AIMTEC AMER150-CAZ-4 Constant current or constant voltage led driver or converter Datasheet

Click on Series name for product info on aimtec.com
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
 Constant Current or Constant Voltage LED
Driver or Converter
 Input range 90-305VAC/47-440Hz
 High Efficiency up to 89%
 115VAC Operating temperature -50 to 75°C
 230VAC Operating temperature -55 to 75°C
 Dimmable via resistive
 5 Year Limited Warranty
Models
Single output
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
AMER150-50300CAZ
150
36-50
0-3
90-305/47-440
130-430
AMER150-36420CAZ
150
24-36
0-4.16
90-305/47-440
130-430
AMER150-24630CAZ
151.2
12-24
0-6.3
90-305/47-440
130-430





Over Voltage Protection
Over Current Protection
Waterproof Case rated IP68
Power Factor Correction
Short Circuit Protection
Efficiency
(%)
Mode of Operation
Constant Current
Constant Voltage②
Constant Current
Constant Voltage②
Constant Current
Constant Voltage②
115
230
277
VAC
VAC
VAC
87
87
86
86
85
85
89
88
88
88
87
87
89
89
88
88
87
87
Add Suffix “-F” No dimming option
Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in this case.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMER150-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
①
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
www.aimtec.com
F 052.1e R3.Q
Conditions
Typical
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Maximum
2000
1000
900
50
75
90
0.25
3.5
0.98
0.94
0.92
3.5
900
Tel: +1 514 620 2722
1 of 10
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±3
Line regulation
LL-HL
±2
Load regulation
0-100% load
±3
200
Ripple & Noise ④
Hold-up time (min)
40
100-10
Current adjustment range⑤
④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
⑤Note: from 0% to 10% dimming adjustment signal instability may be present.
%
%
%
mV p-p
ms
%
Isolation Specifications
Parameters
Conditions
I/O
I/FG
O/FG
Tested voltage
Isolation resistance
Typical
Maximum
Units
3750
2000
500
VAC
VAC
VAC
MΩ
3sec
500 VDC
>1000
General Specifications
Parameters
Conditions
Typical
Switching frequency
Maximum
100
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
(See Derating Table)
Cold Start-up Time
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
Units
KHz
AMER150-50300CAZ
AMER150-36420CAZ
AMER150-24630CAZ
Refer to Constant Current vs. Constant Voltage Mode curve
Auto recovery
(115VAC)
-50 to +75
(230VAC)
-55 to +75
-55°C
3.07
4.27
6.37
oC
20
100
-55 to +95
±0.02
Free air convection
95
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG Input & 14AWG Output *20CM
900
7.13 x 2.32 x 1.85 inches
181.00 x 59.00 x 47.00 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
A
oC
Sec
oC
oC
% / oC
% RH
g
Safety Specifications
Parameters
Agency approvals
Standards
www.aimtec.com
F 052.1e R3.Q
UL, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68)
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
Tel: +1 514 620 2722
2 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Dimensions
Top View
181.00
(7.13)
4.00
(0.16)
41.00
(1.73)
27.00
(1.06)
8.00
(0.32)
End View
11.00
(0.43)
23.00
(0.91)
Side View
200.00
(8.00)
47.00
(1.85)
200.00
(8.00)
59.00
(2.32)
2.30
(0.09)
Input/Output Wires are 18 AWG 20cm
Measurements in Millimeters (inch)
Case Tolerance: ±0.5 (±0.02)
Wire connection:
Wire
Brown
Blue
Green
Red
Black
Blue (Dimming)
White (Dimming)
Connection
AC L
AC N
Ground
+V output
-V Output
+ Vs dimming
-Vs dimming
Analog (resistive) Dimming Application Circuit
Model Number
AMER150-50300CAZ
AMER150-36420CAZ
AMER150-24630CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
3 of 10
Maximum Pot
Value (kΩ)
16.71
26.70
11.47
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Analog (0-10V) Dimming Application Circuit
PWM (1KHz) Dimming Application Circuit
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
4 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Derating
230VAC
Efficiency vs. Input Voltage & Output Current (CC mode)
AMER150-50300CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
5 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
AMER150-36420CAZ
AMER150-24630CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
6 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
PFC value vs. Output Load Current (CC mode)
AMER150-50300CAZ
AMER150-36420CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
7 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
AMER150-24630CAZ
Constant Current vs. Constant Voltage Mode
AMER150-50300CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
8 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
AMER150-36420CAZ
AMER150-24630CAZ
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
9 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AMER150-CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Output Current vs. Radj
AMER150-50300CAZ
AMER150-36420CAZ
AMER150-24630CAZ
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052.1e R3.Q
Tel: +1 514 620 2722
10 of 10
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages