ETC2 CTFCS6-15 Transformers chassis mount Datasheet

Transformers
Chassis Mount
Features:
•
•
•
•
•
•
Single 230 V primary windings
Double section metric bobbins
Power : 6 to 200 VA, 50 / 60 Hz
Temperature class : B (130°C)
Dielectric strength : 3,750 Vrms
Manufactured and tested in accordance with EN60950 and EN61558
Specifications:
Dimensions : Millimetres
Maximum winding temperature
Overall insulation rating
Flash test (isolation test)
Winding wire
Tape
Core
Finish
:
:
:
:
:
:
:
55°C
> 50 MΩ (at 500 V, 20°C)
Primary / secondary / lamination 2.4 kVrms
Polyurethane coated IEC317 grade 1
3M no 56 or 36M no 1350Y thermosetting
400 / 50
Ultimeg 3.72 clear
Dimension Table
Dimensions
VA
Rating
Reg%
A
B
C
D
E
6
24
55
68
37
45
36
12
16
20
12
74
90
50
60
50
9
94
106
65
79
45
52
53
F
G
H
I
J
K
Weight (g)
170
-
-
-
-
-
-
390
530
985
Dimensions : Millimetres
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
<Page 1>
20/12/11 V1.1
Transformers
Chassis Mount
Dimension Table
Dimensions
VA
Rating
Reg%
100
10
150
9
200
8
Tolerance
2
A
-
B
-
C
-
D
-
E
-
F
G
H
I
J
K
Weight (g)
45
57
57
89
75
65
1,550
68
72
56
102
85
85
2,750
±1
approximate
Dimensions : Millimetres
Specifications Table
Output Vac
Part Number
Transformer, 6 VA, 2 × 5 V
2×5
CTFCS6-5
Transformer, 6 VA, 2 × 6 V
2×6
CTFCS6-6
Transformer, 6 VA, 2 × 9 V
2×9
CTFCS6-9
2 × 12
CTFCS6-12
2 × 15
CTFCS6-15
Transformer, 6 VA, 2 ×18 V
2 × 18
CTFCS6-18
Transformer, 6 VA, 2 × 20 V
2 × 20
CTFCS6-20
Transformer, 6 VA, 2 × 24 V
2 × 24
CTFCS6-24
Transformer, 12 VA, 2 × 6 V
2×6
CTFCS12-6
Transformer, 12 VA, 2 × 9 V
2×9
CTFCS12-9
2 × 12
CTFCS12-12
Transformer, 12 VA, 2 × 20 V
2 × 20
CTFCS12-20
Transformer, 12 VA, 2 × 24 V
2 × 24
CTFCS12-24
Transformer, 20 VA, 2 × 6 V
2×6
CTFCS20-6
Transformer, 20 VA, 2 × 9 V
2×9
CTFCS20-9
Transformer, 20 VA, 2 × 12 V
2 × 12
CTFCS20-12
2 × 15
CTFCS20-15
Transformer, 20 VA, 2 × 18 V
2 × 18
CTFCS20-18
Transformer, 20 VA, 2 × 20 V
2 × 20
CTFCS20-20
Transformer, 20 VA, 2 × 24 V
2 × 24
CTFCS20-24
Transformer, 50 VA, 2 × 6 V
2×6
CTFCS50-6
Transformer, 50 VA, 2 × 12 V
2 × 12
CTFCS50-12
2 × 15
CTFCS50-15
Transformer, 50 VA, 2 × 18 V
2 × 18
CTFCS50-18
Transformer, 50 VA, 2 × 24 V
2 × 24
CTFCS50-24
Description
Transformer, 6 VA, 2 × 12 V
Transformer, 6 VA, 2 × 15 V
Transformer, 12 VA, 2 × 12 V
Transformer, 20 VA, 2 × 15 V
Transformer, 50 VA, 2 × 15 V
VA
6
12
20
50
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
<Page 2>
20/12/11 V1.1
Transformers
Chassis Mount
Specifications Table
Output Vac
Part Number
Transformer, 100 VA, 2 × 9 V
2×9
CTFCS100-9
Transformer, 100 VA, 2 × 12 V
2 × 12
CTFCS100-12
2 × 18
CTFCS100-18
Transformer, 100 VA, 2 × 24 V
2 × 24
CTFCS100-24
Transformer, 100 VA, 2 ×50 V
2 × 50
CTFCS100-50
Transformer, 150 VA, 2 × 12 V
2 ×12
CTFCS150-12
2 × 18
CTFCS150-18
Transformer, 150 VA, 2 × 24 V
2 × 24
CTFCS150-24
Transformer, 200 VA, 2 × 9 V
2×9
CTFCS200-9
2 × 18
CTFCS200-18
2 × 24
CTFCS200-24
2 × 50
CTFCS200-50
Description
Transformer, 100 VA, 2 × 18 V
Transformer, 150 VA, 2 × 18 V
Transformer, 200 VA, 2 × 18 V
Transformer, 200 VA, 2 × 24 V
Transformer, 200 VA, 2 × 50 V
VA
100
150
200
Important Notice : This data sheet and its contents (the "Information") belong to the members of the Premier Farnell group of companies (the "Group") or are licensed to it. No licence is granted for the use of
it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change without notice and replaces
all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any error in or omission from it or for any use
made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted.
Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising)
is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. Pro-POWER is the registered trademark of the Group. © Premier Farnell plc 2011.
www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
<Page 3>
20/12/11 V1.1
Similar pages