PAIRUI BBF Dc-dc converter Datasheet

DC-DC Converter
Bricks, Open/Enclosed
BBF SERIES, FULL BRICK, UP TO 700W
FEATURES:
5 years warranty
1500Vdc isolation voltage
Wide(2:1) input voltage range
Efficiency up to 94%
Operating temperature range -40°C to +100°C
Under voltage, over current, short circuit,
over voltage protection
Remote on/off
Adjustable output voltage
Input voltage
(Vdc)
Output voltage
(Vdc)
Output current
(A)
Efficiency
Typ.
24(18~36)
28.0
21.5
88%
BBF48-120V42
12.0
42.0
89%
BBF48-240V13
BBF48-240V26
24.0
12.5
85%
24.0
26.0
94%
BBF48-280V18
28.0
18.0
94%
BBF48-280V25
28.0
25.0
94%
Model
BBF24-280V22
48(36~72)
Notes: other input and output models may available on request.
ELECTRICAL
Input voltage range
24V
18-36Vdc
48V
36-72Vdc
ON: current operating on
Remote control
Current-model control
remote terminal
OFF: no current operating on
remote terminal
Output power
Input voltage range
Output voltage
Single output
Output voltage accuracy
Input voltage range
Output voltage adjustable
Negative logic
+10%
Line regulation
Full load
±0.2%
Load regulation
10%-100% full load
±0.5%
Dynamic response
(transient/recovery time)
300-700W
12/24/28Vdc
±1%
25%-50%-75% load capability
Ripple and noise
Parallel test, 20MHz wide range
Operating frequency
Typical value
www.pairuigroup.com
Page:
∆Vo/∆t: ±4.0%/500μs
240mVp-p max.
300KHz typ.
1/3
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BBF SERIES, FULL BRICK, UP TO 700W
ELECTRICAL
Isolation voltage
Input to output
1500Vdc
Input to case
1050Vdc
Output to case
500Vdc
Isolation resistance
---
100MΩ
Safety
---
EN-60950
Temperature coefficient
---
200ppm
Operating temperature range
Auxiliary heat sink
-40°C to +100°C
Storage temperature range
---
-40°C to +105°C
Over temperature protection
Typical
Under voltage protection
---
Yes
Over current protection
---
Yes
Short circuit protection
---
Yes
Over voltage protection
---
Yes
Relative humidity
---
95% max.
Packing
---
Hole package
MTBF
Bellcore TR-332, 25°C
105°C typ.
2*106Hrs
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
℃
MECHANICAL
CONNECTION
PCB LAYOUT
PIN #
SINGLE
1
-Vin
2
+Vin
3
-REM
4
+REM
567
GND
8 9 10
+Vo
11
AUX
12
IOG
13
PC
14
TRIM
15
+S
16
-S
Note:
* Unit is mm(inch).
www.pairuigroup.com
Page:
2/3
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BBF SERIES, FULL BRICK, UP TO 700W
DERATING CURVE
EFFICIENCY CURVE
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended.
The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended
capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended
0.1~1μF high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com
Page:
3/3
Date: 01/23/2014