-72S05, 110S05
Storage Temperature
Thermal Impedance
Operating Humidity
Base-Plate Temperature Range
Lead Temperature
Cooling
Dry Heat
Damp Heat
Shock & Vibration Test
Fire Protection Test
MTBF
GENERAL SPECIFICATIONS
Typ. Efficiency
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
PHYSICAL SPECIFICATIONS
Weight
Natural Convection without Heatsink
Natural Convection with Heatsink
100LFM Convection without Heatsink
100LFM Convection with Heatsink
200LFM Convection without Heatsink
200LFM Convection with Heatsink
400LFM Convection without Heatsink
400LFM Convection with Heatsink
Non-Condensing
1.5mm from case for 10sec.
MIL-HDBK-217F@25ºC Full Load, Ground Benign
Automatic Recovery
150
+110
See Table
Dimensions (L x W x H)
Case Material
Top Side
Bottom Side
Base Material
Potting Material
SAFETY CHARACTERISTICS
Safety Approvals
EMI
ESD
Radiated Immunity
Fast Transient(5)
Surge(5)
Conducted Immunity
8/16/2016
-40
-40
-40
-40
-50
7.5
6.8
6.1
4.1
5.3
3.3
3.9
2.2
5
-40
Unit
Max.
Without
With
Heatsink Heatsink
56
61
49
55
43
48
36
42
+125
%
ºC
Unit
ºC
ºC
ºC/W
95
%RH
+105
ºC
260
ºC
Compliance to IEC/EN60068-2-1
Compliance to IEC/EN60068-2-2
Compliance to IEC/EN60068-2-30
Compliance to IEC/EN61373
Compliance to EN45545-2
143,800 Hours
@Max. Load
Inpuy/Output, Reinforced, Rated for 60 Seconds
Input/Output to Case
500VDC
100KHz, 1V
Max
3.5V~12V or Open Circuit
0V~1.2V or Short Circuit
0.5
mA
-0.5
mA
Referenced to Negative Input
2.5
mA
Min
Operating Temperature
Typ
See Table
320
3000
1500
1000
3000
KHz
VACrms
VDC
MΩ
pF
2.15oz (61g)
2.28in x 1.45in x 0.50in
(57.9mm x 36.8mm x 12.7mm)
Aluminum Frame with Black Anodized Coating
Aluminum Plate
Non-Conductive Black Plastic Base Plate
Epoxy (UL94-V0)
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB
Report), EN 50155, IEC 60571
Conduction & Radiation EN55022, EN5501, FCC part 15
EN61000-4-2
Air±8kV, Contact ±6kV
EN61000-4-3
10V/m
EN61000-4-4
±2kV
EN61000-4-5
±2kV
EN61000-4-6
10Vrms
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Class A
A
A
A
A
A
Page 2 of 7
Rev A
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
NOTES
1. Heatsink is available for models. To indicate heatsink for model, add -HS to model number.
2. Ripple & Noise measurement with a 1µF MLCC and a 10µF Tantalum Capacitor.
3. Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
4. Other inputs and outputs may be available, please contact factory.
5. To meet EN61000-4-4 & EN61000-4-5 by adding a capacitor across the input pins. Suggested capacitor: 470µF/200V.
6. Parallel a capacitor across the input pins under specification testing. Suggested capacitor: 68µF/200V.
7. Natural Convection is about 20LFM but is not equal to still air (0 LFM).
*Due to advances in technology, specifications subject to change without notice.
DERATING CURVES
DCMQ75-72S12, 72S15 Derating curve without Heatsink
DCMQ75-72S12, 72S15 Derating Curve with Heatsink
DCMQ75-110S12, 110S15, 72S24
Derating Curve without Heatsink
DCMQ75-110S12, 110S15, 72S24
Derating Curve with Heatsink
DCMQ75-110S24 Derating Curve Without Heatsink
DCMQ75-110S24 Derating Curve with Heatsink
8/16/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 3 of 7
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
Rev A
DCMQ75-72S05, 110S05 Derating Curve without Heatsink
DCMQ75-72S05, 110S05 Derating Curve with Heatsink
RECOMMENDED FILTER
Recommended Filter for EN 55011&55022, Class A; FCC part 15, Level A Compliance
Model Type
DCMQ75-72SXX
DCMQ75-110SXX
L1
450µH/450µH
C1
CHEMI-CON KXG Series
68µF/200V
C3
2200pF
3KV
C4
2200pF
3KV
C5
2200pF
3KV
C6
2200pF
3KV
MECHANICAL DRAWINGS
PIN CONNECTIONS
Pin
Function
1
+Vin
2
Remote On/Off
3
-Vin
4
-Vout
5
*-Sense
6
Trim
7
*+Sense
8
+Vout
*If remote sense is not used, the +sense should be connected to
+output and –sense should be connected to –output. Maximum
output deviation is 10% inclusive of trim.
All dimensions in mm (inches
Tolerance: X.X±0.5 (X.XX±0.02)
X.XX±0.25 (X.XXX±0.01)
Pin Diameter Ø 1.0±0.05 (0.04±0.002)
Pin Diameter Ø 1.5±0.05 (0.06±0.002)
8/16/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 4 of 7
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
Rev A
HEATSINK OPTIONS
Heatsink Material: Aluminum
Finish: Black Anodized Coating
Weight: 13g
Advantages of adding heatsink:
Improves heat dissipation and increases the stability and
reliability of the DC/DC converters at high operating
temperatures.
EXTERNAL OUTPUT TRIMMING
DCMQ75-XXS05 Trim Table
Trim Down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
138.88
62.41
3
Vox0.97
36.92
4
Vox0.96
24.18
5
Vox0.95
16.53
6
Vox0.94
11.44
7
Vox0.93
7.79
8
Vox0.92
5.06
9
Vox0.91
2.94
10
Vox0.90
1.24
%
Volts
KOhms
2
Vox1.02
47.76
3
Vox1.03
28.06
4
Vox1.04
18.21
5
Vox1.05
12.30
6
Vox1.06
8.36
7
Vox1.07
5.55
8
Vox1.08
3.44
9
Vox1.09
1.79
10
Vox1.10
0.48
%
Volts
KOhms
DCMQ75-XXS12 Trim Table
Trim Down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
413.55
184.55
3
Vox0.97
108.22
4
Vox0.96
70.05
5
Vox0.95
47.15
6
Vox0.94
31.88
7
Vox0.93
20.89
8
Vox0.92
12.80
9
Vox0.91
6.44
10
Vox0.90
1.35
%
Volts
KOhms
2
Vox1.02
157.50
3
Vox1.03
93.00
4
Vox1.04
60.75
5
Vox1.05
41.40
6
Vox1.06
28.50
7
Vox1.07
19.29
8
Vox1.08
12.37
9
Vox1.09
7.00
10
Vox1.10
2.70
%
Volts
KOhms
DCMQ75-XXS15 Trim Table
Trim Down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
530.73
238.61
3
Vox0.97
141.24
4
Vox0.96
92.56
5
Vox0.95
63.35
6
Vox0.94
43.87
7
Vox0.93
29.96
8
Vox0.92
19.53
9
Vox0.91
11.41
10
Vox0.90
4.92
%
Volts
KOhms
2
Vox1.02
189.89
3
Vox1.03
112.26
4
Vox1.04
73.44
5
Vox1.05
50.15
6
Vox1.06
34.63
7
Vox1.07
23.54
8
Vox1.08
15.22
9
Vox1.09
8.75
10
Vox1.10
3.58
%
Volts
KOhms
DCMQ75-XXS024 Trim Table
Trim Down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
598.66
267.78
3
Vox0.97
157.49
4
Vox0.96
102.34
5
Vox0.95
69.25
6
Vox0.94
47.19
7
Vox0.93
31.44
8
Vox0.92
19.62
9
Vox0.91
10.43
10
Vox0.90
3.08
%
Volts
KOhms
3
Vox1.03
128.31
4
Vox1.04
83.46
5
Vox1.05
56.55
6
Vox1.06
38.61
7
Vox1.07
25.79
8
Vox1.08
16.18
9
Vox1.09
8.70
10
Vox1.10
2.72
%
Volts
KOhms
Trim Up
Vout=
Ru=
Trim Up
Vout=
Ru=
Trim Up
Vout=
Ru=
Trim Up
Vout=
Ru=
8/16/2016
1
Vox1.01
106.87
1
Vox1.01
351.00
1
Vox1.01
422.77
1
Vox1.01
487.14
2
Vox1.02
218.02
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 5 of 7
Rev A
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
TEST SETUP
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin (4.7µH) and Cin (220µF, ESR < 1.0Ω at 100KHz) to simulate source
impedance. Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module,
measurement bandwidth is 0-500KHz.
Peak-to Peak Output Noise Measurement Test
Use a 1µF ceramic capacitor and a 10µF tantalum capacitor. Scope measurement should be made by using a BNC socket,
measurement bandwidth is 0-20MHz. Position the load between 50mm and 75mm from the DC/DC converter.
APPLICATION NOTES
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn
the power module on and off, the user must supply a switch to control the votlage between the on/off terminal and the –Vin terminal.
The switch can be an open collector or equivalent. A logic low is 0V to 1.2V. A logic high is 3.5V to 12V. the maximum sink current at
the on/off terminal (Pin 2) during a logic low is -500µA.
Overcurrent Protection
To provide hiccup mode prtection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and
can endure overload for an unlimited duration.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the
voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a
redundant voltage control that reduces the risk of output overvoltage. The OVP level can be found in the output data.
Output Ripple Reduction
A good quality low ESR cpacitor placed as close as practicable across the load will give the best ripple nad noise performance. To
reduce output ripple, it is recommended to use 4.7µF capacitors at the output.
Maximum Capacitive Load
The DCMQ75 series has limitation of maximum connected capacitance at the output. The power module may be operated in current
limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, aiflow over the module and board spacing.
To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept
below 105ºC, Tge derating curves are determined from measurements obtained in a test setup.
8/16/2016
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 6 of 7
Rev A
DCMQ75 SERIES
75 Watts
DC/DC Railway Converter
Single Output
COMPANY INFORMATION
Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development
engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008
certification is just one example of our commitment to producing a high quality, well-documented product for our customers.
Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely
with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide
ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your
future projects.
Contact Wall Industries for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
8/16/2016
(603)778-2300
(888)597-9255
(603)778-9797
[email protected]
www.wallindustries.com
37 Industrial Drive
Exeter, NH 03833
Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
Fax 603-778-9797
website: www.wallindustries.com • e-mail: [email protected]
Page 7 of 7
Similar pages