AIMTEC AM30EW-2415S-NZ Continuous short circuit protection Datasheet

Series AM30EW-NZ
30 Watt | DC-DC Converter
Picture coming soon
FEATURES:
•
•
•
•
•
•
•
•
•
•
Efficiency up to 90%
Ultra-wide 4:1 Input range
No-load consumption ≤0.14W
Operating Temperature: -40oC to +75oC
Input under voltage lockout
On/Off Remote Control
Over Voltage Protection
I/Output Isolation 1500VDC
Over Current protection
Continuous Short Circuit protection
Models
Single output
Model
Input
Voltage
(V)
Max Input
current
Full/No load
(mA)
Output
Voltage
(V)
Output
Current
max (A)
Isolation
(VDC)
Max
Capacitive
Load(uF)
Efficiency
(%)
3.3
5
9
12
15
24
3.3
5
12
15
24
6
6
3.33
2.5
2
1.25
6
6
2.5
2
1.25
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
10000
10000
4700
2700
1680
680
10000
10000
2700
1680
680
85
88
88
90
90
90
87
88
89
89
89
AM30EW-2403S-NZ
9-36*
993/80
AM30EW-2405S-NZ
9-36*
1453/80
AM30EW-2409S-NZ
9-36*
1420/9
AM30EW-2412S-NZ
9-36*
1420/9
AM30EW-2415S-NZ
9-36*
1420/9
AM30EW-2424S-NZ
9-36*
1420/9
AM30EW-4803S-NZ
18-75
485/23
AM30EW-4805S-NZ
18-75
726/25
AM30EW-4812S-NZ
18-75
718/8
AM30EW-4815S-NZ
18-75
718/8
AM30EW-4824S-NZ
18-75
718/8
*At Input range 9-18VDC output power will be rated at 80%.
Add suffix “-K” for optional heat sink.
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
Typical
24
48
9-36
18-75
π(Pi) Network
10
Filter
Startup time
Absolute Maximum Rating (1sec max)
24
48
On/Off control
Input under voltage lockout
Input reflected current
24
48
Maximum
Units
VDC
ms
-0.7-50
-0.7-100
ON – open or 3.5-12VDC ; OFF – short to –Vin or 0-1.2VDC,
Idle current: 5 - 8mA
5.5-6.5
14-15.5
40
VDC
VDC
mA
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R13
Conditions
Typical
60 sec, 1mA
500VDC Isolation
I/O 100KHz/0.1V
1500
>1000
2000
Tel: +1 514 620 2722
1 of 5
Maximum
Units
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-NZ
30 Watt | DC-DC Converter
Output Specifications
Parameters
Conditions
Voltage accuracy
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Voltage adjustment range
Transient recovery time
Typical
±1
Zener Diode Clamp
110
110
Continuous, hiccup
Auto-Recovery
Full load, LL-HL
±0.2
0% to 100% load
±0.5
20MHz Bandwidth, 5% to 100% load
Transient recovery deviation
25% load step change
25% load step change: 3.3, 5, ±5Vout
25% load step change: others
±5
±3
Maximum
Units
±3
160
190
%
%
% of Io
±0.5
±1
±0.03
100
±10
500
±8
±5
% of Vin
%
o
%/ C
mV p-p
%
µS
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions
(L x W x H)
MTBF
Maximum soldering temperature
Conditions
Typical
100% load
See derating curve
300
Maximum
Units
100
KHz
o
C
o
C
o
C
-40 to +75
-55 to +105
Free air convection
95
Aluminum Alloy
26 without heat sink/ 34 with heat sink
Without heatsink
2 x 1 x 0.47 inches 50.8 x 25.4 x 11.8 mm
With heatsink
2 x 1 x 0.64 inches 50.8 x 25.4 x 16.3 mm
o
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C)
1.5mm from case for 10 sec
300
% RH
g
o
C
Environment Specification
Test
Vibration
Parameters
Test mode
Acceleration
Conditions
10-55Hz
10g, 30min, every axis tested
Safety Specifications
Parameters
Standards
www.aimtec.com
F 051e R13
IEC/EN/UL 60950-1 pending
Meet EN 55022, Class B, with external filter & EN 55024: 2010
IEC 61000-4-2, Contact ±4KV, Criteria B
IEC 61000-4-3, 10V/m, Criteria A
IEC 61000-4-4, ±2KV, Criteria B, with external filter
IEC 61000-4-5, ±2KV, Criteria B, with external filter
IEC 61000-4-6, 3Vrms, Criteria A
IEC 61000-4-29, 0-70%, Criteria B
Tel: +1 514 620 2722
2 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-NZ
4
1
2
5
Bottom View
3
6
2.54
(0.10)
4.10
(0.16)
11.80
(0.47)
10.16
(0.40)
(2.00)
10.16
(0.40)
Dimensions
50.80
2.54
(0.10)
Single
+Vin
-Vin
On/Off Control
+Vout
-Vout
Trim
25.40
(1.00)
Pin
1
2
3
4
5
6
10.16
(0.40)
Pin Out Specifications
5.08
(0.20)
5.08
(0.20)
30 Watt | DC-DC Converter
2.54
(0.10)
Notes:
All dimensions are typical in millimeters (inches).
Pin Pitch Tolerance ±0.10 (±0.004)
Case Tolerance ±0.50 (±0.02)
Trimming
Output voltage can be externally trimmed by utilizing the methods as shown below
Fixed Resistor
Variable Potentiometer
Leave open if not used.
AM30EW-xx03S-NZ
Trim down %
1
Vout (VDC)
3.27
Rt down (KΩ)
124.138
Trim up %
1
Vout (VDC)
3.33
Rt up (KΩ)
-556.59
2
3.23
73.217
2
3.37
194.738
3
3.2
53.983
3
3.4
89.364
4
3.17
41.497
4
3.43
55.050
5
3.14
32.737
5
3.47
34.131
6
3.1
24.449
6
3.5
25.350
7
3.07
19.839
7
3.53
19.357
8
3.04
16.148
8
3.56
15.006
9
3
12.236
9
3.6
10.773
10
2.97
9.856
10
3.63
8.367
AM20EW-xx05S-NZ
Trim down %
1
Vout (VDC)
4.95
Rt down (KΩ)
105.180
Trim up %
1
Vout (VDC)
5.05
Rt up (KΩ)
176.356
2
4.9
52.153
2
5.1
71.279
3
4.85
31.996
3
5.15
41.973
4
4.8
21.377
4
5.2
28.200
5
4.75
14.822
5
5.25
20.197
6
4.7
10.372
6
5.3
14.967
7
4.65
7.154
7
5.35
11.281
8
4.6
4.719
8
5.4
8.543
9
4.55
2.811
9
5.45
6.430
10
4.5
1.276
10
5.5
4.749
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
3 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-NZ
30 Watt | DC-DC Converter
AM20EW-xx09S-NZ
Trim down %
1
Vout (VDC)
8.91
Rt down (KΩ)
375.532
Trim up %
1
9.09
Vout (VDC)
2
8.82
207.429
2
9.18
3
8.73
139.156
3
9.27
4
8.64
102.145
4
9.36
5
8.55
78.924
5
9.45
6
8.46
62.996
6
9.54
7
8.37
51.392
7
9.63
8
8.28
42.562
8
9.72
9
8.19
35.616
9
9.81
10
8.1
30.011
10
9.9
Rt up (KΩ)
314.531
112.638
64.147
42.357
29.974
21.989
16.412
12.296
9.134
6.628
AM20EW-xx12S-NZ
Trim down %
1
Vout (VDC)
11.88
Rt down (KΩ)
496.091
Trim up %
1
Vout (VDC)
12.12
Rt up (KΩ)
706.435
2
11.76
301.451
2
12.24
158.920
3
11.64
212.527
3
12.36
83.878
4
11.52
161.585
4
12.48
54.074
5
11.4
128.573
5
12.6
38.076
6
11.28
105.441
6
12.72
28.095
7
11.16
88.332
7
12.84
21.274
8
11.04
75.163
8
12.96
16.316
9
10.92
64.715
9
13.08
12.551
10
10.8
56.223
10
13.2
9.594
AM20EW-xx15S-NZ
Trim down %
1
Vout (VDC)
14.85
Rt down (KΩ)
634.883
Trim up %
1
Vout (VDC)
15.15
Rt up (KΩ)
1460.098
2
14.7
400.637
2
15.3
192.573
3
14.55
288.513
3
15.45
96.641
4
14.4
222.758
4
15.6
61.354
5
14.25
179.536
5
15.75
43.016
6
14.1
148.959
6
15.9
31.781
7
13.95
126.187
7
16.05
24.191
8
13.8
108.568
8
16.2
18.720
9
13.65
94.532
9
16.35
14.590
10
13.5
83.086
10
16.5
11.361
AM20EW-xx24S-NZ, xx=24 or 48
Trim down %
1
2
Vout (VDC)
23.76
23.52
Rt down (KΩ) 1038.047 638.015
Trim up %
1
2
Vout (VDC)
24.24
24.48
Rt up (KΩ)
816.889 179.913
3
23.28
455.256
3
24.72
94.338
4
23.04
350.553
4
24.96
60.463
5
22.8
282.702
5
25.2
42.306
6
22.56
235.158
6
25.44
30.987
7
22.32
199.992
7
25.68
23.256
8
22.08
172.928
8
25.92
17.640
9
21.84
151.453
9
26.16
13.375
10
21.6
134
10
26.4
10.027
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
4 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM30EW-NZ
30 Watt | DC-DC Converter
Derating
Free Air Convection
55 º C without heat sink
NOTE: With operations at 12V nominal input (9-18VDC) the
output power will be rated at 80% only.
100
Output Power (%)
65 º C with heat sink
80
Safe Operating Area
60
40
20
0
- 40
- 20
0
20
45
40
55
60
75
80
100
Ambient Temperature º C
EMC recommended filter
CY1
1nF/2KV
LCM
1mH
F1
+Vin
MOV
C1
+Vo
C2
C3
-Vin
C4
DC-DC Converter
-Vo
CY1
1nF/2KV
Model
MOV
24 Vin
S14K35
48 Vin
S14K60
C1
330 µF /
50V
330 µF /
100V
C2 & C3
4.7 µF /
50V
2.2 µF /
100V
C4
220µF for 3.3, 5 & 9 V
output
100 µF for 12, 15 & 24 V
output
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
5 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages